Thermomechanical Analyzer
Filter
Showing all 22 results
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | MCR 703 MultiDrive |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −160 °C to +1000 °C |
| Frequency Range | 2 × 10⁻⁸ Hz to 200 Hz |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Model | TMA7100 / TMA7300 |
| Temperature Range | –170 °C to 600 °C (TMA7100) |
| Displacement Range | ±5 mm |
| Sensitivity (RMS Noise) | 0.005 µm / Resolution: 0.01 µm |
| Load Range | ±5.8 N (Resolution: 9.8 µN) |
| Heating Rate | 0.01–100 °C/min |
| Sample Max Dimensions | Ø10 mm × 25 mm (cylindrical) or 5 mm × 1 mm × 25 mm (film) |
| Probe Mounting | Cantilever-type |
| Atmosphere Control | Ambient, inert gas, vacuum (~1.3 Pa), optional humidity & swelling modules |
| Load/Displacement Control Modes | Constant force, constant rate, oscillatory (0.001–1 Hz), multi-step sequences (up to 40 steps) |
| Optional Cooling | Automated LN₂ cooling (–150 °C to 600 °C), electronic cooler (–60 °C to 450 °C), forced-air cooling (RT–600 °C), LN₂ Dewar kit (–170 °C to 600 °C) |
| Sample Tube Materials | Quartz (TMA7100), Alumina (TMA7300) |
| Probe Types | Expansion/compression quartz, penetration (standard & conical), tensile (quartz & metal), bending, sapphire dilatometry |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | VHF104 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −50 to 110 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–10 °C/min |
| Frequency Range | 100–10,000 Hz |
| Force Range | ±150 N |
| Displacement Range | ±10,000 µm |
| Strain Range | 10⁻⁶–30% |
| Deformation Modes | Tension, Compression, Annular Shear |
| Standard Masses | 5, 10, 20, 40, 80, 200 g |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DMA/SDTA861e |
| Temperature Range | −150 to 500 °C |
| Temperature Accuracy | ±0.5 °C |
| Force Range | 0.001–40 N |
| Displacement Range | ±1.6 mm |
| Frequency Range | 0.001–1000 Hz |
| Tan δ Range | 0.0001–100 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DMA1 |
| Temperature Range | −190 °C to 600 °C |
| Force Range | ±0.001 N to ±10 N |
| Displacement Range | ±1 mm |
| Frequency Range | 0.001 Hz to 300 Hz |
| Stiffness Range | 50 N/m to 10⁵ N/m |
| Tan δ Range | 0.0001 to 50 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TMA/SDTA 2+ IC/600 / LF/1100 / LN/600 |
| Temperature Range | –80 to 600 °C |
| Temperature Accuracy | ±0.005 °C |
| Force Range | –0.1 to 1 N |
| Displacement Resolution | 0.5 nm |
| Frequency Range | 0.01–1 Hz |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | LF/1100, HT/1600, IC600, LN600 |
| Temperature Range | –150 °C to 1600 °C |
| Temperature Accuracy | ±0.005 °C |
| Force Resolution | 0.01–1 Hz (dynamic frequency range) |
| Displacement Range | 20 mm |
| Length Resolution | 0.5 nm |
| Operating Modes | Compression, Tension, Penetration, Expansion |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TMA/SDTA840, TMA/SDTA841e |
| Temperature Range | −150–600 °C (TMA/SDTA841e), RT–1100 °C (TMA/SDTA840) |
| Temperature Accuracy | ±0.25 °C |
| TMA Resolution | 1 nm (TMA/SDTA841e), 10 nm (TMA/SDTA840) |
| Measurement Modes | Expansion, Penetration, Bending, Tension, Dynamic Load TMA (DLTMA) |
| SDTA Capability | Yes |
| Environmental Control | Hermetic sample chamber |
| Coupling Options | MS, FTIR |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TT DMA |
| Temperature Range | −190 °C to 600 °C |
| Frequency Range | 0.001 Hz to 1000 Hz |
| Fixture Configurations | Dual-cantilever, single-cantilever, 3-point bending, shear, tension, compression |
| Operating Modes | Creep, constant-force (TMA), stress–strain, stress relaxation, isothermal, step-isothermal, multi-ramp thermal profiles |
| Environmental Options | Humidity chamber (up to 85 °C / 85 % RH), liquid immersion cell, gas purge (N₂, air, Ar) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DMA 303 Eplexor |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −170 °C to 800 °C |
| Temperature Accuracy | ±0.1 °C |
| Force Range | 1 mN to 50 N |
| Displacement Range | 30 mm |
| Frequency Range | 0.001 Hz to 150 Hz |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | NETZSCH GABO EPLEXOR |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –160 °C to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Static Force Range | up to 500 N (optional 1500 N) |
| Dynamic Force Range | ±25 N, ±100 N, ±150 N, or ±500 N |
| Displacement Range | 60 mm |
| Frequency Range | 0.01 Hz to 100 Hz (optional: 0.0001 Hz and 200 Hz) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | NETZSCH-GABO METER |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | RT to 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Maximum Applied Force | 5000 N |
| Displacement Range | 50 mm |
| Frequency Range | 0.1–50 Hz |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | TMA 4000 SE |
| Temperature Range | –150 to 1700 °C |
| Temperature Accuracy | ±0.1 °C |
| Force Range | 0–4.9 N |
| Displacement Range | ±2.5 mm |
| Dynamic Frequency Range | 0.01–0.5 Hz |
| Measurement Modes | Expansion, Compression, Tension, Penetration, Bending, Dynamic Oscillation, Curing |
| Load Profiles | Constant Force, Sinusoidal (0.01–0.5 Hz), Triangular (0.01–0.2 Hz), Rectangular (0.01–0.1 Hz), Ramp Force (0–0.49 N/min) |
| Deformation Modes | Constant Strain, Strain Ramp (0–50 mm/min), Combined Modes |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TMA 402 F1 Hyperion |
| Temperature Range | −150 °C to 1550 °C (with interchangeable furnaces) |
| Temperature Accuracy | ±0.1 °C |
| Force Range | ±3 N |
| Displacement Range | ±2.5 mm |
| Displacement Resolution | 1.25 nm |
| Force Resolution | 0.01 mN |
| Heating Rate | 0–50 °C/min |
| Vacuum Level | 10⁻⁴ mbar |
| Measurement Atmospheres | Oxidizing, Reducing, Inert, Vacuum |
| Dual-Furnace Capability | Yes |
| Compatible with DSC/STA Furnaces | Yes |
| Dynamic Force Mode | Optional |
| Rate-Controlled Sintering (RCS) | Optional |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TMA 402 F3 Hyperion |
| Temperature Range | -150°C to 1550°C |
| Temperature Accuracy | ±0.1°C |
| Force Range | ±3 N |
| Displacement Range | ±2.5 mm |
| Displacement Resolution | 0.125 nm |
| Force Resolution | 0.01 mN |
| Heating Rate | 0–50°C/min |
| Measurement Atmosphere | Oxidizing, Reducing, Inert, Vacuum (down to 10⁻⁴ mbar) |
| Dual-Furnace Capability | Yes |
| Compatible Furnaces | Interchangeable with DSC and STA systems |
| Optional Modes | Dynamic Force, Rate-Controlled Sintering (RCS), Compression/Indentation/Bending/Tension |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Model | DMA 8000 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –196 °C to 600 °C (with LN₂ cryogenic cooling) |
| Frequency Range | 0.01–300 Hz |
| Cooling Rate | ≤15 min from ambient to –190 °C |
| Liquid Nitrogen Consumption | ~1 L per typical low-temperature DMA run |
| Sample Modes | Dual/Triple Cantilever, 3-Point Bending, Tension, Compression, Shear, and TMA Mode |
| Humidity Control Range | 10–90 % RH (optional humidity generator) |
| Optical Access | Quartz furnace viewport for in-situ visual monitoring and UV-curable sample testing |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TMA 4000 |
| Pricing | Available Upon Request |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | TMA8311 |
| Maximum Measurement Temperature | 1500 °C |
| Measurement Principle | Dual-rod Differential Dilatometry |
| Instrument Type | Thermomechanical Analyzer (TMA) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | 96line TMA |
| Instrument Type | Thermomechanical Analyzer |
| Temperature Range | Ambient to 2100 °C |
| Displacement Range | ±2 mm |
| Maximum Force | 1.5 N (electromagnetically controlled) |
| Sample Dimensions | L = 50 mm, Ø = 18 mm (recommended Ø = 15 mm) |
| Displacement Resolution | 1.6 nm RMS |
| Displacement Noise | 10 nm RMS |
| Specific Noise | 0.2 × 10⁻⁶ |
| Probe Types | Al₂O₃ (up to 1750 °C), Graphite (≥1750 °C) |
| Probe Geometry | Spherical-tip compression probe |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TMA-60/60H |
| Temperature Range | Ambient to 1000 °C / 1500 °C (optional cryo stage down to −150 °C) |
| Displacement Range | ±5 mm |
| Load Range | ±5 N |
| Sample Dimensions | Ø8 mm × 20 mm (cylindrical) or 5 mm (W) × 1 mm (T) × 20 mm (L) (rectangular) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Compliance | ASTM D4065, ASTM D7028, ISO 6721, ISO 11359, USP <1031> |
| Cooling Range | –100 °C to 600 °C |
| Force Range | 0.1 mN to 18 N |
| Displacement Resolution | 0.1 nm over 25 mm dynamic range |
| Environmental Options | Dual configurable environmental chambers (inert gas, humidity, vacuum) |
| Control Architecture | Non-contact voice-coil motor with continuous force control |
| Bearing System | Low-compliance air bearing |
| Strain Sensing | Direct optical encoder-based strain measurement |
| Software Platform | TRIOS v5.x with 21 CFR Part 11 compliant audit trail and GLP/GMP-ready workflows |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Techcomp RJY-1P |
| Instrument Type | Static Thermomechanical Analyzer (TMA) |
| Temperature Range | Ambient to 1000 °C |
| Temperature Accuracy | ±0.1 °C |
| Applied Load Range | Up to 250 g (static force) |
| Displacement Measurement Range | 0–2500 µm |