Transmission Electron Microscope
Filter
Showing all 5 results
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | CRYO ARM™ 200 II (JEM-Z200CA) |
| Acceleration Voltage | 200 kV |
| Magnification Range | ×100 to ×1,000,000 |
| Spherical Aberration Coefficient (Cs) | 1.5 mm |
| Chromatic Aberration Coefficient (Cc) | 1.8 mm |
| Specimen Temperature | ≤100 K |
| Sample Storage Capacity | Up to 12 cryo-samples |
| Energy Filter | Integrated Omega-type Energy Filter |
| Optional Software | JEOL Automated Data Acquisition System (JADAS) |
| Brand | JEOL (Japan Electron Optics Laboratory) |
|---|---|
| Origin | Japan |
| Model | JXA-iHP100 |
| Acceleration Voltage | 0–30 kV (0.1 kV step) |
| Beam Current Range | 10⁻¹² – 10⁻⁵ A |
| Beam Current Stability | ±5% / h, ±0.3% / 12 h (W) |
| Secondary Electron Resolution | 6 nm (W), 5 nm (LaB₆) at WD = 11 mm, 30 kV |
| Scan Magnification | ×40 – ×300,000 (WD = 11 mm) |
| Max. Image Resolution | 5,120 × 3,840 pixels |
| Display | Dual LCDs (1,280 × 1,024 each) for EPMA and SEM/EDS operation |
| Optical Microscope Resolution | ~1 µm |
| Depth of Field | ~1 µm |
| Vacuum System | Mechanical pump + turbomolecular pump + ion pump |
| Chamber Vacuum | <8.0 × 10⁻⁴ Pa |
| Gun Vacuum | <9.0 × 10⁻⁵ Pa |
| Elemental Detection Range | WDS: Be (optional) to U |
| EDS | B to U |
| WDS Wavelength Range | 0.087–9.3 nm |
| EDS Energy Range | 0–20 keV |
| WDS Spectrometer Channels | 1–5 (configurable) |
| EDS Detector | One SDD (Silicon Drift Detector), fanless option available |
| Max. Sample Size | 100 mm × 100 mm × 50 mm (H) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China-manufactured under Thermo Fisher global quality system) |
| Model | Talos F200S G2 |
| Price | Upon Request |
| Acceleration Voltage | 200 kV |
| HRTEM Line Resolution | 0.10 nm |
| Minimum Detectable Feature Size | 0.16 nm |
| Field Emission Gun (FEG) Total Beam Current | >150 µA |
| EDS System | Dual in-column SDD Super-X detectors, windowless design with shutter protection |
| EDS Energy Resolution | ≤136 eV at Mn-Kα (10 kcps output) |
| EDS Mapping Pixel Dwell Time | Down to 10 µs |
| EDS Solid Angle | 0.45 sr |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Netherlands |
| Model | Tundra |
| Acceleration Voltage | 200 kV (standard configuration) |
| Magnification Range | ×50 to ×1,000,000 |
| Specimen Stage | Single-tilt cryo-transfer holder with automated loading |
| Minimum Information Limit | ≤3.5 Å under optimal conditions (SPA workflow) |
| Footprint | 3.2 m × 2.8 m (including shielding and service clearance) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific™ Glacios™ |
| Price Range | USD $2.5M–$3.8M (FOB) |
| Accelerating Voltage | 80–200 kV |
| Magnification | Up to 10,000,000× |
| Electron Source | 200 kV X-FEG (Cold Field Emission Gun) |
| Automation | Integrated Autoloader with cryo-transfer compatibility |
| Software Platform | EPU v3.x for Single-Particle Analysis (SPA) |
| Detector Compatibility | Supports Direct Electron Detectors (e.g., Falcon 4, Gatan K3) and Volta Phase Plate (VPP) |
| Footprint | < 8 m² (including service access) |