Thin Layer Chromatography Instrument
Filter
Showing 1–30 of 58 results
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | Plate Express TLC |
| Operation Mode | Automated |
| Desolvation | Nitrogen Purge |
| Sample Platform | Adjustable for Standard TLC Plates (e.g., 20 × 20 cm, 10 × 20 cm, 5 × 10 cm) |
| Compatibility | Designed for Integration with Expression® CMS Compact Mass Spectrometer |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | AS30 |
| Instrument Type | Thin-Layer Chromatography (TLC) Sample Spotter |
| Spotting Method | Non-contact spray spotting with programmable overlap capability |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | <0.2 nm |
| Stage Dimensions | 500 × 380 × 180 mm |
| Spotting Speed | 3–120 s/µL (solvent-dependent) |
| Minimum Spotting Volume | 0.1 µL |
| Volume Range Options | 0.1–10 µL and 0.1–100 µL |
| Spotting Precision | ±0.5 nL |
| Programmable Methods | Up to 10 stored protocols |
| Sample Capacity (optional autosampler) | 144 vials |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | CD60 |
| Instrument Type | HPTLC Densitometer |
| Operation Mode | Fully Automated |
| Detection Modes | Absorption, Reflection, Fluorescence, Transmission |
| Wavelength Range | 190–900 nm |
| Light Sources | Deuterium Lamp, Tungsten-Halogen Lamp, Mercury Lamp |
| Monochromator | Stepper Motor-Driven Holographic Grating (1200 lines/mm) |
| Spectral Bandwidth | 5–260 nm |
| Wavelength Accuracy | < ±0.1 nm |
| Wavelength Repeatability | < ±0.2 nm |
| Minimum Spatial Resolution | 0.025 mm |
| Imaging Wavelength Range | 190–900 nm |
| Sample Stage Dimensions | 265 × 200 mm |
| Scan Speed | 20 mm/s |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | SG1 / DS20 |
| Spray Method | Programmable, Quantitative, Region-Specific Aerosol Deposition |
| Droplet Size | 1–10 µm |
| Spray Platform Area | 20 × 20 mm |
| Scan Speed | 50–200 mm/s |
| Wavelength Range | 2–4 mm (Note: This value is physically inconsistent with optical spectroscopy |
| likely refers to spray nozzle orifice diameter — corrected to “Nozzle Orifice | 2–4 mm”) |
| Light Sources | Deuterium lamp, Tungsten-halogen lamp, Mercury lamp |
| Wavelength Reproducibility | < 0.2 nm (applicable to integrated UV/Vis detection module, not spray function) |
| Compliance | GxP-ready software architecture with audit trail capability |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | DD80 |
| Instrument Type | Automated TLC Imaging & Densitometry System |
| Operation Mode | Fully Automatic |
| Detection Mode | Low-Fluorescence Substance Imaging |
| Wavelength Options | 254 nm and 366 nm UV |
| Light Sources | White LED, UV Fluorescent Lamps, UV LEDs |
| Imaging Sensor | 24-Megapixel Full-HD Digital Camera |
| Spectral Bandwidth Management | Auto Background Correction & Real-Time Image Optimization |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spatial Resolution | 7560-pixel RGB + IR Photometric Detection System |
| Focusing Mechanism | 19-Point Cross-Hair Autofocus Array |
| Stage Dimensions | 400 × 500 × 440 mm (W × D × H) |
| Frame Rate | 50 fps Continuous Capture |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | ADC 3 |
| Instrument Type | Automatic Thin-Layer Chromatography (TLC) Development System |
| Operation Mode | Fully Automated |
| Sample Format | HPTLC plates up to 20 × 10 cm |
| Chamber Configuration | Dual-saturation chambers with integrated RH control |
| Compliance | cGMP/GLP, FDA 21 CFR Part 11 compliant |
| Software Control | visionCATS v3.x or later |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | AMD 2 |
| Instrument Type | Thin-Layer Chromatography (TLC) Multiple Development System |
| Compliance | GLP/GMP-Compliant |
| Control | Programmable, CCD-Monitored |
| Solvent Capacity | Up to 5 solvents |
| Development Stages | Multi-step, Gradient Elution Capable |
| Max. Separation Density | ~40 components within 80 mm |
| Automation Level | Fully Automated Pre-saturation, Development, Drying |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | ATS 4 |
| Instrument Type | Automatic Thin-Layer Chromatography Sampler |
| Sampling Modes | Contact (spot) and Non-contact Pneumatic Spray (band/square) |
| Sample Volume Range | 100 nL – 1 mL |
| Precision | ±1 nL / ±2 nL / ±10 nL (for 10 µL / 25 µL / 100 µL syringes) |
| Plate Capacity | Up to 20 × 20 cm, thickness up to 4 mm |
| X-axis Resolution | 0.1 mm/step (80 steps/mm), travel 5–195 mm |
| Y-axis Resolution | 0.1 mm/step (40 steps/mm), travel 5.0–195.0 mm |
| Sample Carrier | 66 × 2 mL vials (12 × 32 mm) or optional 96-well microtiter plate |
| Operating Pressure | 4–6 bar (65–87 psi), compressed air or nitrogen |
| Gas Flow Rate | 0.2–0.3 L/min (spot mode) |
| Integrated Heating Function | Yes |
| Syringe Options | 10 µL, 25 µL, 100 µL |
| Onboard Microprocessor Control | Yes |
| Software Interface | winCATS v1.4.12 or higher |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | BioLuminizer® 2 |
| Instrument Type | TLC Imaging System |
| Detector Technology | Cooled CCD with 65% Quantum Efficiency |
| Data Depth | 16-bit |
| Pixel Resolution | High Spatial Resolution (Optimized for TLC Plate Detail Capture) |
| Application Focus | Bioluminescent Bioautography Coupled with Planar Chromatography |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | Derivatizer |
| Operation Mode | Automatic |
| Instrument Type | Preparative Thin-Layer Chromatography System |
| Compliance | Designed for GLP-compliant laboratories |
| Solvent Compatibility | All conventional organic and aqueous solvents |
| Reagent Consumption | ~3 mL for 20 × 10 cm plates, ~4 mL for 20 × 20 cm plates |
| Enclosure | Sealed, fume-controlled chamber |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | HPTLC PRO |
| Instrument Type | Preparative TLC System |
| Operation Mode | Fully Automatic |
| Sample Capacity | Up to 75 samples per run |
| Plate Capacity | Up to 5 TLC plates simultaneously |
| Solvent Systems | Up to 3 different developing solvents in one sequence |
| Software Compliance | FDA 21 CFR Part 11 compliant |
| Module Dimensions | 384 × 550 × 510 mm (W × D × H) |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | Linomat 5 |
| Instrument Type | Thin-Layer Chromatography (TLC) Sample Spotter |
| Regulatory Compliance | IQ/OQ Qualified |
| Software Integration | visionCATS v3.x or later |
| Application Environment | GLP/GMP-Compliant Laboratories |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Kit Type | Standard TLC Basic Toolset |
| Application | Preparative and Analytical TLC |
| Compliance | Designed to Support ASTM D7925, ISO 17025–Compliant Workflows |
| Software Integration | Compatible with CAMAG VisionCats (Optional) |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | TLC Scanner 4 |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence |
| Wavelength Range | 190–900 nm |
| Light Sources | Deuterium Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp (automatically switchable) |
| Wavelength Reproducibility | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Sample Stage Dimensions | 200 × 200 mm |
| Scanning Speed | 1–100 mm/s |
| Regulatory Compliance | Fully compliant with FDA 21 CFR Part 11 for electronic records and signatures |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | TLC Visualizer 3 |
| Light Sources | 254 nm short-wave UV (epi-illumination), 366 nm long-wave UV (epi-illumination), white light (epi-illumination and trans-illumination) |
| Camera Sensor | High-resolution industrial CMOS |
| Software Platform | visionCATS v3.x or later |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | TLC-MS Interface 2 |
| Instrument Type | TLC–MS Coupling Interface |
| Compatibility | Universal LC-MS Systems (ESI, APCI, MALDI sources) |
| Operation Mode | Online and Offline Elution |
| Solvent Consumption | Low (≤ 200 µL per band) |
| Positioning Accuracy | ≤ ±50 µm |
| Washout Function | Integrated reverse-flow purge to prevent channel clogging |
| Sample Recovery | Direct collection into vials (1.5 mL or 2 mL) for downstream analysis (NMR, FTIR, ESI-MS, MALDI-MS) |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | ZY-600U |
| Instrument Type | TLC Imaging System |
| Operation Mode | Fully Automatic |
| Measurement Mode | Transmitted Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | UV Lamps (254 nm & 365 nm), White Light Lamp (400–750 nm) |
| Detector | High-Sensitivity CCD Camera |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.01 cm⁻¹ |
| Spatial Resolution | 0.01 cm |
| Imaging Wavelengths | UV254/UV365 (transmission), Visible (400–750 nm) |
| Sample Stage Dimensions | 200 mm × 200 mm |
| Scanning Speed | 100 mm/s |
| Image Sensor | 1280 × 1024 pixels, high-frame-rate acquisition |
| UV Transmission Efficiency | ≥92% |
| OS Compatibility | Windows 2000/XP |
| Interface | USB 2.0 |
| Rf Calculation Accuracy | ≤0.01 cm repeatability |
| Inter-unit Measurement Variation | ≤0.5% |
| Data Export Formats | JPG, BMP, TIFF, PNG |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GoodLook-1000 |
| Instrument Type | TLC Imaging System |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon lamp, Tungsten-halogen lamp, High-pressure Mercury lamp |
| Monochromator | Holographic grating (1200 lines/mm) with nitrogen purge capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White light (400–700 nm) |
| Sample Stage Capacity | Accommodates 200 mm × 200 mm TLC plates |
| Maximum Scanning Speed | 100 mm/s |
| Camera Resolution | 12 MP |
| Exposure Time Range | 0–10 s |
| Gain Adjustment | 0–100% |
| Imaging Modalities | Visible, UV, Fluorescence, Chemiluminescence |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GoodLook-2000 |
| Instrument Type | TLC Imaging System |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon lamp, Tungsten-halogen lamp, High-pressure Mercury lamp |
| Monochromator | Holographic grating (1200 lines/mm) with nitrogen purge capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White light (400–700 nm) |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC plates |
| Scanning Speed | Max 100 mm/s |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GoodSee-20E |
| Instrument Type | TLC Imaging System |
| Imaging Wavelengths | 254 nm UV, 365 nm UV, Visible Light |
| Maximum Imaging Area | 200 × 200 mm |
| Camera Resolution | ≥12 MP |
| Power Supply | 220 V, 50 Hz, 90 W |
| Light Source Power | 30 W per channel |
| Scanning Speed | Up to 100 mm/s |
| Interface | USB |
| Software Platform | Windows 7 / 10 |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | TLC Imaging System |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm) with Optional Nitrogen Purge |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC Plates |
| Maximum Scanning Speed | 100 mm/s |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | KH-3500Plus II |
| Instrument Type | TLC Densitometer & Imaging System |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence, Chemiluminescence |
| Wavelength Range | 190–1000 nm |
| Light Sources | Tungsten-Halogen Lamp, Deuterium Lamp, Mercury Lamp (Auto-Switching) |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Option |
| Spectral Bandwidth | 5 nm / 10 nm / 20 nm (Selectable |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | <0.1 nm |
| Minimum Spatial Resolution | 10–25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light (Fully Automated Control) |
| Sample Stage Capacity | 200 mm × 200 mm TLC Plate (Customizable to 300 mm × 200 mm) |
| Scan Speed | 0–120 mm/s |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | TLC Scanner |
| Operation Mode | Fully Automatic |
| Measurement Modes | Reflectance, Fluorescence (optional), Absorbance |
| Wavelength Range | 190–700 nm (auto-configurable) |
| Light Source | Deuterium Lamp + Tungsten-Halogen Lamp |
| Monochromator | Holographic Grating |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ≤ ±1 nm |
| Wavelength Repeatability | RSD ≤ 2.0% |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelength Range | 190–700 nm |
| Sample Stage Capacity | Accommodates 200 mm × 200 mm TLC plates |
| Maximum Scan Speed | 100 mm/s |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KH-2300 |
| Instrument Type | TLC Scanner |
| Operation Mode | Fully Automatic |
| Measurement Modes | Reflectance, Fluorescence (optional), Absorbance |
| Wavelength Range | 190–700 nm (automatically programmable) |
| Light Source | Deuterium Lamp + Tungsten Halogen Lamp |
| Monochromator | Holographic Grating |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ≤ ±1 nm |
| Wavelength Repeatability | RSD ≤ 2.0% |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Up to 20 × 30 cm TLC plates of arbitrary thickness |
| Scanning Speed | 0–50 mm/s |
| Auto-sampler Capacity | 96 × 2 mL vials |
| Minimum Spot Volume | 10 nL |
| Spotting Modes | Circular, Band, Square |
| Band Length Range | 5–195 mm |
| Heating Base Temperature Range | 30–60 °C (±1 °C) |
| Optional Accessories | TS-II Dual-Nozzle Electrospray Nebulizer, TD-II Automated TLC Plate Coater, TK-10 Electronic Development Chamber |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KH-3000 |
| Instrument Category | TLC Scanner |
| Wavelength Range | 190–900 nm (continuously adjustable) |
| Light Sources | Deuterium lamp & tungsten-halogen lamp (auto-switching) |
| Monochromator | Holographic grating (1200 lines/mm) |
| Spectral Bandwidth | 10 nm |
| Wavelength Accuracy | ±0.5 nm |
| Minimum Resolution | 25–50 µm |
| Sample Stage | Accommodates 200 mm × 200 mm TLC plates |
| Scan Speed | 0–120 mm/s |
| Detection Modes | Absorbance & optional Fluorescence |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | TLC Densitometer |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence, Chemiluminescence |
| Wavelength Range | 190–900 nm (continuously adjustable) |
| Light Sources | Tungsten-halogen lamp, Deuterium lamp, Mercury lamp (auto-switching) |
| Monochromator | Holographic grating (1200 lines/mm) with nitrogen purge capability |
| Spectral Bandwidth | 5 nm / 10 nm / 20 nm (user-selectable |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | <0.1 nm |
| Minimum Spatial Resolution | 10–25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light (fully automated control) |
| Sample Stage Capacity | Accommodates 200 mm × 200 mm TLC plates (customizable up to 300 mm × 200 mm) |
| Scan Speed | 0–120 mm/s |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | TLC Scanner |
| Measurement Mode | Absorption (Fluorescence optional) |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon lamp, Tungsten-halogen lamp, High-pressure Mercury lamp |
| Monochromator | Holographic grating (1200 lines/mm) with nitrogen purge capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < ±1 nm |
| Wavelength Repeatability | < ±0.2 nm |
| Minimum Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White light |
| Sample Stage Capacity | 200 mm × 200 mm TLC plate |
| Maximum Scan Speed | 100 mm/s |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | TLC Scanner |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence, Chemiluminescence |
| Wavelength Range | 190 nm – 1000 nm |
| Light Sources | Tungsten-Halogen Lamp, Deuterium Lamp, Mercury Lamp (Auto-Switching) |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Function |
| Spectral Bandwidth | 5 nm / 10 nm / 20 nm (Selectable) |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Reproducibility | < 0.1 nm |
| Minimum Spatial Resolution | 10–25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light (Fully Automated Control) |
| Sample Stage | Accommodates 200 mm × 200 mm TLC plates (customizable to 300 mm × 200 mm) |
| Scan Speed | 0–120 mm/s |
| A/D Converter | 24-bit, 8-channel, 20 µs dual conversion |
| Slit Dimensions | Length 0–8 mm, Width 0–4 mm (Continuously Variable, PC-Controlled) |
| Fluorescence Filters | Standard set of six (K320, K360, K400, K450, K510, K550) |
| Detector | Photomultiplier Tube (PMT) |
| Data Acquisition Rate | 30,000 data points per second |
| Communication Interface | USB 2.0 |
| Compliance | Fully supports 21 CFR Part 11, electronic signatures, and IQ/OQ/PQ validation protocols |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Preparative Thin-Layer Chromatograph |
| Model | KH-CTLC-II |
| Wavelengths | 254 nm and 365 nm (UV) |
| Light Source | Dual-band UV Lamp |
| Sample Platform | Rotating Circular TLC Plate (Ø245 mm) |
| Flow Rate Range | 0–15 mL/min |
| Flow Accuracy | ±1% |
| Separation Capacity | 100 mg–2 g per run |
| Rotational Speed | 100–1450 rpm |
| Plate Thickness Options | 1, 2, 3, 4, 6, 8 mm |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SP-20E |
| Instrument Type | Automated TLC Sample Spotter |
| Detection Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC Plates |
| Maximum Scanning Speed | 100 mm/s |
| Spotting Mode | Contactless Linear Band Deposition |
| Spotting Length | 5–195 mm (customizable) |
| Spotting Volume | 1–20 µL (customizable up to higher volumes) |
| Flow Rate Options | 0.5, 1, 2, 5, 10 µL/min |
| Power Supply | 220 V, 50 Hz, 90 W |
| Software Platform | Windows 7/10 Compatible Dedicated TLC Spotting Workstation |