Thermometer
Filter
Showing all 18 results
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | AR-6500H / AR-6501H |
| Measurement Principle | Radiation-based (Infrared) + Contact (Thermocouple) |
| Measurement Modes | Non-contact IR + K-type thermocouple contact |
| Temperature Range (IR) | –50.0 to 500.0 °C (AR-6500H), 0 to 1200 °C (AR-6501H) |
| Temperature Range (Contact) | –50.0 to 500.0 °C (K-type, ≤500 Ω) |
| Resolution | 0.1 °C (–50.0 to 525.0 °C display range), 1 °C (up to 1250 °C) |
| Accuracy (IR, AR-6500H) | ±3 °C (<0 °C), ±2 °C (0–250 °C), ±0.8% of reading +1 digit (250–500 °C) |
| Accuracy (Contact, K-type) | ±(0.05% of reading + 0.1 °C) ±1 digit |
| Emissivity Adjustment Range | 0.10–2.00 (0.01 step) |
| Spectral Response | 8–14 µm |
| Detector | Thermopile |
| Response Time | ≈300 ms |
| Laser Targeting | Integrated Class II red laser (650 nm) |
| Repeatability | ±0.4% of reading +1 digit |
| Reference Junction Compensation Accuracy | ±0.2 °C (at 25 °C ±10 °C) |
| Temperature Coefficient | ±0.01% / °C of measured range |
| Analog Output | –1 mV/°C (optional, sensor sold separately) |
| Output Accuracy | ±(0.15% FS + 1 mV) at 25 °C ±5 °C |
| Power | Rechargeable Ni-Cd battery |
| Operating Time | >30 hours per full charge (varies with usage) |
| Operating Environment | 0–40 °C, 0–80% RH (non-condensing) |
| Storage Environment | –20–50 °C, 0–85% RH (non-condensing) |
| Dimensions | As per manufacturer’s mechanical drawing |
| Weight | Approx. 400 g |
| Compliance | IEC 60584-1:2013 (K-type linearization), CE marking, RoHS compliant |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9055 |
| Temperature Measurement Principle | K-type Thermocouple |
| Measurement Method | Contact |
| Temperature Range | −50 to +350 °C (short-term up to +500 °C) |
| Resolution | 0.1 °C |
| Accuracy | ±1 °C (−50 to +99.9 °C), ±1 % of reading (remaining range) |
| Stability | ±1 °C (−50 to +99.9 °C), ±1 % of reading (remaining range) |
| Response Time (t₉₉) | 10 s in water |
| Weight | 80 g |
| Dimensions (L×W×H) | 270 × 40 × 70 mm |
| Probe Sheath Length | 200 mm |
| Probe Tip Length | 4 mm |
| Probe Rod Diameter | 3 mm |
| Display | Single-line LCD |
| Operating Temperature | 0 to +40 °C |
| Storage Temperature | −20 to +70 °C |
| Housing Material | ABS |
| Power Supply | 3 × AAA batteries (rechargeable) |
| Battery Life | Up to 1000 h |
| CE Marking | 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 1108 |
| Temperature Measurement Principle | NTC Thermistor |
| Measurement Type | Contact |
| Temperature Range | −50 to +150 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.2 °C (−20 to +80 °C), ±0.3 °C (remaining range) |
| Stability | Compliant with HACCP and EN 13485 requirements |
| Operating Environment | −20 to +50 °C |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 7207 |
| Temperature Measurement Principle | Resistance Thermometry (Pt100/NTC) |
| Measurement Method | Contact |
| Temperature Range (NTC) | -50 to +150 °C |
| Temperature Range (Pt100) | -100 to +800 °C |
| Resolution | 0.1 °C |
| Accuracy (NTC) | ±0.2 °C (-25 to +40 °C) |
| Accuracy (Pt100) | ±0.2 % of reading (200 to +800 °C) |
| Stability | ±0.2 °C (typical, across most operating range) |
| Display | Backlit LCD |
| Dimensions | 182 × 64 × 40 mm |
| Weight | 171 g |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -30 to +70 °C |
| Enclosure Material | ABS |
| IP Rating (with optional protective sleeve) | IP65 |
| Power Supply | 9 V alkaline battery |
| Battery Life | Up to 70 hours |
| Included | Instrument, 9 V battery, calibration certificate |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9055 |
| Temperature Measurement Principle | K-Type Thermocouple |
| Measurement Method | Contact |
| Temperature Range | −50 to +350 °C (short-term up to +500 °C) |
| Resolution | 0.1 °C |
| Accuracy | ±1 °C (−50 to +99.9 °C), ±1 % of reading (remaining range) |
| Stability | ±1 °C (−50 to +99.9 °C), ±1 % of reading (remaining range) |
| Response Time t₉₉ | 10 s (in water) |
| Weight | 80 g |
| Dimensions (L×W×H) | 270 × 40 × 70 mm |
| Operating Temperature | 0 to +40 °C |
| Storage Temperature | −20 to +70 °C |
| Probe Sheath Length | 200 mm |
| Probe Tip Length | 4 mm |
| Probe Rod Diameter | 3 mm |
| Display | Single-line LCD |
| Housing Material | ABS |
| Power Supply | 3 × AAA batteries |
| Battery Life | Up to 1000 h |
| CE Marking | 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9056 |
| Temperature Measurement Principle | K-type Thermocouple |
| Measurement Method | Contact |
| Temperature Range | -50 to +350 °C (short-term up to +500 °C) |
| Resolution | 0.1 °C |
| Accuracy | ±(1 °C ±1 % of reading) |
| Stability | ±(1 °C ±1 % of reading) |
| Response Time (t₉₉) | 5 s |
| Weight | 80 g |
| Dimensions (L×W×H) | 220 × 40 × 70 mm |
| Operating Temperature | 0 to +40 °C |
| Storage Temperature | -20 to +70 °C |
| Probe Sheath Length | 150 mm |
| Probe Tip Length | 40 mm |
| Probe Stem Diameter | 3 mm |
| Probe Head Diameter | 12 mm |
| Display | Single-line LCD |
| Battery | 3 × AAA (rechargeable) |
| Battery Life | ~1000 h |
| Auto Power-off | After 10 min idle |
| Housing Material | ABS |
| Color | Black |
| Compliance | CE 2004/108/EC |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9221 |
| Temperature Measurement Principle | Thermocouple (Type K) |
| Measurement Method | Contact |
| Temperature Range | -50 to +1000 °C |
| Resolution | 0.1 °C (-50 to +199.9 °C), 1 °C (remaining range) |
| Accuracy | ±(0.5 °C + 0.3 % of reading) (-40 to +900 °C), ±(0.7 °C + 0.5 % of reading) (remaining range) |
| Stability | Same as accuracy specification |
| Operating Environment | -20 to +50 °C |
| Weight | 171 g |
| Dimensions | 182 × 64 × 40 mm |
| Power Supply | 9 V battery |
| Battery Life | 200 h (probe connected, backlight off), 68 h (probe connected, backlight on) |
| IP Rating | IP65 |
| Housing Material | ABS |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9255 |
| Temperature Measurement Principle | Thermocouple (Type K) |
| Measurement Method | Contact |
| Temperature Range | -50 to +1000 °C |
| Resolution | 0.1 °C (-50 to +199.9 °C), 1 °C (remaining range) |
| Accuracy | ±(0.5 °C + 0.3 % of reading) (-40 to +900 °C), ±(0.7 °C + 0.5 % of reading) (remaining range) |
| Stability | Identical to accuracy specification |
| Operating Environment | -20 to +50 °C |
| Dimensions | 182 × 65 × 40 mm |
| Weight | 171 g |
| Power Supply | 9 V battery |
| Battery Life | 200 h (backlight off, probe connected), 68 h (backlight on, probe connected) |
| Housing Material | ABS |
| Protection Rating (with optional protective sleeve) | IP65 |
| Channel Count | 1-channel |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9261 |
| Temperature Measurement Principle | Thermocouple (Type T, Type K compatible) |
| Measurement Method | Contact |
| Temperature Range | -50 to +400 °C |
| Resolution | 0.1 °C (-50 to +199.9 °C), 1 °C (remaining range) |
| Accuracy | ±0.3 °C (-20 to +70 °C) |
| Stability | ±0.3 °C (-20 to +70 °C) |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| IP Rating | IP65 (with optional protective sleeve) |
| Dimensions | 177 × 64 × 40 mm |
| Weight | 182 g (incl. 9 V battery) |
| Battery Life | 200 h (backlight off), 68 h (backlight on) |
| Compliance | EN 13485, HACCP principles, FDA-relevant food safety practices |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9261 |
| Temperature Measurement Principle | Thermocouple (Type T & K) |
| Measurement Method | Contact |
| Temperature Range | -50 to +400 °C |
| Resolution | 0.1 °C (-50 to +199.9 °C), 1 °C (remaining range) |
| Accuracy | ±0.3 °C (-20 to +70 °C) |
| Stability | ±0.3 °C (-20 to +70 °C) |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| IP Rating | IP65 (with optional protective sleeve) |
| Dimensions | 177 × 64 × 40 mm |
| Weight | 182 g (incl. 9 V battery) |
| Battery Life | 200 h (backlight off), 68 h (backlight on) |
| Compliance | EN 13485, HACCP-ready |
| Data Logging | Max/Min auto-capture, user-defined alarm thresholds with audible alert |
| Brand | Vcam |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | I606L |
| Pricing | Upon Request |
| Measurement Method | Contact |
| Temperature Range | 0–500 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.1 °C |
| Brand | Vcam |
|---|---|
| Model | I608L |
| Channels | 8 |
| Measurement Principle | Thermocouple-Based Contact Sensing |
| Temperature Range | 0–500 °C |
| Resolution | 0.1 °C |
| Operating Ambient | 0–50 °C (instrument), 0–500 °C (probe) |
| Display | Integrated High-Contrast LCD Screen |
| Data Interface | USB 2.0 + Optional Wi-Fi Module |
| Compliance | CE, RoHS, ISO/IEC 17025-Compatible Calibration Traceability |
| Software Platform | VcamTempSuite v4.2 (Windows 10/11, x64) |
| Brand | Vcam |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | I7 Series Furnace Temperature Profiling System |
| Temperature Measurement Principle | Thermocouple-Based |
| Measurement Method | Contact |
| Temperature Range | −50 °C to 700 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.5 °C |
| Brand | Vcam |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | iVacuum |
| Pricing | Available Upon Request |
| Temperature Measurement Principle | Thermocouple-Based |
| Measurement Method | Contact |
| Temperature Range | -50 °C to 700 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.5 °C |
| Brand | Vcam |
|---|---|
| Model | Mini Furnace Temperature Profiler |
| Measurement Principle | Thermocouple-based Contact Sensing |
| Temperature Range | -50 to 700 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.5 °C |
| Channel Count | 8 |
| Compliance | ISO Traceability Requirements |
| Environmental Operating Range | -50 to 700 °C |
| Brand | Vcam |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | XP Series Furnace Temperature Profiling System |
| Pricing | Available Upon Request |
| Temperature Measurement Principle | Thermocouple-Based |
| Measurement Method | Contact |
| Temperature Range | -50 °C to 700 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.5 °C |
| Display | LCD Digital |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | T1000S |
| Temperature Measurement Principle | Resistance-based (RTD/SPRT compatible) |
| Measurement Method | Contact |
| Temperature Range | −200 °C to +850 °C |
| Resolution | 0.001 °C |
| Accuracy | ±0.01 °C (full scale) |
| Long-term Stability | <5 mK/year |
| Channels | 10 simultaneous |
| Sampling Interval | 1 s per channel |
| Units | °C / °F / K / Ω |
| Built-in Standard | ITS-90 |
| Display | 7-inch capacitive touchscreen |
| Interface | USB |
| Probe Connector | 5-pin straight plug |
| Power Supply | 110/220 VAC, 50/60 Hz |
| Dimensions (L×W×H) | 365 × 260 × 160 mm |
| Operating Environment | 0–40 °C, ≤65% RH |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | T6000 |
| Temperature Measurement Principle | Resistance-based (RTD) |
| Measurement Method | Contact |
| Temperature Range | −200 to +1600 °C |
| Resolution | 0.001 °C |
| Accuracy | ±0.01 °C (for RTDs), ±0.3% FS (for thermistors), ±0.2% FS (for thermocouples) |
| Long-term Stability | <0.005 °C/year |
| Display | 7-inch capacitive touchscreen |
| Channel Configuration | Dual-channel, expandable |
| Sensor Compatibility | ITS-90-compliant platinum resistance thermometers (Pt100, Pt1000), NTC/PTC thermistors, and standard thermocouples (J, K, T, E, R, S, B, N) |
| Calibration Standard | Built-in ITS-90 reference implementation |