| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HS-TGA-101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | RT to 1150 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 10 µg |
| Heating/Cooling Rate | 1–80 °C/min |
| Maximum Sample Mass | 2 g |
| Baseline Drift | ≤10 µg |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HS-TGA-302 |
| Test Environment | Ambient Pressure |
| Sample Capacity | 1 sample per run |
| Instrument Type | General-purpose |
| Temperature Range | RT to 1300 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0–100 °C/min |
| Maximum Sample Mass | 5 g |
| Baseline Drift | ≤10 µg |
| Brand | Huicheng Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TGA-605 |
| Temperature Range | Ambient to 1550 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 5 g |
| Mass Sensitivity | 0.01 mg |
| Mass Repeatability | ±0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Baseline Drift | ±0.1 °C |
| Baseline Reproducibility | ±0.1 °C |
| Sampling Frequency | 0.05–10 Hz (programmable) |
| Dual-Temperature Sensing | Furnace & Sample |
| Control Modes | FTC (Fixed Temperature Control) & STC (Sample Temperature Control) |
| Programmable Temperature Stages | Up to 12 |
| Cycle Repetition | Up to 9999 cycles with auto-data retention |
| Atmosphere Control | Two independent gas lines with software-driven switching |
| Display | 7-inch 24-bit color LCD touchscreen |
| Cooling System | Integrated capillary water-circulation furnace jacket |
| Furnace Design | Modular ceramic insulation with dual-purge gas channels |
| Optional Exhaust Interface | Dedicated port for off-gas coupling to FTIR or MS |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3 Excellence Series |
| Temperature Range | −150 °C to 700 °C |
| Data Acquisition Rate | Up to 50 data points per second |
| Sensor Type | MultiSTARe™ DSC sensor with 56 or 120 thermocouple pairs (Au/Au-Pd) |
| Cooling Rate | 0.02 K/min to 50 K/min |
| Calibration | FlexCal® (fully automated, multi-point, reference-based) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1/1100 |
| Temperature Range | Ambient to 1100 °C |
| Temperature Accuracy | ±0.25 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| Baseline Repeatability | ±10 µg (full temperature range) |
| Sensor Type | Single-disk SDTA with Pt–Pt/Rh thermocouples |
| Modular Configuration | Optional autosampler, vacuum pump, MS/FTIR coupling, humidity control module |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1/1600 |
| Temperature Range | Ambient to 1600 °C |
| Temperature Accuracy | ±0.5 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| Baseline Repeatability | ±10 µg (full temperature range) |
| Sensor Type | Single-Pan SDTA (Simultaneous Differential Thermal Analysis) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 2 |
| Instrument Type | Universal |
| Temperature Range | RT to 1100 °C or 1600 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (model-dependent) |
| Heating/Cooling Rate | 0.02–150 K/min (standard furnace) / up to 250 K/min (fast furnace) |
| Dynamic Weighing Range | 1 g / 5 g (model-dependent) |
| Balance Accuracy | 0.005% |
| Balance Precision | 0.0025% |
| Resolution | Sub-microgram across full weighing range |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ Advanced |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02–150 K/min / 0.02–250 K/min |
| DSC Sensor | 6-pair Pt/Pt-Rh thermocouples |
| Simultaneous Measurement Capability | Yes |
| Modular Configuration | Standard |
| Compliance Ready | ASTM E1131, ISO 11358, USP <1163>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02–150 K/min / 0.02–250 K/min |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Sample Capacity | Multi-sample (with optional autosampler) |
| Instrument Type | Modular, general-purpose simultaneous TGA/DSC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ Standard |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02 to 150 K/min / 0.02 to 250 K/min |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Simultaneous Measurement Capability | Yes |
| Modular Configuration | Yes |
| Compliance Ready | ASTM E1131, ISO 11358, USP <1227>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 LF (Large Furnace) / TGA2 SF (Small Furnace) |
| Temperature Range | Up to 1100 °C (LF), Up to 600 °C (SF) |
| Temperature Accuracy | ±0.5 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.001–100 K/min |
| Furnace Type | Dual-furnace modular architecture |
| Compliance | ASTM E1131, ISO 11358, USP <41>, FDA 21 CFR Part 11 ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 |
| Temperature Range | RT to 1100 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (depending on balance module) |
| Heating/Cooling Rate | 0.02 to 150 K/min |
| Temperature Accuracy | ±1 K |
| Blank Curve Repeatability | < ±10 µg across full temperature range |
| Sensor Type | Single-pan SDTA (Simultaneous Differential Thermal Analysis) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 |
| Temperature Range | 30 °C – 1,100 °C |
| Sampling Rate | 10 data points/second |
| Atmosphere Control | Integrated Mass Flow Controller (MFC) for programmable gas switching |
| Buoyancy Correction | Automatic, model-based, no blank required |
| One-Click Method Launch | Yes |
| Optional Couplings | FTIR, MS, Micro GC, GC/MS |
| Sensor Output | Mass & Temperature |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TG 309 Libra Classic |
| Temperature Range | 10 °C to 1025 °C |
| Temperature Accuracy | ±0.15 K |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TG 309 Libra Select |
| Temperature Range | 10 °C to 1025/1100 °C |
| Temperature Accuracy | ±0.15 K |
| Heating/Cooling Rate | 0–200 K/min |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TG 309 Libra Supreme |
| Temperature Range | 10 °C to 1100 °C |
| Temperature Accuracy | ±0.15 K |
| Heating/Cooling Rate | 0–200 K/min |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TG209F1 Libra |
| Temperature Range | 10 °C to 1100 °C |
| Temperature Accuracy | ±0.2 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0–200 K/min |
| Cooling Time | <15 min (1100 °C → RT) |
| Vacuum Level | 10⁻² mbar |
| Maximum Sample Mass | 2 g |
| Furnace Material | Corrosion-Resistant Ceramic |
| Baseline Correction | BeFlat® Intelligent Baseline Compensation |
| Differential Thermal Signal | c-DTA® Function |
| Optional Automation | ASC Auto-Sampler (192 positions) |
| Optional Module | Temperature-Modulated TGA (TM-TG) |
| Brand | PerkinElmer |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Pyris™ |
| Pricing | Available upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TGA 4000 |
| Temperature Range | Ambient to 1000 °C |
| Balance Capacity | 1500 mg |
| Balance Resolution | 0.2 µg |
| Balance Accuracy/Precision | ±0.02% / ±0.01% |
| Heating Rate | 0.1–200 °C/min |
| Temperature Accuracy/Precision | ±1 °C / ±0.8 °C |
| Sample Pan Volume | 180 µL |
| Atmosphere Options | Static or dynamic, including N₂, Ar, He, CO₂, air, O₂, and other inert or reactive gases |
| Integrated Mass Flow Controller | Standard |
| Optional Autosampler | 45-position |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TGA 8000 |
| Instrument Type | General-Purpose |
| Temperature Range | –20 °C to 1200 °C |
| Heating Rate | 0.1–500 °C/min |
| Gas Control | Dual-path mass flow control (balance purge + sample purge), optional 3-gas mixing module |
| Automation | 48-position autosampler with AccuPik™ compatibility |
| 联用接口 | Integrated heated divert valve and sniffer for FTIR/MS/GC-MS coupling |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TGA-790 |
| Pricing | Upon Request |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 700 °C |
| Balance Sensitivity | ±0.01 µg |
| Temperature Calibration Method | Curie Point Reference |
| Heating/Cooling Rate | 0.01–50 °C/min |
| Mass Range | ±200 mg |
| Mass Resolution | ±0.02 µg |
| Atmosphere Control | Dual Independent Mass Flow Controllers (MFCs), Software-Programmable Gas Switching |
| Crucible Options | Alumina, Platinum |
| Furnace Cooling | Water-Cooled |
| Furnace Liner | Dust-Free Recirculating Cooling System |
| Power Supply | 220 V, 50/60 Hz |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | RZY-1 / RZY-2 |
| Price Range | USD 7,000 – 14,000 |
| Temperature Range | Ambient to 1400 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 1–50 °C/min |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | YT-TCD-101 |
| Temperature Range | Ambient to 1150 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating Rate | 1–80 °C/min |
| Cooling Time | 15 min (from 1000 °C to 100 °C) |
| Balance Capacity | 1 mg–2 g (extendable to 30 g) |
| Balance Resolution | 0.1 µg |
| Isothermal Hold Duration | 0–300 min (user-configurable) |
| Atmosphere Control | Dual-gas inlet with mass flow control (inert, oxidizing, reducing, static, dynamic) |
| Data Interface | RS-232 |
| Software | Integrated TGA analysis suite with automated curve recording, baseline correction, derivative (DTG) calculation, kinetic modeling (e.g., Kissinger, Ozawa), and GLP-compliant reporting |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Zhonglu |
|---|---|
| Model | TGA-1250Q |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Temperature Range | Ambient to 1350 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Resolution | 0.1 °C |
| Dynamic Weighing Range | 0.01 mg to 30 g |
| Balance Sensitivity | 0.1 μg |
| Mass Accuracy | ±0.00001 g |
| Heating/Cooling Rate | 1–80 °C/min |
| Maximum Sample Mass | 30 g |
| Baseline Repeatability | 25 ppm/10 °C |
| Baseline Drift | 25 ppm/10 °C |
| Atmosphere Control | Dual-gas inlet with mass flow control (inert, oxidizing, reducing, static/dynamic) |
| Cooling Time | ≤15 min (1000 °C → 100 °C) |
| Data Interface | RS-232 |
| Compliance | Patented in China (CN Patent No. disclosed upon request) |