Tri-gas Incubator
Filter
Showing all 15 results
| Brand | ANAYN |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Air-Jacketed Tri-Gas Incubator |
| O₂ Concentration Range | 1–95% (v/v) |
| CO₂ Concentration Range | 0–20% (v/v) |
| Temperature Control Range | +3°C to +60°C |
| Temperature Uniformity | ±0.3°C (@37°C) |
| Temperature Stability | ±0.2°C (@37°C) |
| Humidity Level | ≥90% RH (passive water-jacket evaporation, uncontrolled) |
| Chamber Volume | 80 L |
| External Dimensions (W×D×H) | 640 × 650 × 1040 mm |
| Internal Dimensions (W×D×H) | 400 × 400 × 500 mm |
| Display | 5.0-inch capacitive touchscreen |
| CO₂ Sensor | NDIR infrared sensor |
| O₂ Sensor | Imported electrochemical sensor |
| Temperature Sensor | PT100 platinum resistance sensors (5-wall + door independent control) |
| Sterilization | UV lamp (programmable on/off) |
| Power Consumption | 400 W |
| Gas Inlets | Dedicated high-purity N₂, O₂, and CO₂ ports with solenoid valve control |
| Key Features | IR-based CO₂ sensing |
|---|---|
| Temperature range | Rt+3–60 °C |
| Temp. uniformity | ±0.3 °C @ 37 °C |
| CO₂ range | 0–20% (±0.1% accuracy) |
| O₂ range | 1–95% (±0.3% accuracy) |
| External dimensions | 550×530×890 mm |
| Construction | 304 stainless steel interior |
| Gas supply logic | N₂/CO₂ blending for hypoxia (<19.8% O₂) |
| Compliance | Designed for ISO 13485-aligned lab environments, GLP-compliant operation support |
| Brand | ANYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | CYSQ-80 |
| Type | Air-Jacketed Tri-Gas Incubator |
| O₂ Range | 1–95% (v/v) |
| O₂ Accuracy | ±0.3% (v/v) |
| Temperature Range | +3 to +60 °C |
| Temp Uniformity | ±0.3 °C (@37 °C) |
| Temp Stability | ±0.2 °C (@37 °C) |
| CO₂ Range | 0–20% (v/v) |
| CO₂ Accuracy | ±0.1% (v/v) |
| Humidity | ≥90% RH (passive water-jacket evaporation, uncontrolled) |
| Chamber Volume | 80 L (customizable) |
| CO₂ Sensor | IR-based |
| O₂ Sensor | Electrochemical (imported) |
| Temp Sensor | PT100 (imported) |
| Sterilization | UV lamp |
| Power | 400 W |
| Chamber Dimensions (W×D×H) | 400×400×500 mm |
| External Dimensions (W×D×H) | 540×520×790 mm |
| Shelf | 1 stainless steel shelf (304) |
| Compliance | Designed for GLP-aligned cell culture workflows |
| Brand | ANYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | CYSQ-80-III |
| Chamber Volume | 80 L |
| Temperature Range | +3 to +60 °C |
| Temperature Uniformity | ±0.3 °C (@37 °C) |
| Temperature Stability | ±0.2 °C (@37 °C) |
| CO₂ Range | 0–20 % vol, Accuracy: ±0.1 % |
| O₂ Range | 1–95 % vol, Accuracy: ±0.3 % |
| Humidity | ≥90 % RH (passive water-jacket evaporation, uncontrolled) |
| Gas Control Method | IR sensor for CO₂ |
| Sterilization | UV lamp |
| Display | 5.0-inch capacitive touchscreen |
| Dimensions (W×D×H) | 640 × 650 × 1040 mm |
| Power Consumption | 400 W |
| Compliance | Designed for GLP-compliant cell culture workflows |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Water-Jacketed Tri-Gas Incubator |
| O₂ Range | 1–95% ±0.3% |
| CO₂ Range | 0–20% ±0.1% |
| Temperature Range & Stability | RT+3°C to 60°C |
| Humidity | ≥90% RH (natural evaporation from 304 stainless steel water pan) |
| Capacity | 100 L |
| Dimensions (W×D×H) | 550 × 530 × 890 mm |
| Display | Capacitive Touchscreen Interface |
| Gas Control Logic | Dual-gas mixing with N₂/O₂/CO₂ prioritization for cross-interference minimization |
| Sterilization | UV lamp + optional 90°C high-temperature humidified sterilization |
| Air Circulation | Micro-airflow system with six-sided chamber heating + independent door temperature control |
| Compliance | Designed for GLP-compliant cell culture workflows |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AYJ-KB160B |
| Instrument Type | Water-Jacketed Tri-Gas Incubator |
| O₂ Concentration Range | 1–95% ±0.3% |
| Temperature Control Range & Accuracy | RT+3°C to 60°C |
| Temperature Uniformity | ±0.3°C (@37°C) |
| CO₂ Concentration Range & Accuracy | 0–20% ±0.1% |
| Humidity Control | ≥90% RH (natural evaporation) |
| Chamber Capacity | 160 L |
| External Dimensions | 640 × 620 × 940 mm |
| Standard Configuration | 5.7-inch color touch screen |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Model | AYJ-KB50B |
| Type | Water-Jacketed Tri-Gas Incubator |
| Chamber Capacity | 50 L |
| Dimensions (W×D×H) | 430 × 460 × 650 mm |
| Temperature Range & Accuracy | RT+3°C to 60°C |
| Temperature Uniformity | ±0.3°C @ 37°C |
| CO₂ Control Range & Accuracy | 0–20% ±0.1% |
| O₂ Control Range & Accuracy | 1–95% ±0.3% |
| Humidity Control | ≥90% RH (natural evaporation from stainless steel water pan) |
| Gas Sensors | IR-based CO₂ sensor |
| Display | Touchscreen interface |
| Sterilization | UV lamp |
| Construction | 304 stainless steel interior with rounded corners |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Model | AYJ-KB50B |
| Type | Water-jacketed tri-gas incubator |
| Capacity | 50 L |
| Dimensions (W×D×H) | 430 × 460 × 650 mm |
| Temperature Range & Accuracy | RT+3°C to 60°C |
| Temperature Uniformity | ±0.3°C (@37°C) |
| CO₂ Control Range & Accuracy | 0–20% vol, ±0.1% |
| O₂ Control Range & Accuracy | 1–95% vol, ±0.3% |
| Humidity | ≥90% RH (natural evaporation from stainless steel water pan) |
| Display | Touchscreen interface |
| Gas Sensors | IR-based CO₂ sensor |
| Chamber Material | 304 stainless steel with rounded corners |
| Sterilization | UV lamp |
| Safety | Independent over-temperature cut-off relay, dual-limit thermal protection, automatic gas shutoff upon door opening |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Model | AYJ-KB80B |
| Type | Water-jacketed tri-gas incubator |
| O₂ Range | 1–95% ±0.3% |
| CO₂ Range | 0–20% ±0.1% |
| Temperature Range | RT+3–60°C |
| Temp Uniformity | ±0.3°C @ 37°C |
| Humidity | ≥90% RH (natural evaporation from stainless steel water pan) |
| Capacity | 80 L |
| Dimensions (W×D×H) | 540×520×790 mm |
| Display | Touchscreen interface |
| Gas Sensors | IR-based CO₂ sensor |
| Sterilization | UV lamp |
| Construction | 304 stainless steel interior with rounded corners |
| Brand | Chuanheng Instrument |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Air-Jacketed Tri-Gas Incubator |
| O₂ Range | 0.1–95% vol (±0.3% accuracy) |
| Temperature Range | 5–60°C (±0.2°C stability at 37°C, ±0.8°C uniformity) |
| CO₂ Range | 0–20% vol (±0.1% accuracy, IR sensor-based) |
| Humidity Range | 50–95% RH |
| Capacity Options | 50 L / 80 L / 100 L / 160 L / 200 L |
| Standard Configuration | UV Sterilization, PT100 Temperature Sensing, Electromagnetic Gas Valve Interlock, Micro-Circulation Airflow System, Touchscreen Interface (5″ LCD), Dual-Stage Overtemperature & Gas Safety Cutoffs |
| Brand | Chuanyi Instruments (Hangzhou Chuanyi Electronic Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Instrument Type | Air-Jacketed Tri-Gas Incubator |
| O₂ Range | 1–95% (v/v), programmable in 0.1% increments |
| CO₂ Range | 0–20% (v/v), ±0.1% accuracy |
| Temperature Range | RT+3°C to 60°C, ±0.1°C setpoint stability |
| Temperature Uniformity | ±0.3°C at 37°C |
| Humidity | ≥90% RH (passive humidity maintenance via integrated water pan |
| Chamber Volume | 50 L |
| External Dimensions (W×D×H) | 430 × 460 × 650 mm |
| Display & Interface | 7-inch capacitive TFT touchscreen with multi-language UI (English default) |
| Gas Delivery | Triple independent mass flow controllers (MFCs) for O₂, CO₂, and N₂ |
| Certifications | CE-marked per IEC 61010-1 |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed Tri-Gas Incubator |
| Temperature Range & Accuracy | RT+5°C to 60°C, ±0.1°C |
| CO₂ Control Range & Accuracy | 0–20%, ±0.1% |
| O₂ Control Range & Accuracy | 1–95%, ±0.2% |
| Humidity Control | ≥90% RH (natural evaporation, unregulated) |
| Capacity | 160 L |
| External Dimensions (W×D×H) | 500 × 500 × 650 mm |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 550 W |
| Internal Chamber Dimensions | 500 × 500 × 650 mm |
| Standard Accessories | 2 adjustable stainless-steel shelves, HEPA filter, UV sterilization lamp, removable water pan |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed Tri-Gas Incubator |
| O₂ Range | 1–95%, ±0.2% |
| CO₂ Range | 0–20%, ±0.1% |
| Temperature Range | RT+5°C to 60°C, ±0.1°C control resolution, ±0.2°C stability |
| Humidity | Natural evaporation via removable water pan, ≥90% RH (unregulated) |
| Capacity | 50 L |
| External Dimensions | 345 × 355 × 410 mm |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 350 W |
| Internal Chamber Material | Electropolished stainless steel (304), electrochemically passivated |
| Filtration | Integrated HEPA filter (H14 class, ≥99.995% @ 0.3 µm) with real-time filter life monitoring |
| Sterilization | Built-in UV-C lamp (254 nm), programmable cycle, full-chamber irradiation including fan blades, sensor surfaces, and humidification pan |
| Gas Control Logic | Adaptive N₂ balancing algorithm ensuring CO₂ + O₂ + N₂ = 100% |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Air-Jacketed Tri-Gas Incubator |
| Model | TGC-80 |
| Temperature Range & Accuracy | RT+5°C to 60°C, ±0.1°C |
| CO₂ Control Range & Accuracy | 0–20%, ±0.1% |
| O₂ Control Range & Accuracy | 1–95%, ±0.2% |
| Humidity | ≥90% RH (natural evaporation, unregulated) |
| Capacity | 80 L |
| Internal Dimensions | 400 × 400 × 500 mm (W × D × H) |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 400 W |
| Filtration | Integrated HEPA filter |
| Sterilization | UV lamp system |
| Gas Sensors | IR-based CO₂ sensor |
| Heating | Six-sided air-jacketed heating with door heating |
| Air Circulation | Low-turbulence micro-circulation fan system |
| Safety | Dual-door structure with heated inner glass, multi-level alarm logic (temperature deviation, gas concentration drift, door-open duration, sensor fault) |
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Model | MCP-170G |
| Chamber Volume | 170 L |
| External Dimensions (W×D×H) | 670 × 825 × 920 mm |
| Internal Dimensions (W×D×H) | 490.5 × 560 × 620.5 mm |
| Temperature Range | Ambient +5°C to 55°C |
| Temperature Uniformity | ≤ ±0.3°C |
| Temperature Control Accuracy | < ±0.1°C |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% |
| O₂ Range | 1–20.7% |
| O₂ Control Accuracy | ±0.5% |
| O₂ Sensor Type | Zirconia-based |
| CO₂ Sensor Type | Infrared (IR) |
| Humidification | Integrated 3-L Water Reservoir |
| Heating Method | Direct-heated Air Jacket |
| HEPA Filtration | ISO Class 5 (100) recovery in ≤5 min after 30-sec door opening |
| Max. Power Consumption | 1100 W |
| Shelf Load Capacity | 12 kg per shelf |
| Standard Shelves | 3 (up to 7 optional) |
| Shelf Sizes | 450 × 485 mm (large), 450 × 440 mm (small) |
| Alarm Functions | Ambient temperature, chamber temperature, CO₂/O₂ concentration, water level |
| O₂ Recovery Time (after 30-sec door opening) | 50 min (from 1.0% target), 25 min (from 5.0% target) |