Empowering Scientific Discovery

Tianjin Duoweilai Bo Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelDS-CS204AE-FMX-19-NGA
Cooling PrincipleClosed-Cycle Gifford-McMahon Refrigeration
Base Temperature<9 K
Temperature Range<9 K to 350 K
Vacuum CompatibilityUHV (≤1×10⁻⁹ Torr)
Structural MaterialWelded Stainless Steel with OFHC Copper Radiation Shield
Interface1.33" Mini-Conflat or VCR 1/4"
Cold HeadDE-204AE
CompressorARS-4HW
Helium Purity Requirement99.999%
Temperature Stability±0.1 K
Cooling Water Flow2.3 L/min @ 10–35 °C
Noise Level60 dBA
Dimensions (L×W×H)483×434×516 mm
Weight72 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelX-4
Cooling Capacity Options4 K, 5.5 K, 10 K
Base Cooling SystemDE-202 or DE-204 GM Cryocooler
CompressorARS-2HW
Vacuum ShroudStainless Steel with 4 Standard Optical Ports (5th Port Optional at Base)
Optical WindowsTwo High-Purity Fused Silica, 1.5-inch Diameter
Sample Viewing GeometryF/1.1 Aperture Ratio
Temperature Control SensorsCalibrated Silicon Diode (±12 mK accuracy, 4-ft lead), Control-grade Silicon Diode (±0.5 K)
Electrical Feedthrough10-pin Hermetic Connector
Heating36 Ω Thin-Film Heater
Radiation ShieldNickel-Plated Oxygen-Free Copper
Helium Transfer LinesTwo Flexible Cryogenic Lines
Operating Temperature Range (with Upgrade)6 K to 700 K Continuous Sweep
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelX-1AL-4
TypeVertical
Cooling MethodHelium-Free Closed-Cycle Refrigeration
Base Temperature≤ 4 K (typical)
Optical AccessDual Side Ports + Top Window
Vibration IsolationEngineered for Ultra-Low-Vibration Operation
Mounting ConfigurationOptical Table Compatible
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelPSG-SM
Product CategoryCryogenic Temperature-Controlled Probe Station
Operation ModeSemi-Automatic
Cooling MethodDual-Cryocooler Closed-Cycle Refrigeration (DE210/DE215)
Base Temperature<4 K
Temperature Range5 K–350 K (optional high-temp stage up to 800 K)
Magnetic Field±3 T vertical (optional ±6 T or vector magnet)
Vacuum Chamber11″ stainless steel
Sample Stage Diameter1.75″ (supports 2″ wafers)
Vibration Level<1 µm RMS
MicroscopyStandard 7:1 zoom lens (3 µm resolution), optional 16:1 (2 µm resolution)
Probe Arm ConfigurationsDC/LF, RF (up to 67 GHz), optical fiber (UV–Vis–IR)
Temperature Stability<50 mK
Pump-Down Time~120 min
Cool-Down Time to 10 K~5 h (DE210S)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelDE-210
Cooling Capacity1 W at 4.2 K (with optional 4K cold head) / 4 W at 10 K (with optional 10K cold head)
Vibration Level< 5 µm peak-to-peak (typical, at cold head flange)
Operating Noise< 65 dB(A) at 1 m
Helium CircuitClosed-cycle, helium-recirculating
CompressorARS-10HW, air-cooled, oil-lubricated
Cold HeadDE-210AF, Gifford-McMahon type
Flexible Transfer LinesTwo 3-m helium gas lines (stainless steel braided, vacuum-jacketed)
Minimum Base Temperature≤ 4.2 K (with 4K cold head)
Typical Cool-down Time< 3.5 hours to 4.2 K from 300 K
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelX-3
Cooling Capacity Options4 K (0.1 W @ 4.2 K), 5.5 K (1 W @ 10 K), or 10 K
Cold Head CompatibilityDE-202, DE-204, DE-210 series
Construction MaterialAluminum (standard), Stainless Steel (customizable)
Vacuum EnclosureAluminum or stainless steel DMX-3 vacuum shroud optimized for electrical transport measurements
Radiation ShieldAluminum thermal radiation shield
Temperature Sensing±0.5 K calibrated silicon diode (control), ±12 mK calibrated silicon diode with 4-ft lead (sample-stage metrology)
Electrical Interface10-pin hermetic feedthrough, four dedicated low-noise measurement leads, electrically isolated sample stage
Optional Upgrades450 K / 800 K high-temperature insert, custom thermometer mounting, custom wiring harness, custom sample holder geometry
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelX-12-1
TypeVertical
Cooling SourceHelium-Free Closed-Cycle Refrigeration
Base Temperature Options4 K, 5.5 K, or 10 K (dependent on cold head selection: DE-202 or DE-204)
Minimum Tail Diameter19 mm (standard: 25 mm)
Vacuum Jacket MaterialNon-magnetic Aluminum
Radiation ShieldPolished Oxygen-Free Copper (replaces Ni-plated Cu)
Application-Specific DesignOptimized for in-situ magnetic field integration (e.g., electromagnets, superconducting magnets)
Compliance ContextDesigned for GLP-compliant low-temperature characterization under static or swept magnetic fields
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelX-20B
Vacuum Performance≤1×10⁻¹¹ Torr
Vibration Level3–5 nm RMS (typical)
Base Temperature~4 K (with DE-204/DE-210 cold head)
Cooling MethodHelium gas exchange
Cold Head OrientationVertical-down only
Bakeout CapabilityUp to 200 °C without breaking vacuum
ComplianceUHV-compatible welded metal seals (CF flanges), all-elastomer-free construction
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelLT3M
Instrument TypeVertical
Temperature Stability±50 mK
Temperature Uniformity50 mK
Operating Temperature Range<2 K (pumped) to 350 K
Base Temperature1.7 K (with pumping), 4.2 K (liquid helium bath)
Helium Consumption0.7 L/hr at 4.2 K
Cooling Power0.5 W @ 4.2 K, 3.0 W @ 20 K, 7 W @ 50 K
Vibration LevelSub-ångström (sub-Å) RMS
Vacuum CompatibilityUHV ≤1×10⁻¹¹ Torr
Flange OptionsStandard 4.5" CF, Optional 6" or 8" CF
Radiation ShieldNickel-plated OFHC copper, positioned 0.125" from cold tip
CustomizationExtendable cold finger, rigid support mounts, custom sensor wiring, sample stage configurations
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelX-4-1
Cooling MethodGifford-McMahon (GM) Cryocooler
Temperature Range4 K to 350 K (optional: 2.7 K low-temp stage / 800 K high-temp upgrade)
ConfigurationVertical
Sample Chamber Diameter1.5 in (38 mm) optical access
Standard Viewports4 radial + 1 optional bottom
Structural MaterialWelded Stainless Steel
Cryocooler OptionsDE-202 or DE-204 series
ComplianceDesigned for GLP/GMP-aligned lab environments, compatible with ASTM E2217 and ISO/IEC 17025 traceable calibration protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelX-12
Cooling Capacity Options4 K, 5.5 K, or 10 K (with DE-202/DE-204 cold head)
Vacuum Enclosure MaterialNon-magnetic anodized aluminum
Radiation ShieldPolished oxygen-free copper (OFHC), non-magnetic
Optical ApertureDMX-12 (1.62 in) or DMX-12B (1.37 in)
Standard Optical Window1-inch fused silica
Temperature SensingCalibrated silicon diode (±12 mK accuracy, 4-ft lead) + control-grade silicon diode (±0.5 K)
Electrical Feedthrough10-pin hermetic connector
Sample StageCustomizable non-magnetic mount for Hall/magneto-optical measurements
CompressorARS-2HW
Helium Transfer LinesTwo flexible cryogenic lines
ComplianceDesigned for operation inside narrow-gap electromagnets and superconducting magnets (e.g., split-pair, vertical-field, or horizontal-field configurations)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelCP-4
Instrument TypeIntegrated Circulating Chiller
Cooling MethodAir-Cooled
Temperature Control Range12–32 °C
Temperature Stability±0.1 °C
Refrigeration Capacity3.9 kW
Circulation Pump Pressure2.0 bar
Circulation Flow Rate6.3 L/min
Reservoir Volume1 L
Operating ModeContinuous
Power Supply200–230 V, 50/60 Hz
Ambient Operating Temperature12–32 °C
Storage Temperature−20 to +60 °C
Water Flow Connection3/8″ compression fitting
Airflow Requirement19.8 m³/min (700 SCFM)
Dimensions (L×W×H)483 × 533 × 617 mm
Net Weight36 kg (compressor unit), 39 kg (fully assembled)
Water QualitypH 6–8, total hardness < 85 ppm CaCO₃
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelLT4-FTIR
Operating Temperature Range4.2 K (liquid helium) to 77 K (liquid nitrogen)
Optical AccessDual high-purity quartz windows, 1.25″ clear aperture, F/1 field of view
Cooling MediumCompatible with both liquid helium and liquid nitrogen
Helium Consumption0.75 L/hr at 4.2 K
ConstructionAluminum cold stage, aluminum radiation shield, aluminum vacuum housing (DMX-1AL)
Temperature SensingTwo calibrated silicon diode thermometers (±0.5 K accuracy), one mounted on cold stage, one on sample holder with 4-ft lead
Electrical InterfaceHermetic 10-pin feedthrough, four test leads, integrated 36 Ω foil heater
Sample MountingFlat optical sample stage
ComplianceDesigned for integration into FTIR, Raman, photoluminescence, and magneto-optical spectroscopy systems per ISO/IEC 17025-aligned laboratory practice
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelLT3-OM-1
Cooling MediumLiquid Helium / Liquid Nitrogen
Temperature Range2 K (under pumping) to 350 K
Base Temperature≤4.2 K
Liquid Helium Consumption0.7 L/hr @ 4.2 K
Cool-down Time~20 min
ConfigurationVertical
Sample Chamber Diameter1.52 in (38.6 mm)
Vibration PerformanceUltra-low
Optical AccessCoaxial, Microscope-integrated
Vacuum HousingElectropolished Welded Stainless Steel
ComplianceDesigned for UHV-compatible optical microscopy environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelLT4
Operating Temperature Range4.2 K (liquid helium) to 77 K (liquid nitrogen)
Optical Window Diameter1.25 in (31.75 mm)
Window MaterialHigh-purity fused silica
Base Temperature Stability±0.5 K
Helium Consumption Rate0.75 L/hr at 4.2 K
Structural MaterialAluminum alloy
Sample Viewing AngleF/1 (broad field-of-view for optical collection)
Electrical Interface10-pin hermetic feedthrough + 4 dedicated test leads
Temperature SensingCalibrated silicon diode sensors (±0.5 K accuracy), dual-sensor configuration (cold stage + sample mount)
Standard AccessoriesDMX-1AL aluminum radiation shield & vacuum shroud, helium transfer line, aluminum instrument panel, Dewar adapter, two quartz windows, 36 Ω foil heater, temperature controller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelLN-400
Temperature Range77 K to 500 K (upgradable to 800 K)
Liquid Nitrogen Capacity0.4 L
Optical Window Diameter1.25 in (31.75 mm), High-Purity Fused Silica
Numerical Aperture Equivalentf/1.4
Temperature SensorCalibrated Silicon Diode (±0.5 K accuracy, dual placement: bath & sample stage)
Heating Element36 Ω Flat-Foil Heater
Electrical InterfaceHermetic 10-pin Feedthrough
Sample StageRemovable Flat Plate Mount
ControllerIntegrated PID Temperature Controller with RS-232/USB Interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelX-3-2
TypeVertical
Cooling MethodHelium-Free Closed-Cycle Refrigeration
ConfigurationIntegrated with Fluorescence Spectrometers (e.g., Edinburgh Instruments)
Sample PositioningMotorized XYZ Translation Stage
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelLT3B-OM
Operating Temperature Range1.7 K (pumped He) to 300 K
Base Temperature (liquid helium)4.2 K
Helium Consumption0.7 L/hr at 4.2 K
Compatible CryogensLiquid helium (4.2 K), pumped helium (1.7 K), liquid nitrogen (77 K)
Vibration LevelNanoscale (sub-10 nm RMS, isolated from cryogen flow)
Bakeable to150 °C
SealingOxygen-free copper gaskets on all UHV flanges
Optical AccessInterchangeable windows with customizable materials (e.g., fused silica, CaF₂, sapphire)
Sample StageFlat, electrically isolated, height-adjustable (±1.52″ range)
Temperature SensingCalibrated silicon diode (±12 mK accuracy, 4-ft lead), control-grade silicon diode (±0.5 K), 36 Ω foil heater
Electrical Feedthrough10-pin hermetic connector
Radiation ShieldNickel-plated OFHC copper
IncludedLT3-OM cold stage, coaxial flow helium transfer line, stainless-steel instrument panel, dewar adapter, flow control board, radiation shield
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelX-2 XRD-1
Instrument TypeVertical
Cooling MethodHelium-Free Closed-Cycle Refrigeration
Compatible GoniometersHuber 512.12, Huber 5020, Newport
Compatible DiffractometersBruker D8, D500, D5000, Agfa/Seifert XRD-3003, STOE
Window OptionsBeryllium Dome (DMX-2D), Beryllium Window, Kapton Window
Cold HeadDE-202
Mounting InterfaceCS202*G-DMX-2D
Application FocusX-ray Diffraction at Cryogenic Temperatures
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelDE-215
Cooling Capacity1.5 W at 4.2 K
Cold Head TypeTwo-Stage Gifford-McMahon Cryocooler
Operating EnvironmentClosed-Cycle, Helium-Gas-Driven
Flange OptionsMRI Universal Flange, ISO-KF Flange
Standard ConfigurationDE-215S Cold Head + ARS-10HW Compressor + Two Flexible High-Pressure Helium Transfer Lines
Vibration Level< 5 µm peak-to-peak (at cold tip, 4.2 K)
Acoustic Noise< 65 dB(A) at 1 m
Maintenance Interval≥ 15,000 hours compressor runtime
ComplianceCE-marked, RoHS-compliant, UL-listed components
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelOrca Mixed Gas JT
Cooling PrincipleJoule-Thomson (JT) Expansion Cycle
Base Temperature80 K
RefrigerantMixed Gas (N₂/Ar or similar blend)
Compressor TypeAir-Cooled
Vibration Level< 1 µm RMS (typical)
Maintenance RequirementNone (no moving parts in cold head)
Standard ConfigurationMR-80 Cold Head, Air-Cooled Compressor, Two Flexible High-Pressure Transfer Lines
ComplianceCE, RoHS, UL Listed (Compressor Unit)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelX-1AL-2
TypeVertical
Temperature Range4 K to 800 K
Base Temperature≤4 K (with optional 1.5 K insert)
Optical AccessFully integrated optical path with coaxial alignment capability
Software InterfaceGuided, modular GUI for automated temperature ramping, dwell, and synchronization with external spectrometers
Sample CompatibilitySolid (powder, thin film), liquid, and mounted substrates
ModularitySupports cryogenic optical modules including confocal microscopy, time-resolved photoluminescence (TRPL), anisotropy, quantum yield, and variable-temperature spectroscopy
ComplianceDesigned for GLP/GMP-aligned labs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelDE204
Cooling Capacity2.5 W @ 20 K (standard configuration)
Base Temperature≤4.2 K (with optional 4K cold head)
Cold HeadDE-204AF
CompressorARS-4HW
Helium Transfer LinesTwo flexible high-pressure lines
ComplianceCE, RoHS, UL-listed components
Operating Noise Level<65 dB(A)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARS
OriginUSA
ModelX-20-2
ConfigurationVertical
Cooling MethodClosed-cycle mechanical refrigeration (no liquid helium required)
Temperature Range2.0 K to 350 K (typical base temperature ≤2.1 K)
Vibration Amplitude<5 nm RMS (at sample stage, 1–100 Hz band)
Cooling Power≥15 mW at 2.2 K
Mounting InterfaceStandard CF-63 or custom flange options
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0