Ultraviolet Visible Spectrophotometer
Filter
Showing 1–30 of 232 results
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 3500 |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190 – 1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 0.1 – 5.0 nm (UV-Vis) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 4000 |
| Optical Design | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–900 nm |
| Automation Level | Motorized Wavelength Scanning |
| Spectral Bandwidth | 0.01–5.00 nm (variable) |
| Photometric Range | 0–8.0 Abs |
| Light Sources | Deuterium Lamp (UV), Tungsten-Halogen Lamp (Vis) |
| Maximum Scan Speed | 2000 nm/min |
| Sample Compartment Z-Height | 20 mm |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 5000 |
| Optical Design | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm |
| Automation Level | Motorized Wavelength Scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Photometric Range | ±8.0 Abs |
| Scan Speed | UV-Vis up to 2000 nm/min |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Purge | Dual nitrogen purge (sample chamber & monochromator) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 60 UV-Vis |
| Instrument Architecture | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 1.5 nm (UV-Vis) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 6000i |
| Optical Design | Double-beam |
| Detector | Photomultiplier Tube (PMT) for UV-Vis |
| Wavelength Range | 175–1800 nm (UV-Vis-NIR) |
| Automation Level | Motorized wavelength scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Absorbance Range | Up to 8.0 Abs |
| Scan Speed | UV-Vis: 2000 nm/min |
| NIR | 8000 nm/min |
| Sample Compartment Z-height | 20 mm |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Purge Capability | Dual nitrogen purge (sample chamber & monochromator) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 7000 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Absorbance Range | Up to 10 Abs |
| Max Scan Speed | UV-Vis 2000 nm/min, NIR 8000 nm/min |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Nano-100 |
| Optical Design | Single-beam |
| Detector | 2048-pixel linear CCD array |
| Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | <0.5 nm |
| Spectral Bandwidth | ≤3 nm |
| Stray Light | <0.01% T at 220 nm and 340 nm |
| Sample Volume | 0.5–2.0 µL |
| Pathlength Options | 0.2 mm (high-concentration mode), 1.0 mm (standard mode) |
| Absorbance Accuracy | ±1% at 7.332 A (260 nm) |
| Absorbance Precision | ±0.003 A |
| Absorbance Range (10-mm equivalent) | 0.04–90 A |
| dsDNA Quantification Range | 2–4500 ng/µL |
| Measurement Time | <5 s |
| Light Source | Pulsed xenon flash lamp (rated lifetime ≥1×10⁹ flashes, ~10 years) |
| Power Supply | DC 24 V, 2 A |
| Power Consumption | 20 W (operational), 5 W (standby) |
| Dimensions (W×D×H) | 200×250×166 mm |
| Weight | 2.6 kg |
| Software Compatibility | Windows XP/7/8 |
| Data Export | CSV, PDF, Excel-compatible formats |
| Compliance | CE-marked, RoHS-compliant |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Nano-300 |
| Instrument Architecture | Single-beam |
| Detector | 2048-element linear CCD array |
| Wavelength Range | 200–800 nm |
| Wavelength Automation | Motorized scanning |
| Spectral Bandwidth | 1.5 nm (100 µm slit) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.5 nm |
| Stray Light | <0.05 % at 400 nm |
| OD600 Mode | LED source at 600 ± 8 nm, Absorbance Range: 0–4 A |
| Sample Volume | 0.5–2.0 µL |
| Optical Path Lengths | 0.2 mm (high-concentration), 1.0 mm (standard) |
| Absorbance Accuracy | ±1 % (at 7.332 A, 260 nm) |
| Absorbance Precision | ±0.003 A |
| Absorbance Range (10-mm equivalent) | 0.04–90 A |
| dsDNA Detection Range | 2–4500 ng/µL |
| Measurement Time | <5 s |
| Light Source | Pulsed xenon lamp (OD600 mode: high-stability LED) |
| Data Interface | USB 2.0 |
| Operating System | Custom Android OS (v8.1), 7-inch capacitive touchscreen |
| Power Supply | DC 24 V, 2 A |
| Max Power Consumption | 25 W |
| Standby Power | 5 W |
| Dimensions (W×D×H) | 210 × 268 × 181 mm |
| Weight | 2.8 kg |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Type | Imported Instrument |
| Model | SPECORD 200 PLUS |
| Optical Design | Double-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation | Motorized Wavelength Scanning |
| Spectral Bandwidth | 1.4 nm |
| Wavelength Accuracy | < ±0.1 nm (full range) |
| Wavelength Repeatability | < ±0.01 nm |
| Stray Light | < 0.005% @ 340 nm (NaNO₂) |
| Baseline Stability | ≤ 0.0001 A (RMS) |
| Photometric Range | –5 to +5 A |
| Scan Speed | 12,000 nm/min |
| Light Sources | Deuterium Lamp + Tungsten-Halogen Lamp (automatically switched) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Instrument Type | Double-Beam |
| Model | SPECORD 200 PLUS |
| Optical Design | Holographic Grating Monochromator |
| Detector | Dual-Thermostatted Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Spectral Resolution | ≤1.2 nm (FWHM) |
| Photometric Accuracy | ±0.002 A (at 0.5 A, 1.0 A) |
| Stray Light | <0.0005% T at 220 nm |
| Beam Geometry | True Simultaneous Double-Beam |
| Wavelength Calibration | Pre-aligned Holmium Oxide Filter |
| Compliance | USP <857>, Ph. Eur. 2.2.25, FDA 21 CFR Part 11 (Audit Trail, Electronic Signatures, User Access Control) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Type | Imported Instrument |
| Model | SPECORD 210 PLUS |
| Optical Design | Double-Beam |
| Detector | Peltier-Cooled CCD Array |
| Wavelength Range | 185–1100 nm |
| Spectral Bandwidth | 0.2, 0.5, 1, 2, and 4 nm (5-step adjustable) |
| Wavelength Accuracy | < ±0.1 nm (entire range) |
| Stray Light | < 0.005% at 340 nm (NaNO₂) |
| Photometric Range | –5 to +5 A |
| Baseline Stability | ≤ 0.0001 A (RMS) |
| Long-Term Drift | ≤ 0.0005 A/h |
| Scan Speed | Up to 12,000 nm/min |
| Wavelength Reproducibility | < ±0.01 nm |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Instrument Type | Double-beam |
| Detector | CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | < ±0.1 nm (full range) |
| Wavelength Repeatability | ≤ 0.02 nm |
| Spectral Bandwidth | 0.2, 0.5, 1, 2, and 4 nm (motorized selection) |
| Stray Light | < 0.0002% at 340 nm (NaNO₂) |
| Scan Speed | up to 12,000 nm/min |
| Automatic Wavelength Calibration | 内置 Ho-glass reference filter |
| Light Sources | Deuterium lamp (190–350 nm) and tungsten-halogen lamp (350–1100 nm) |
| Software | SCIENCE™ v3.x with GLP-compliant audit trail, method library, and instrument self-check (SCS) |
| Brand | ANPRO |
|---|---|
| Model | APN-II |
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Wavelength Range | 185–950 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ≤±0.05 nm |
| Detector | CCD Array |
| Optical System | Dual-Wavelength Scanning with Hybrid Diffraction Grating |
| Automation Level | Fully Automatic Wavelength Selection & Sample Handling |
| Sample Throughput | Up to 12 Cuvettes (11 Simultaneous Samples + Reference) |
| Display | 10.1-inch Capacitive Touch LCD with VGA/HDMI Output |
| Computing Platform | Embedded Industrial PC (Quad-Core CPU, 4 GB RAM, Windows OS) |
| Data Storage | 500 GB SSD |
| Connectivity | Dual USB 2.0, RS232, Ethernet, Wi-Fi, VGA, Audio Out |
| Compliance | Designed for GLP-compliant food safety laboratories |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | A360 |
| Price Range | USD 4,200 – 7,000 |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | ≤0.03% T @ 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | A380 |
| Price Range | USD 4,200–7,000 (FOB Shanghai) |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | ≤0.03% T @ 220 nm & 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | A390 |
| Price Range | USD 4,200–7,000 (FOB Shanghai) |
| Optical Design | Single-Beam with Dual-Beam Ratio Monitoring |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5, 1.0, 2.0, 4.0, 5.0 nm |
| Stray Light | ≤0.03% T at 360 nm |
| Display | 6.5K-color TFT LCD (800 × 480) |
| Data Storage | 240 calibration curves (240 data points each) onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.1 host port for firmware update |
| Software | AOE Basic Spectroscopy Suite (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001:2015, CE (2014/30/EU & 2011/65/EU), CMC License (PRC Metrology Certification), RoHS Directive 2011/65/EU |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | A560 |
| Optical System | Dual-beam ratio-monitoring |
| Detector Type | Silicon photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.02% T at 360 nm |
| Wavelength Scanning | Automatic |
| Display | 800 × 480 pixel, 65K-color TFT LCD |
| Data Storage | 240 curves (240 data points each) onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.0 for PC connectivity |
| Software | AOE Basic Spectroscopy Software (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | A580 |
| Optical System | Dual-beam ratio-monitoring |
| Detector Type | Silicon photodiode |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.0 nm |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | ≤0.02% T @ 360 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Display | 800 × 480 pixel, 65K-color TFT LCD |
| Data Storage | 240 curves (240 data points each) onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.0 for PC connectivity |
| Software | AOE Basic Spectroscopy Software (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | A590 |
| Optical System | Dual-Beam Ratio-Monitoring |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm |
| Stray Light | ≤0.02% T @ 360 nm |
| Display | 800 × 480 TFT color LCD (65K colors) |
| Data Storage | 240 curves × 240 data points onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.0 for PC connectivity |
| Software | AOE Basic Spectroscopy Suite (certified under PRC Software Copyright Registration) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | ND300 |
| Optical Design | Single-Beam |
| Detector | 2048-Pixel Linear CCD Array |
| Wavelength Range | 185–910 nm |
| Spectral Bandwidth | 1.8 nm (FWHM at Hg 253.7 nm) |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.1% (at 220 nm & 360 nm) |
| Minimum Sample Volume | 0.5 µL |
| dsDNA Detection Range | 2–15,000 ng/µL |
| Absorbance Accuracy | ±0.002 Abs (1 mm pathlength) |
| Measurement Time | <0.5 s |
| Connectivity | USB 2.0, Wi-Fi, USB Flash Drive Firmware Update |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ND500 |
| Price Range | USD 9,500 – 13,600 (FOB Shanghai) |
| Optical Design | Single-Beam |
| Detector | 2048-Pixel Linear CCD Array |
| Wavelength Range | 185–910 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.1% T at 220 nm and 340 nm |
| Photometric Accuracy | ±0.002 Abs (at 1 mm pathlength) |
| Minimum Sample Volume | 0.5 µL |
| dsDNA Detection Range | 2–15,000 ng/µL |
| Scan Speed | <0.5 s per full spectrum |
| Spectral Resolution | ≤1.8 nm FWHM (measured at Hg 253.7 nm line) |
| Light Source | Pulsed Xenon Lamp |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n |
| Software Update | USB Flash Drive–Based Firmware Upgrade (Lifetime Free) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T1 |
| Instrument Architecture | Single-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 200–1020 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.1% T (at 220 nm and 360 nm) |
| Absorbance Noise | ±0.001 Abs |
| Display | 7-inch TFT LCD Touchscreen (480 × 272 pixels) |
| Data Export | USB flash drive interface |
| Software Features | Audit Trail, GMP/GLP-compliant data logging, lifetime free firmware & software updates |
| Sample Holder Compatibility | Adjustable cuvette holder for 1–5 cm pathlength cells |
| Optical System | Holographic grating (1200 lines/mm) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T1v |
| Optical System | Single-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 325–1020 nm |
| Wavelength Scanning Mode | Motorized Automatic Wavelength Selection |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.1%T at 360 nm |
| Noise Level | ±0.001 Abs |
| Display | 7-inch 480×272 TFT True-color Touchscreen |
| Data Output | USB flash drive export |
| Software Features | Audit Trail, GMP/GLP-compliant data logging |
| Supported Cuvette Pathlengths | 1–5 cm |
| Compliance | Meets pharmacopoeial requirements (ChP, USP <857>, EP 2.2.25) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T2 |
| Price Range | USD 1,400–2,800 |
| Optical Configuration | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 195–1020 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | ±3.8 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.1%T (at 220 nm and 360 nm) |
| Noise Level | ±0.001 Abs |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T2v |
| Price Range | USD 700–1,400 |
| Optical Design | Single-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1020 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | ±3.8 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.1%T (at 220 nm and 360 nm) |
| Absorbance Noise | ±0.001 Abs (at 500 nm, 0 Abs) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | T5 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Automatic |
| Spectral Bandwidth | 4.0 nm (±3.8 nm) |
| Wavelength Accuracy | ±0.4 nm (±0.3 nm at 546.1 nm) |
| Stray Light | ≤0.04% T (at 220 nm and 360 nm) |
| Wavelength Repeatability | ≤0.2 nm |
| Photometric Noise | ±0.0005 Abs (0–0.5 Abs), ±0.0004 Abs (0.5–1.0 Abs) |
| Display | 7-inch TFT LCD Touchscreen (1024 × 800 resolution) |
| Data Export | USB flash drive interface |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Sample Handling | Standard 6-position automatic cuvette changer (1–5 cm pathlength support) |
| Software Compliance | Audit trail enabled, 21 CFR Part 11–ready configuration options |
| Maintenance | Lifetime free firmware and software updates |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | T6 |
| Price Range | USD 2,800–4,300 (FOB Shanghai) |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm (±1.6 nm) |
| Wavelength Accuracy | ±0.4 nm (±0.3 nm at 546.1 nm) |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.04% T (at 220 nm and 360 nm) |
| Absorbance Noise | ±0.0005 Abs (0–0.5 Abs), ±0.0004 Abs (0.5–1.0 Abs) |
| Display | 7-inch TFT LCD Touchscreen (1024 × 800 resolution) |
| Data Interface | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Sample Holder | Integrated 6-position Automatic Cuvette Changer (supporting 1–5 cm pathlength cells) |
| Software Compliance | Audit Trail Enabled, 21 CFR Part 11 Ready (User Authentication, Electronic Signature Support, Immutable Log History) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | U110Pro |
| Price Range | USD 700–1,400 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 200–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scan |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.5 nm |
| Stray Light | ≤0.1% T at 220 nm and 340 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Baseline Stability | ±0.001 Abs/h at 500 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | U120Pro |
| Price Range | USD 1,400–2,800 |
| Optical Design | Single-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 195–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.0 nm |
| Stray Light | ≤0.1% T at 220 nm and 340 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Baseline Stability | ±0.001 Abs/h at 500 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | UV-1000 |
| Optical System | Single-beam with dual-beam ratio monitoring |
| Detector Type | Photocell |
| Wavelength Range | 200–1020 nm |
| Wavelength Accuracy | ±1.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 4.0 nm |
| Stray Light | ≤0.1% T @ 360 nm |
| Display | 128 × 64 dot-matrix LCD |
| Data Output | USB port (U-disk export), RS-232 serial printer interface |
| Software | AOE Basic Spectroscopy Software (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001, CE, CMC, RoHS |