Thickness Gauge
Filter
Showing 31–60 of 78 results
| Brand | Defelsko |
|---|---|
| Origin | USA |
| Model | PosiTest F/G |
| Measurement Principle | Electromagnetic Induction (F-type) / Eddy Current (G-type) |
| F-Type Range | 0–2000 µm (0–80 mils) |
| G-Type Range | 0–200 µm (0–8 mils) |
| F-Type Accuracy | ±5 µm (≤100 µm), ±5% of reading (>100 µm) |
| G-Type Accuracy | ±1 µm (≤20 µm), ±5% of reading (>20 µm) |
| Probe Type | Permanent Magnet (F) / High-Frequency Eddy Current (G) |
| Compliance | ASTM D7091, ISO 2178, ISO 2360, SSPC-PA 2, GB/T 4956, GB/T 4957 |
| Power Source | None (magnet-driven) |
| Environmental Rating | IP65-equivalent robust housing |
| Calibration | NIST-traceable certificate supplied with each unit |
| Brand | DJH Designs |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DFM1 |
| Price Range | USD 70,000 – 140,000 |
| Brand | Elite |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Capillary-Focused |
| Price Range | USD 112,000 – 155,000 |
| Brand | Elite Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XU-100 (High-Cost-Performance XRF Coating Thickness Analyzer) |
| Price Range | USD 22,000 – 28,000 |
| Brand | EPK |
|---|---|
| Origin | Germany |
| Model | MiniTest 420 / 430 / 440 |
| Measurement Principle | Pulse-Echo & Echo-Echo (Coating-Compensated) |
| Thickness Range (Pulse-Echo) | 0.65–500 mm |
| Thickness Range (Echo-Echo) | 3–25 mm |
| Resolution | 0.01 mm (<99.99 mm), 0.1 mm (≥100 mm) |
| Sound Velocity Range | 1000–9999 m/s |
| Display | 128 × 64 backlit LCD |
| Dimensions | 130 × 73 × 24 mm (L×W×H) |
| Weight | ~190 g |
| Operating Temperature | –20 °C to +50 °C |
| Battery Life | ≥80 h continuous operation |
| Data Storage | Up to 5,000 readings across 10 user-defined groups |
| Interface | USB for data export and firmware update |
| Compliance | Designed for ISO 2400, ASTM E797, and EN 15317-compliant thickness verification workflows |
| Brand | KLA |
|---|---|
| Origin | USA |
| Manufacturer | Filmetrics (a KLA company) |
| Type | Benchtop Spectroscopic Reflectometry System |
| Model | F3-sX |
| Wavelength Options | 980 nm / 1310 nm / 1550 nm |
| Thickness Range | 15 nm – 3 mm (depending on configuration and film type) |
| Spot Size | 10 µm |
| Material Library | >130 preloaded optical constants |
| Software | FILMeasure 8 (local acquisition & analysis), FILMeasure Standalone (remote data processing) |
| Compliance | Designed for semiconductor fab, R&D, and QC environments supporting GLP/GMP traceability workflows |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | CMS2/STEP |
| Measurement Principle | Coulometric (Anodic Dissolution) per DIN EN ISO 2177 & ASTM B764-94 |
| Application Scope | Single/Multi-layer Metallic Coatings on Conductive or Non-conductive Substrates (e.g., Fe, Cu, ABS, PCB) |
| Thickness Range | 0.05–50 µm |
| Electrolytic Rate Selection | 0.1–10 µm/min |
| Measured Area | 0.6–3.2 mm² (via interchangeable O-rings) |
| STEP Function | Simultaneous Thickness & Potential Difference Measurement (Ni multilayer systems) |
| Display | High-resolution color LCD |
| Software Features | Graphical voltage curve display, statistical analysis, multi-language UI, configurable units |
| Compliance | DIN EN ISO 2177, ASTM B764-94, DIN 50022 |
| Accessories | V18 semi-automated stand with spherical support & rotating sample plate, 3-position electrolyte bottle holder (100 mL each) |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Models | PMP10, RMP30-S, MPO, FMP |
| Pricing | Available Upon Request |
| Brand | Jinhuatester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CHY-01 |
| Measurement Range | 0–5 mm (custom fixtures available) |
| Measurement Pressure | 17.5 ± 1 kPa (for films), 100 ± 1 kPa (for paper, optional fixture required) |
| Accuracy | ±0.5 µm |
| Resolution | 0.1 µm |
| Contact Area | 50 mm² (film mode), 200 mm² (paper mode) |
| Traverse Speed | 10 mm/min (adjustable) |
| Dimensions (W×D×H) | 454 × 352 × 500 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 30 kg |
| Interface | RS232 serial port |
| Standard Accessories | Main unit, calibration gauge blocks, thermal micro-printer |
| Optional Accessories | PC-based measurement software, RS232 communication cable, calibrated weight kits, automated multi-point sample feeder |
| Brand | Jinhuatester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CHY-01 |
| Measurement Range | 0–5 mm (customizable fixtures available) |
| Measuring Pressure | 17.5 ± 1 kPa (for films), 100 ± 1 kPa (for paper) |
| Accuracy | ±0.5 µm |
| Resolution | 0.1 µm |
| Contact Area | 50 mm² (film mode), 200 mm² (paper mode) |
| Traverse Speed | 10 mm/min (adjustable) |
| Dimensions | 454 × 352 × 500 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 30 kg |
| Interface | RS232 |
| Compliance | ASTM D6988, ISO 4593, ISO 534, GB/T 6672, GB/T 451.3 |
| Brand | Jinhuatester |
|---|---|
| Model | DBH-01 |
| Measurement Principle | Capacitive Grid (Capacitance-Based Contact Sensing) |
| Measuring Range | 0–12.7 mm |
| Resolution | 0.001 mm |
| Accuracy | ±0.003 mm |
| Repeatability | ≤4 µm |
| Sample Diameter Range | φ20–φ300 mm |
| Max. Sample Height | 350 mm |
| Display | 7-inch TFT True Color Touchscreen |
| Data Storage | Up to 100 test groups (10 values/group) |
| Power Supply | 220 VAC, 50 Hz |
| Dimensions (W×D×H) | 450 × 430 × 635 mm |
| Weight | 20 kg |
| Operating Environment | 15–35 °C, 40–60 % RH |
| Compliance | YBB00332002–2015, YBB00332003–2015, YBB00032004–2015, GB 12415–90, GB 2641–1990, GB 2639–1990 |
| Brand | KB |
|---|---|
| Model | KYH-1000 |
| Type | Coulometric Electrolytic Thickness Gauge |
| Measurement Principle | Controlled-potential anodic dissolution (ASTM B504, ISO 2177) |
| Measurable Layers | Cu₂O and CuO on copper substrates |
| Thickness Range | 0.00001–6 µm |
| Resolution | 0.00001 µm |
| Voltage Output | 0–5 V DC, digitally adjustable |
| Current Output | 0–100 mA DC |
| Voltage Resolution | 1 mV |
| Current Resolution | 0.1 mA |
| Sample Diameter Range | 1–25 mm |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 440 × 410 × 135 mm |
| Compliance | NB/T 10194–2019 (Chinese National Standard for Electrolytic Measurement of Copper Oxide Films) |
| Software | KB-ThickControl v3.x with audit trail, data export (CSV, PDF), statistical analysis (mean, SD, CPK), and GLP-compliant user access control |
| Brand | KLA |
|---|---|
| Origin | USA |
| Manufacturer | KLA Corporation |
| Product Type | Imported Instrument |
| Model | F54 Series |
| Pricing | Upon Request |
| Thickness Range | 4 nm – 100 µm (depending on configuration) |
| Wavelength Range | 190–1700 nm (F54-UVX) |
| Spot Size | Down to 1 µm (with 50× objective) |
| Aperture Options | 500, 250, 100, and 50 µm |
| Measurement Speed | Up to 2 points per second |
| Maximum Sample Diameter | 450 mm |
| Built-in Material Library | >130 refractive index & extinction coefficient datasets |
| Compliance | ASTM F398, ISO/IEC 17025-compatible operation environment |
| Software | Filmetrics F54 Metrology Suite v6.x (Windows 10/11, USB 3.0 interface) |
| Brand | KLA |
|---|---|
| Origin | USA |
| Manufacturer | KLA Corporation |
| Product Type | Imported Instrument |
| Model | F54-XY Series |
| Pricing | Upon Request |
| Thickness Range (F54-XY) | 20 nm – 50 µm |
| Wavelength Range (F54-XY) | 380–1050 nm |
| Thickness Range (F54-XY-UV) | 4 nm – 35 µm |
| Wavelength Range (F54-XY-UV) | 190–1100 nm |
| Thickness Range (F54-XY-NIR) | 100 nm – 120 µm |
| Wavelength Range (F54-XY-NIR) | 950–1700 nm |
| Thickness Range (F54-XY-EXR) | 20 nm – 120 µm |
| Wavelength Range (F54-XY-EXR) | 380–1700 nm |
| Thickness Range (F54-XY-UVX) | 4 nm – 120 µm |
| Wavelength Range (F54-XY-UVX) | 190–1700 nm |
| Maximum Sample Size (F54-XY-200) | 200 mm |
| Maximum Sample Size (F54-XYT-300) | 300 mm |
| Measurement Speed | Up to 2 fields of view per second |
| Stage Type | Motorized XY stage (F54-XY-200) |
| Pattern Recognition | Yes, supports both arrayed and non-arrayed wafers |
| Software | FILMapper v6.x or later |
| Compliance | NIST-traceable calibration standards included |
| Material Library | >130 built-in optical constants |
| Brand | KLA |
|---|---|
| Origin | USA |
| Model | Profilm 3D |
| Measurement Principle | Vertical Scanning Interferometry (VSI) & Phase-Shifting Interferometry (PSI) |
| Thickness Range (VSI) | 50 nm – 100 mm |
| Thickness Range (PSI) | 0 – 3 µm |
| Reflectance Range | 0.05% – 100% |
| Piezo Scan Range | 500 µm |
| XY Stage Options | 100 mm × 100 mm or 200 mm × 200 mm |
| Compliance | ISO 25178-604, ISO 9000, ASME B46.1 |
| Roughness Parameters | 47 standardized (ASME Y14.36M, ISO 4287, ISO 25178-2) |
| Software | ProfilmOnline cloud-based analysis platform |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink Co., Ltd. |
| Model | CHY-C2A |
| Load Range | 0–2 mm (standard), 0–6 mm / 0–12 mm (optional) |
| Resolution | 0.1 µm |
| Measurement Speed | 10 tests/min (adjustable) |
| Measuring Pressure | 17.5 ± 1 kPa (for films), 50 ± 1 kPa (for paper) |
| Contact Area | 50 mm² (films), 200 mm² (paper) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions | 461 × 334 × 357 mm (L×W×H) |
| Net Weight | 32 kg |
| Compliance | ISO 4593, ISO 534, ISO 3034, GB/T 6672, GB/T 451.3, GB/T 6547, ASTM D374, ASTM D1777, TAPPI T411, JIS K6250, JIS K6783, JIS Z1702, BS 3983, BS 4817 |
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 1120218 |
| Display | 5-digit LCD |
| Resolution | 0.001 mm |
| Accuracy | ±0.002 mm |
| Measurement Range | 0–12.5 mm or 0–25 mm (selectable) |
| Zeroing | Manual mechanical zero adjustment |
| Output Interface | RS-232 serial port (printer-compatible) |
| Power Supply | 3 V lithium battery |
| Battery Life | Up to 4000 hours of continuous operation |
| Standard Accessories | Bench-mounted base, precision anvil, calibrated contact probe |
| Optional Accessories | Weighted loading kit (for standardized compressive force), V-groove depth probe |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | 27MG |
| Weight | 340 g |
| Dimensions (W × H × D) | 84.0 × 152.4 × 39.6 mm |
| IP Rating | IP65 |
| Operating Temperature | –10 °C to 50 °C |
| Battery Life | Up to 150 h (no backlight) / 30 h (with backlight) |
| Thickness Range | 0.080–635 mm |
| Material Sound Velocity Range | 0.508–18.699 mm/µs |
| Resolution Options | 0.1 mm (low) / 0.01 mm (standard) |
| Probe Frequency Range | 2.25–10 MHz |
| Receiver Bandwidth | 1–18 MHz |
| Display | Backlit LCD with color-coded keypad |
| Compliance | EN 15317, MIL-STD-810F Method 511.4, NFPA 70 Class I, Div 2, Group D |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | 38DL PLUS |
| IP Rating | IP67 |
| Compliance | EN 15317 |
| Weight | 0.814 kg |
| Operating Temperature | –10 °C to 50 °C |
| Display | Color transflective VGA (56.16 mm × 74.88 mm) |
| Thickness Range | 0.080 mm to 635.00 mm (material- and probe-dependent) |
| Resolution Options | 0.1 mm (low), 0.01 mm (standard), 0.001 mm (high-res option) |
| Sound Velocity Range | 0.508 mm/µs to 13.998 mm/µs |
| Dual-element Probe Frequency Range | 2.0 MHz to 30 MHz (–3 dB) |
| High-Penetration Option | 0.50 MHz to 30 MHz (–3 dB) |
| Data Storage | 475,000 thickness readings or 20,000 waveforms (internal) |
| Interface | USB 1.0, RS-232, VGA video output |
| Battery Life | Up to 14.7 h (Li-ion) |
| Fast charge | 2–3 h |
| Environmental Certification | MIL-STD-810F (shock, vibration, explosive atmosphere per NFPA 70, Class I, Div. 2, Group D) |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | 39DL PLUS |
| Update Rate | up to 60 Hz |
| Connectivity | Integrated Wireless (Wi-Fi/Bluetooth) |
| Application Type | Precision & Corrosion Thickness Measurement |
| Compliance | Designed for ASTM E797, ISO 16809, and NACE SP0106-compliant inspection workflows |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | 45MG |
| Operating temperature | –10 °C to 50 °C |
| Thickness range | 0.080 mm to 635 mm (material-, probe-, and configuration-dependent) |
| Resolution options | 0.1 mm / 0.01 mm / 0.001 mm |
| Sound velocity range | 0.508–18.699 mm/µs |
| Single-element mode | 2.25–30 MHz (standard), 0.5–30 MHz (High Penetration option) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 45MG |
| Pricing | Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | 72 DLPLUS |
| Type | Portable Ultrasonic Thickness Gauge |
| Measurement Principle | Pulse-Echo Ultrasonic Time-of-Flight (TOF) |
| Minimum Measurable Thickness | ≤0.1 mm (steel equivalent) |
| Display | High-contrast monochrome LCD with backlight |
| Operating Temperature | –10 to 50 °C |
| IP Rating | IP67 |
| Power Supply | Two AA alkaline or lithium batteries (up to 200 hours battery life) |
| Data Storage | Internal memory for up to 500 readings |
| Output Interface | RS-232 serial port (optional USB adapter available) |
| Compliance | Conforms to ASTM E797, ISO 2400, and EN 15317 standards |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | Magna-Mike 8600 |
| Measurement Principle | Magnetic Induction (Hall Effect) |
| Max Thickness Range | 25.4 mm |
| Display | Full-color VGA (640 × 480) LCD |
| Data Output | USB 2.0, RS-232, VGA |
| Environmental Rating | IP67 |
| Drop/Shock/Vibration Compliance | MIL-STD-810G |
| Battery Life | Up to 16 h (Li-ion) |
| Operating Temperature | –10 °C to 50 °C |
| Resolution | 0.0001 in (0.001 mm) |
| Probe Options | Straight (86PR-1), Right-Angle (86PR-2) |
| Wear Cap Types | Standard, Chisel, Enhanced |
| Target Options | 6 steel balls (1.58–6.35 mm), 2 discs, 1 steel wire (1.14 mm Ø) |
| Data Logger | File-based alphanumeric recorder with .txt/.csv export to MicroSD |
| Software Interface | WINXL for Excel/SPC integration |
| Calibration Modes | Single-point, multi-point, stored calibration recall |
| Reporting | Onboard report generation, statistical strip chart view |
| Brand | OptiSense |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Industrial |
| Pricing | Upon Request |
| Brand | OptiSense |
|---|---|
| Origin | Germany |
| Model | Infrared Type |
| Measurement Principle | Photothermal (Light-Heat) Method |
| Compliance | DIN EN 15042-2 |
| Thickness Range | 1–300 µm |
| Spot Size | Ø 1 mm |
| Measurement Distance | ≈35 mm |
| Repeatability | ≤1 Hz |
| Measurement Time | 32–2048 ms |
| Accuracy | ±3% of reading |
| Resolution | ~1% of reading |
| Angular Tolerance | ±15° |
| Probe Dimensions | L 160 × W 50 mm |
| Probe Weight | 200 g |
| Terminal Dimensions | 80 × 180 × 42.5 mm |
| Total Device Weight | 750 g |
| Power Supply | 4 rechargeable Li-ion batteries |
| Battery Life | Up to 10 hours continuous operation |
| Interface | USB |
| Brand | OptiSense |
|---|---|
| Origin | Germany |
| Model | Automatic |
| Measurement Principle | Photothermal (Laser-Based Non-Contact) |
| Standards Compliance | DIN EN 15042-2 |
| Max. Measuring Range | 0–300 µm (on metallic substrates), 0–60 µm (on non-metallic substrates) |
| Spot Size | Ø 0.5 mm |
| Measurement Distance | 16 mm ±1 mm |
| Angular Tolerance | ±15° |
| Laser Class | 1M (≤0.5 W peak pulse power) |
| Repetition Rate | up to 1 Hz |
| Measurement Duration | 8–512 ms |
| Resolution | ~3% of actual thickness |
| Accuracy | ~5% of actual thickness |
| Probe Weight | ~100 g |
| Terminal Dimensions | 227 × 267 × 100 mm |
| Terminal Weight | 2.2 kg |
| Power Supply | 230 V AC, 50 Hz, max. 40 W |
| Interface | 10 Mbps Ethernet (RJ45) |
| Brand | OptiSense |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpecEL |
| Pricing | Upon Request |
| Brand | Oxford Instruments |
|---|---|
| Origin | USA |
| Model | CMI233 |
| Measurement Principle | Dual-mode (Magnetic Induction for ferrous substrates |
| Measurement Range | 0–3.05 mm (magnetic induction), 0–1.52 mm (eddy current) |
| Resolution | 0.1 µm |
| Accuracy | ±1% or ±0.1 µm (per certified reference standards) |
| Minimum Substrate Thickness | 0.35 mm |
| Minimum Curvature Radius | 5 mm (convex), 25 mm (concave) |
| Minimum Test Area | Ø20 mm |
| Compliance | ASTM B499, B530, B244, B259 |
| Data Storage | 12,400 readings |
| Display | 1/2-inch backlit LCD |
| Interface | RS-232 serial port |
| Power | 9 V alkaline or rechargeable battery |
| Weight | 260 g (incl. battery) |
| Dimensions | 149 × 79.4 × 30.2 mm |
| Units | Switchable metric/imperial |
| Statistical Functions | Mean, SD, min/max, histogram, CPK, count |
| Scan Mode | Time-based averaging with min/max capture |
| Keypad | Sealed membrane (9-key basic / 16-key enhanced) |
| Brand | QiaoBang Instrument |
|---|---|
| Origin | Jiangsu, China |
| Model | XAD |
| Price Range | USD 125,000 – 210,000 |
| Measurement Principle | Total External Reflection X-Ray Fluorescence (TXRF) with Multi-Channel Capillary Optics |
| Minimum Spot Size | 10 µm |
| Excitation Intensity Gain | 10²–10³× vs. conventional collimators |
| Compliance | ASTM F1689, ISO 3497, IPC-4552A, USP <232>/<233>, GLP/GMP-ready data audit trail |