| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TBD5 DS1390 |
| Output Signal | 4–20 mA (configurable linear or control mode) |
| Communication Interfaces | RS232, RS485 (selectable baud rate), IEEE 1451.1 NCAP compliant |
| Enclosure Rating | NEMA 6P / NEMA 7 / NEMA 8 / NEMA 9 / IP67 |
| Explosion Protection | Intrinsic Safety (Ia), Class I Div 1 Groups A/B/C/D |
| Operating Temperature | −40 to +85 °C (max 125 °C transient) |
| Storage Temperature | −51 to +125 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Power Supply | 12/24 V DC ±20%, <100 mW total consumption |
| Repeatability | ±0.02% FS |
| Accuracy | <±1.0% of full scale |
| Response Time | <100 ms |
| Long-Term Stability | ±1% FS per year |
| Wetted Materials | 316SS or 304 stainless steel |
| Measuring Principle | Dual-point differential pressure (ΔP) with temperature-compensated density calculation |
| Probe Immersion Length Options | 30 cm, 60 cm, or 30 cm (model-dependent) |
| Max Working Pressure | 0.0345–0.21 MPa (model-dependent) |
| Display Interface | Built-in 2×16 character LCD driver with external keypad (no PC required) |
| Data Logging | Configurable intervals (hourly,定点, daily, monthly, quarterly, annual) |
| Temperature Compensation | Embedded real-time thermal correction algorithm |
| Digital Outputs | 2 × open-collector 5 V switches |
| Real-Time Clock | Integrated |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM6208D |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Detection Range | 0–2000 ppm |
| Accuracy | ±(50 ppm + 5% of reading) |
| Resolution | 1 ppm |
| Response Time (T90) | ≤30 s |
| Warm-up Time | <180 s |
| Output Signal | 4–20 mA / 0–10 V (selectable) |
| Operating Temperature | −10 to +50 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power Supply | 24 VAC ±10% or 24 VDC ±10% |
| Average Current Consumption | ≤40 mA |
| Standby Current | ≤20 mA |
| Mounting Hole Pitch | 60 mm |
| Dimensions | 86 × 120 × 185 mm |
| Service Life | ≥15 years |
| Compliance | RoHS, CE (EMC & LVD), ISO 9001-manufactured |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM6208W |
| Measurement Principle | NDIR (Non-Dispersive Infrared) |
| Measurement Range | 0–2000 ppm |
| Accuracy | ±(50 ppm + 5% of reading) |
| Resolution | 1 ppm |
| Refresh Rate | 1 s |
| Warm-up Time | <180 s |
| Response Time (T90) | ≤30 s |
| Operating Temperature | −10 to 50 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temperature | −20 to 70 °C |
| Supply Voltage | 24 VAC ±10% or 24 VDC ±10% |
| Average Current Consumption | ≤40 mA |
| Standby Current | ≤20 mA |
| Output Signal | 4–20 mA / 0–10 V (configurable) |
| Mounting Hole Pitch | 60 mm |
| Dimensions | 86 × 86 × 24.9 mm |
| Service Life | ≥15 years |
| Compliance | RoHS, CE-marked for industrial use |
| Calibration | ABC (Automatic Background Calibration) enabled |
| Brand | Cubic |
|---|---|
| Model | Gasboard-2503-NH₃ |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Gas | NH₃ |
| Measurement Range | 0–50 ppm |
| Accuracy | ±2% FS |
| Response Time (T90) | ≤20 s |
| Measurement Cycle | 1–3600 s |
| Output Interface | RS485 @ 12 V DC |
| Power Supply | 12 V DC |
| Average Power Consumption | ≤1 W |
| IP Rating | IP66 |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–100% RH (non-condensing) |
| Atmospheric Pressure | 101 kPa |
| Explosion Protection | UL Class I, Division 2 |
| Design Life | 10 years |
| Application | Livestock Housing Air Quality Monitoring |
| Brand | Hamilton |
|---|---|
| Origin | Switzerland |
| Model | H100 pH |
| Measurement Range | pH −2.00 to 16.00 |
| ORP | −1500 to +1500 mV |
| Temperature Input | Pt100 / Pt1000 / NTC 30 kΩ |
| Temperature Range | −20 to +150 °C |
| Temperature Resolution | 0.1 °C |
| Measurement Error | <1 mV |
| Analog Outputs | Dual 4–20 mA (floating, max 10 V) |
| Relay Output | Configurable (alarm/flush), 3 A / <250 VAC or 30 VDC |
| Housing Material | PBT |
| Enclosure Rating | IP65 / NEMA 4X |
| Power Supply | 24–230 V AC/DC |
| Display | 7-segment LCD with icons |
| Operating Humidity | 0–80% RH at ≤55 °C |
| FM Certification | Class I, Div. 2, Groups A/B/C/D & IIC, T4, Ta = 55 °C, Type 2 |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PHGF-28H |
| Price | Upon Request |
| pH Range | 0.00–14.00 pH |
| ORP Range | ±1800 mV |
| Temperature Range | −5 to +105 °C |
| Operating Sample Temp. | 5–60 °C |
| Max. Sample Pressure | < 0.1 MPa |
| Sample Flow Rate | 200 mL/min |
| Inlet Tubing | Ø6×1 mm stainless steel |
| Outlet Tubing | Ø10×1 mm stainless steel |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PHGF-43 |
| Pricing | Upon Request |
| Housing Material Options | PVC, CPVC, SS304, SS316 |
| Cleaning Function | None or Jet Flush |
| Pre-amplifier | Optional (Integrated or External) |
| Compatible Electrodes | FG-991 (pH) / ORP-1 (Redox) |
| Measurement Range | pH 0–14 |
| Process Temperature Range | 5–45 °C |
| Max. Pressure Rating | 0.6 MPa |
| Enclosure Protection | IP65 (Junction Box or High-Impedance Box) |
| Submersion Length Options | 0.5 m, 1.0 m, 1.5 m, 2.0 m, 2.5 m, 3.0 m (User-selectable) |
| Standard Cable Length | 20 m (Extended lengths available upon specification) |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PHGF-46 |
| Pricing | Available Upon Request |
| Flow Cell Configurations | P2N1, P2Y1, P3N1, P3Y1, P4N0, P4Y0, S1N1, S1Y1 |
| Pre-amplifier | Integrated (Y) or Not Integrated (N) |
| Compatible Electrodes | FG-991A (pH), FG-990 + T-819-A (pH/ORP combo), T-819-A (temperature) |
| Measuring Range | pH 0–14 |
| Sample Temperature Range | 0–55 °C (standard) |
| Max Process Pressure | 0.6 MPa |
| Housing Material Options | PVC (A=P), CPVC (A=C), SS304 (A=T), SS316 (A=S) |
| Flow Cell Types | FT-01 (inline straight), FS-02 (T-fitting), FX-03/FX-04 (angled insertion, FX-04 supports integrated Pt100 temperature sensor) |
| Inlet/Outlet Connections | 1", 1/2", 3/4" NPT or BSP |
| Tubing Inlet | Φ6×1 mm stainless steel or PVDF |
| Tubing Outlet | Φ10×1 mm stainless steel or PVDF |
| Standard Cable Length | 10 m (custom lengths available on request) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | 770MAX |
| Input Channels | 6 (up to 16 measurement results) |
| Sensor Types Supported | 8 (including pH/ORP, conductivity/resistivity, dissolved oxygen, ozone, TOC, flow, temperature, pressure, level) |
| Output Options | 4 or 8 analog outputs (0/4–20 mA), RS232 serial interface, up to 4 relay outputs (optional) |
| Display | Multi-line scrolling LCD with customizable parameter labeling |
| Power Supply | Universal AC 100–240 V, 50–60 Hz |
| Enclosure | 1/4 DIN, IP65-rated front panel, sealed rear cover |
| Calibration | NIST-traceable verification & calibration via optional 1875 Smart Calibrator |
| Smart Sensor Compatibility | Thornton intelligent sensors with embedded NVRAM for auto-recognition, calibration data storage, and plug-and-play operation |
| Measurement Units | 35 configurable units across parameters |
| Temperature Compensation | Integrated, parameter-specific algorithms |
| Data Timestamping | Internal real-time clock for all measurements and calibration events |