| Brand | Acoulab |
|---|---|
| Origin | South Korea |
| Model | SAM-CYGNUS |
| Instrument Type | Digital |
| Wafer Compatibility | 4" and 6" |
| Ultrasonic Transducer Frequency Range | 1–500 MHz |
| A/D Sampling Rate | 2 GHz |
| Bandwidth | 1 GHz |
| XY Repeatability | ±2 µm |
| Z-Scan Range | 70 mm |
| Z-Resolution | 2.5 µm |
| Scan Modes | A-scan, C-scan, T-scan, X-scan (multi-layer C-scan) |
| Integrated Systems | Wafer Map module, BCR reader, Pre-aligner, Spin Coater, Water Jet Scanning, Safety Interlock & Alarm System |
| Motor Drive | High-precision linear servo motors |
| Acoustic Coupling | Water jet coupling |
| Brand | Acoulab |
|---|---|
| Origin | South Korea |
| Model | SAM-DENEB |
| Instrument Type | Digital Scanning Acoustic Microscope |
| Scan Range (X-Y) | 350 mm × 350 mm |
| Spatial Resolution (X-Y) | 0.5 µm |
| Ultrasonic Transducer Frequency Range | 1–500 MHz |
| A/D Sampling Rate | 2 GHz |
| Analog Bandwidth | 1 GHz |
| X-Y Scan Speed | 1000 mm/s |
| X-Y Repeatability | ±0.5 µm |
| Z-Axis Scan Range | 70 mm |
| Z-Axis Resolution | 2.5 µm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Form Factor | PCI Slot-Based Mainframe |
| Channel Capacity | Up to 112 Channels (Configurable via PCI-8 or PCI-2 AE Acquisition Cards) |
| Compliance | Designed for ASTM E1316, ISO 12713, and EN 1330-9 Conformance |
| Interface | PCI Express Backplane with Synchronized Sampling Architecture |
| Power Supply | Industrial-grade 100–240 VAC, 50/60 Hz |
| Operating Temperature | 0–50 °C |
| Storage Temperature | –20–70 °C |
| Dimensions (W×D×H) | 483 × 500 × 177 mm (Standard 4U Rack-Mount Chassis) |
| Weight | ≤18 kg |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer | Analysis Instruments, Inc. |
| Type | Imported |
| Model | GN1500HS |
| Pricing | Available upon Request |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Remote-UT |
| Instrument Type | Digital Ultrasonic Flaw Detector |
| Dimensions (Module) | 25 × 15 × 7.5 cm |
| Architecture | Embedded PC-based Distributed System |
| Signal Interface | Gigabit Ethernet |
| Compliance | ASTM E317, ISO 16810, EN 12668-1/2/3, ASME BPVC Section V |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer | Analysis, Inc. |
| Product Type | Imported |
| Model | TCP Ultrasonic C-Scan System |
| Pricing | Available Upon Request |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | U-AT |
| Instrument Type | Digital |
| Flaw Detection Method | Pulse-Echo |
| Waveform | Pulsed Ultrasonic |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Model | UPK-T156 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Scan Envelope | 4000 × 1500 × 900 mm |
| Gain Range | 0–110 dB |
| Vertical Linearity | ≤2% |
| Horizontal Linearity | ≤2% |
| Dynamic Range | ≥95 dB |
| Transducer Configuration | Single-Crystal or Through-Transmission |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Model | UPK-T24 |
| Scanning Range | 600 × 450 × 300 mm |
| Gain Range | 0–110 dB |
| Vertical Linearity | ≤2% |
| Horizontal Linearity | ≤2% |
| Dynamic Range | ≥95 dB |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Transducer Configuration | Single-Crystal or Through-Transmission |
| Brand | Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | UPK-T48 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Scan Envelope | 1200 × 900 × 600 mm |
| Gain Range | 0–110 dB |
| Vertical Linearity | ≤2% |
| Horizontal Linearity | ≤2% |
| Dynamic Range | ≥95 dB |
| Transducer Configuration | Single-Crystal or Through-Transmission |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Price | Upon Request |
| Operating Temperature Range | -200 °C to +350 °C |
| Battery Life | 3–4 years (typical continuous operation) |
| Communication Protocols | WirelessHART (IEC 62591), Zigbee |
| Channels | 4 independent ultrasonic measurement channels |
| Environmental Rating | IP67-rated enclosure |
| Dual-Sensor Capability | Simultaneous thickness + ambient temperature measurement |
| Probe Compatibility | Single-crystal and dual-crystal ultrasonic transducers |
| Data Transmission | Secure, encrypted wireless transmission to local SCADA or cloud-based asset integrity platforms |
| Brand | Ansys |
|---|---|
| Origin | USA |
| Manufacturer | Ansys, Inc. |
| Product Type | Imported |
| Model | Custom |
| Instrument Type | Digital Ultrasonic Flaw Detector |
| Inspection Method | Pulse-Echo & Through-Transmission |
| Waveform Type | Pulsed Ultrasonic |
| Scan Envelope | 1800 mm × 1800 mm × 1200 mm |
| Transducer Configuration | Single-Crystal Probes (Pulse-Echo and Through-Transmission Modes) |
| Compliance | GE Aviation Approved Design |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | IN-CTS3 |
| Instrument Type | Digital Ultrasonic Flaw Detector |
| Inspection Method | Pulse-Echo & Through-Transmission |
| Waveform Mode | Continuous Wave (CW) and Pulsed Wave (PW) |
| Application Sectors | Aerospace, Power Generation, Petrochemical, Pressure Vessel, Rail Transit, Automotive, Structural Steel |
| Scan Range | 0–10000 mm |
| Gain Adjustment | 0–110 dB |
| Vertical Linearity Error | ≤2.5% |
| Horizontal Linearity Error | ≤0.1% |
| Dynamic Range | ≥32 dB |
| Resolution | ≥40 dB |
| Probe Types Supported | Single-Crystal & Dual-Crystal |
| Frequency Range | 0.5–20 MHz |
| Sensitivity Margin | ≥60 dB (200 mm depth, Ø2 mm flat-bottom hole) |
| Material Sound Velocity Range | 1000–9999 m/s |
| Echo Suppression | 0–80% |
| Operating Temperature | −27°C to +70°C |
| Dimensions | 240 × 160 × 40 mm |
| Weight | 1.3 kg |
| A-scan Storage Capacity | 980 frames |
| Channel Memory | 16 user-configurable inspection channels |
| DAC/AVG Curve Generation | Automatic (via standard test blocks) |
| Weld Diagram Modes | I-, V-, U-, and X-type schematic overlays |
| Defect Sizing | Equivalent reflector diameter (φ) calculation |
| Data Interface | USB 2.0 for PC connectivity and report export |
| Display | High-brightness TFT LCD, sunlight-readable |
| Brand | EVIDENT |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OmniScan X4 128:128PR |
| Pricing | Upon Request |
| Brand | Analysis |
|---|---|
| Country of Origin | Germany |
| Model | KSI V-700E |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform | Pulsed Ultrasound |
| Maximum Scan Area | 700 mm × 1000 mm |
| Gain Range | 0–120 dB |
| Dynamic Range | ≥40 dB |
| Resolution | ≥32 dB |
| Transducer Configuration | Single-Crystal |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | V-400E |
| Detection Method | Pulse-Echo Mode |
| Waveform Type | Pulsed Ultrasound |
| Maximum Scan Speed | 2000 mm/s |
| Minimum Scan Area | 200 µm × 200 µm |
| RF Bandwidth | 500 MHz |
| Probe Configuration | Single Transducer (Standard) |
| Frequency Range (Optional Probes) | 100–2000 MHz |
| Axial Resolution (Typical) | <100 nm (with Nano-series transducers) |
| Integrated Optical Microscopy | Yes (Inverted & Epi-Illumination Configurable) |
| Compliance | ASTM E1783, ISO 16932, IPC-J-STD-035, JEDEC JESD22-A108 |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 600 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform | Pulsed Ultrasonic |
| Compliance | EN12668-1 |
| Weight | 1.68 kg |
| Display | Full VGA (640 × 480), Transflective LCD |
| PRF | 10–2000 Hz |
| Pulse Voltage | 100–400 V |
| Pulse Width | 25–5000 ns (adjustable via PerfectSquare™) |
| Receiver Bandwidth | 0.2–26.5 MHz |
| Digital Filters | 8 standard settings |
| Battery Life | ≥12 h (Li-ion) |
| IP Rating | IP66 (rotary encoder config) / IP67 (keypad config) |
| Operating Temperature | –10 °C to +50 °C |
| Data Storage | 50,000 onboard IDs + 2 GB microSD card |
| Interface | USB OTG, RS-232, VGA output, optional analog output |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 650 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasound |
| Compliance | EN 12668-1:2010 |
| IP Rating | IP66 (rotary knob), IP67 (keypad) |
| Operating Temperature | –10 °C to 50 °C |
| Weight | 1.6 kg (with Li-ion battery) |
| Display | Full VGA (640 × 480) transflective color LCD |
| Battery Life | >15 hours |
| PRF | 10–2000 Hz |
| Pulse Energy | 100–400 V |
| Pulse Width | 25 ns–5000 ns (PerfectSquare™) |
| Receiver Bandwidth | 0.2–26.5 MHz |
| Digital Filters | 30 standard, including 7 EN-compliant |
| Gain Range | 0–110 dB |
| Dynamic Range | 110 dB (DAC) |
| A-Scan Memory | 100,000 encoded records |
| Storage | Standard 2 GB microSD card |
| Interfaces | USB OTG, VGA, RS-232, analog output (optional), digital I/O, encoder input |
| Probe Connectors | Two BNC or LEMO No.1 |
| Certifications | MIL-STD-810F (shock/vibration/explosion-proof), NFPA 70 Class I, Div. 2, Group D |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 6LS |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Compliance Standard | NB/T 47013.3–2015 |
| IP Rating | IP65/IP67 |
| Operating Temperature | –10 °C to 50 °C |
| Weight | 890 g (with Li-ion battery) |
| Display | Full VGA (640 × 480), Transflective Color LCD |
| Battery Life | Up to 6 hours |
| PRF Range | 10–2000 Hz |
| Pulse Voltage | Up to 400 V |
| Receiver Bandwidth | DC–26.5 MHz (–3 dB) |
| Digital Filters | 8 preset configurations |
| Gate Count | 2 independent measurement gates |
| DAC Points | Up to 50, 110 dB dynamic range |
| Data Storage | 100,000 waveforms with ID tags |
| Interface | Dual USB (Host + Client), Digital Video Output |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 6LT |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform | Pulsed Ultrasonic |
| Compliance | EN 12668-1:2010 |
| Environmental Rating | IP65/IP67 |
| Weight | 890 g |
| Display | Full VGA (640 × 480) Transflective Color LCD |
| Battery Life | Up to 6 hours |
| Operating Temperature | –10 °C to 50 °C |
| PRF Range | 10–2000 Hz |
| Pulse Voltage | 100–400 V |
| Receiver Bandwidth | DC–26.5 MHz (standard), 0.2–26.5 MHz (EN-compliant) |
| Digital Filters | 8 standard settings |
| Data Storage | 100,000 IDs |
| Connectivity | USB 1.1 host, USB 2.0 client, optional Wi-Fi module |
| Software Compatibility | GageView Pro, Olympus Scientific Cloud |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | FOCUS PX / PC / SDK |
| Phased Array Channels | 16:64PR, 16:128PR, 32:128PR |
| Conventional UT Channels | 4 dedicated |
| Max Simultaneous Units | 4 |
| Data Throughput | up to 60 MB/s (4 units) |
| A-scan Rate | up to 20,000 @ 12-bit resolution (750 points/A-scan) |
| Pulse Voltage Range | PA: 4–115 V |
| UT | 50–190 V |
| Gain | PA: 80 dB (46 dB analog + 34 dB digital) |
| UT | 120 dB digital |
| Pulse Width | PA: 30–500 ns (2.5 ns step) |
| UT | 30–1000 ns (2.5 ns step) |
| Bandwidth (−3 dB) | PA: 0.6–17.8 MHz |
| UT | 0.25–28 MHz |
| Beam Count | up to 1024 |
| PRF | 1 Hz–20 kHz |
| Real-time Averaging | PA: 1–16 |
| UT | 1–64 |
| Gate Count | 4 detection + 1 encoder sync |
| Enclosure Rating | IP65 |
| Operating Temperature | up to 40 °C |
| Dimensions (with housing) | 30.7 × 13.5 × 23.6 cm |
| Weight (with housing) | 4.8 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Sensor Highway II / III |
| Instrument Category | Acoustic Emission (AE) & Multi-Parameter Structural Health Monitoring System |
| Operating Temperature Range | -35°C to +70°C |
| Power Supply | 10–28 VDC or 95–250 VAC |
| Power Consumption | 15 W (typical) |
| Dimensions | 40 cm × 50 cm × 20 cm |
| AE Channels | Up to 16 (expandable via four 4-channel micro-AE cards) |
| AE Frequency Bandwidth | 1 kHz – 1 MHz |
| Vibration Bandwidth | 1 Hz – 20 kHz |
| A/D Resolution | 18-bit |
| Sampling Rate | 20 MS/s (AE), 10 kS/s (16 low-speed external parameter channels) |
| IP Rating | IP67-rated enclosure (for outdoor deployment) |
| Communication Interfaces | Gigabit Ethernet, RS-232, RS-422, USB, CompactFlash |
| Brand | Acoulab |
|---|---|
| Origin | South Korea |
| Model | SAM-SPICA |
| Instrument Type | Digital Scanning Acoustic Microscope |
| Transducer Frequency Range | 1–500 MHz |
| A/D Sampling Rate | 500 MHz |
| Signal Bandwidth | 1 GHz |
| XY Scan Speed | 1000 mm/s |
| XY Repeatability | ±0.5 µm |
| Scan Modes | A-scan, B-scan, C-scan, X-scan (multi-layer C-scan) |
| Sample Handling | Motorized tilt/rotation/translation stage with liquid coupling tank compatibility |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sonoscan D9650 C-SAM |
| Instrument Type | Digital |
| Compliance | ASTM E1783, ISO/IEC 17025-compatible workflow support, GLP/GMP-ready audit trail (via Sonolytics software) |
| Brand | PAC (Physical Acoustics Corporation) |
|---|---|
| Origin | USA |
| Manufacturer | PAC |
| Model | Tablet-UT |
| Operating System | Windows 7 Embedded (Chinese Localized) |
| Display | 10.4" XGA Touchscreen (1024×768) |
| CPU | Dual-Core x86 Processor |
| Storage | 120 GB SSD |
| Battery Life | >4 hours (Hot-Swappable Li-ion) |
| Channels | 2 independent UT channels |
| Pulse Types | Square, Spike, Tuned Burst |
| Pulse Voltage | 50–400 V |
| Input Impedance | >10 kΩ, 1.00 Ω, 100 Ω |
| Sampling Rate | >5,000 samples/sec |
| Preamp Gain | 12 dB low-noise |
| Bandwidth | 500 kHz – 20 MHz |
| Total Gain Range | 0–82 dB |
| DAC/TCG Range | 0–60 dB |
| Dynamic Range | >70 dB |
| A/D Resolution | 14-bit |
| Motor Axes | 3 |
| Encoder Outputs | 3 quadrature channels |
| Compliance | ASTM E114, E317, E1316 |