Ultraviolet Visible Spectrophotometer
Filter
Showing 181–210 of 232 results
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2600A |
| Optical System | Single-beam with 1200 lines/mm holographic grating |
| Wavelength Range | 190–1000 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.8 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.05% T |
| Detector Type | Silicon Photocell |
| Wavelength Scanning Mode | Motorized Automatic |
| Display | 320 × 240 Graphic LCD |
| Data Interface | USB |
| Dimensions (W×D×H) | 545 × 245 × 260 mm |
| Weight | 20 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2800A |
| Optical System | Single-beam with 1200 lines/mm holographic grating |
| Wavelength Range | 190–1000 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.05% T |
| Detector Type | Photocell |
| Wavelength Scanning Mode | Motorized automatic wavelength drive |
| Display | 320 × 240 graphic LCD |
| Data Interface | USB port for direct data export to USB flash drive |
| Dimensions (W × D × H) | 545 × 245 × 260 mm |
| Weight | 20 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2802 |
| Optical System | Single-beam with 1200 lines/mm holographic grating |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Linearity | ±0.002 A |
| Stability | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | 320 × 240 graphic LCD |
| Data Interface | USB port |
| Dimensions (W × D × H) | 625 × 405 × 280 mm |
| Weight | 22 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2802S |
| Optical System | Single-beam with 1200 lines/mm holographic grating |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 nm (selectable) |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Linearity | ±0.002 A |
| Stability | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | 320 × 240 graphical LCD |
| Data Interface | USB port |
| Dimensions (W×D×H) | 625 × 405 × 280 mm |
| Weight | 20 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-3802 |
| Optical System | Pseudo-Double-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Stability | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | 320 × 240 graphical LCD |
| Data Interface | USB port |
| Dimensions (W×D×H) | 625 × 405 × 280 mm |
| Weight | 22 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-3802S |
| Optical System | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 nm (selectable) |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Drift | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | 320 × 240 graphical LCD |
| Data Interface | USB port |
| Dimensions (W × D × H) | 625 × 405 × 280 mm |
| Weight | 24 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-4800 |
| Optical System | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.2 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.1% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Stability | ±0.002 A/h (at 500 nm, after warm-up) |
| Baseline Linearity | ±0.001 A |
| Display | 320 × 240 graphical LCD |
| Data Interface | USB port |
| Dimensions (W × D × H) | 545 × 245 × 260 mm |
| Weight | 22 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-4802 |
| Optical System | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Drift | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | 320 × 240 graphic LCD |
| Data Interface | USB port |
| Dimensions (W × D × H) | 625 × 405 × 280 mm |
| Weight | 23 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-4802S-4 Slit Width |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm at 656.1 nm / ±0.3 nm across range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5, 1, 2, and 4 nm (selectable) |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Stability | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | 320 × 240 graphical LCD |
| Interface | USB port for data export and software communication |
| Dimensions (W × D × H) | 625 × 405 × 280 mm |
| Weight | 24 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Single-Beam UV-Visible Spectrophotometer |
| Wavelength Range | 325–1000 nm |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ±1.0 nm |
| Stray Light | ≤0.2% T (at 340 nm) |
| Photometric Range | 0–125% T, –0.097–1.999 A, 0–1999 C/F |
| Photometric Accuracy | ±0.5% T |
| Baseline Stability | ±0.002 A/h at 500 nm |
| Detector | Photodiode Array |
| Wavelength Setting | Motorized Auto-Scan |
| Display | 4-digit LED, resolution 1 nm |
| Data Interface | RS-232C serial port |
| Printer Port | Parallel interface |
| Dimensions (W×D×H) | 470 × 400 × 140 mm |
| Weight | 10 kg |
| Brand | UNICO |
|---|---|
| Origin | Shanghai, China |
| Model | V-1850 |
| Optical System | Single-beam |
| Detector | Photodiode Array |
| Wavelength Range | 315–1100 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.05% T (at 220 nm & 340 nm) |
| Display Resolution | 0.1 nm |
| Interface | USB, Bluetooth, Touchscreen (7″ TFT, 800×480) |
| Power Input | 80–250 V AC, 50/60 Hz |
| Dimensions | 485 × 365 × 200 mm |
| Weight | 11 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | V-1860 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 315–1050 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.05% T |
| Wavelength Display Resolution | 0.1 nm |
| Auto-wavelength Setting | Yes |
| Data Storage | USB flash drive support |
| Connectivity | Bluetooth printing, mobile app (iOS/Android), email/QQ/WeChat sharing |
| Touch Interface | 7-inch capacitive touchscreen |
| Scan Speed | Up to 3000 nm/min (high mode) |
| Scan Interval | Adjustable from 0.1 to 5 nm |
| Kinetic Sampling Interval | Minimum 0.5 s |
| Max Duration | 9 h |
| Calibration Modes | Auto-zero (0% T) and auto-reference (100% T) |
| Curve Fitting | Linear (zero/non-zero intercept), quadratic, cubic regression |
| Data Capacity | 100 test records per method |
| Grating | 1200 lines/mm holographic diffraction grating |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | V1800 |
| Optical System | Single-beam with 1200 lines/mm holographic grating |
| Wavelength Range | 325–1000 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.8 nm |
| Wavelength Repeatability | ±0.2 nm |
| Stray Light | ≤0.2% T at 360 nm |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.005 Abs (0.5–1.0 Abs), ±0.3% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Linearity | ±0.002 A |
| Stability | ±0.002 A/h at 500 nm (after warm-up) |
| Display | 126 × 64 dot-matrix LCD |
| Data Interface | USB and Centronics |
| Dimensions (W×D×H) | 485 × 365 × 220 mm |
| Weight | 13.5 kg |
| Brand | UniCov |
|---|---|
| Origin | Shanghai, China |
| Model | V1600 |
| Optical System | Single-beam |
| Wavelength Range | 325–1000 nm |
| Spectral Bandwidth | 2 nm / 4 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 1 nm |
| Stray Light | ≤0.4% T (at 360 nm) |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.005 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Linearity | ±0.002 A |
| Drift | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | Large LCD with 1 nm wavelength resolution |
| Dimensions | 360 × 280 × 180 mm |
| Weight | Not specified |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | photoLab 7600 VIS |
| Optical Design | Pseudo-double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automatic Wavelength Selection | Yes |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.003E (for E < 0.600), ±0.5% (for 0.600 < E < 2.00) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | i3 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 360–900 nm (Visible) |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Display | 7-inch TFT touchscreen (1024 × 768) |
| Photometric Range | 0–200% T, –0.3 to 3.0 A |
| Wavelength Setting | Automatic |
| Light Source | Dual-lamp system with long-life halogen and deuterium lamps (optional UV extension) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, RS-232 |
| Software Functions | Wavelength scanning, kinetic analysis, quantitative analysis, nucleic acid/protein assay, spectral overlay, derivative/integration processing |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | i4 |
| Instrument Architecture | Single-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Spectral Bandwidth | 4 nm |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Photometric Range | 0–200% Transmittance, –0.3 to 3.0 Absorbance |
| Display | 7-inch capacitive touchscreen (1024 × 768 resolution) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, RS-232 |
| Software Functions | Wavelength Scanning, Kinetic Measurement, Quantitative Analysis, Nucleic Acid & Protein A260/A280 Assay, Multi-Wavelength Overlay, First-Order Derivative, Integration |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | i5 |
| Quotation | Upon Request |
| Optical Design | Single-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 360–900 nm (Visible Region) |
| Wavelength Scanning | Automatic |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.5%T at 420 nm (NaNO₂ reference) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | i6 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Photometric Range | 0–200% T, –0.3 to 3.0 A |
| Display | 7-inch capacitive touchscreen (1024 × 768 px) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, RS-232 |
| Auto Functions | Automatic wavelength calibration, automatic lamp switching (D₂/WS), T/A mode toggle, real-time baseline correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L-3700 |
| Optical System | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI solution) |
| Display | 8-inch capacitive touchscreen (1024 × 800 resolution) |
| Internal Storage | 5000 absorbance measurements or 500 calibration curves |
| Data Export Formats | *.csv, *.qua, *.txt, *.bmp |
| Compliance | GLP/GMP-aligned software architecture with user management, audit trail, and electronic signature support |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | L-3700S |
| Instrument Architecture | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 1 nm (standard), adjustable to 0.5/2.0/4.0/5.0 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03% at 220 nm (using NaI solution) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L-3800 |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI) |
| Display | 8-inch capacitive touchscreen (1024 × 800 resolution) |
| Light Source | Imported deuterium and tungsten lamps |
| Internal Data Storage | Up to 5000 absorbance measurements or 500 calibration curves |
| Scan Speed | Full-spectrum scan in <1.5 s |
| Auto-functions | Automatic wavelength calibration, source switching, zero adjustment, and baseline correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | L-3800S |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm (fixed), with optional 0.5/2.0/4.0/5.0 nm selectable via software |
| Stray Light | ≤0.03% T at 220 nm (NaI) |
| Absorbance Range | –4 to +4 Abs |
| Display | 8-inch capacitive touchscreen (1024 × 800 resolution) |
| Internal Storage | 5000 absorbance measurements or 500 calibration curves |
| Data Export Formats | CSV, QUA, TXT, BMP |
| Compliance | GLP/GMP-ready software architecture with user management, audit trail, and electronic record retention |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | L1 |
| Instrument Architecture | Single-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm (UV-Vis) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Spectral Bandwidth | 2 nm (standard), 4 nm (default per spec sheet) |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂ method) |
| Display | 7-inch color TFT-LCD touchscreen (1024 × 768 resolution) |
| Data Storage | 2000 spectra or absorbance readings |
| Connectivity | USB 2.0 port, integrated Wi-Fi module, Bluetooth 5.0 module |
| Software Compatibility | Yokelab PC software (optional), cloud sync via YOKE@Cloud Data app |
| Data Export | CSV/Excel-compatible format via USB flash drive |
| Compliance | Designed to support GLP-compliant workflows with timestamped audit trails, user-access logging, and exportable metadata |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L2 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Spectral Bandwidth | 2 nm (standard), 4 nm (optional) |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Display | 7-inch color TFT-LCD (1024 × 768) with capacitive touch |
| Data Storage | 2000 spectra + 96 calibration curves |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Software Interface | Yokelab PC software (optional), YOKE@Cloud Data mobile app (QR-code enabled) |
| Output Format | CSV/Excel-compatible export via USB drive |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L3 |
| Optical Design | Single-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 320–1100 nm |
| Spectral Bandwidth | 4 nm (2 nm optional) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤±0.5 nm |
| Stray Light | ≤0.1% T at 420 nm (NaNO₂) |
| Photometric Range | 0–200% T, –3 to +3 A |
| Photometric Accuracy | ±0.5% T / ±0.004 A (0–0.5 A), ±0.008 A (0.5–1 A) |
| Photometric Repeatability | ±0.5% T / ±0.004 A (0–0.5 A), ±0.008 A (0.5–1 A) |
| Baseline Stability | ±0.002 A (500 nm, 3 min) |
| Noise Level | ≤0.15% T |
| Grating | Holographic Blazed Grating, 1200 lines/mm |
| Display | 7-inch TFT-LCD Touchscreen (1024 × 768) |
| Connectivity | USB 2.0, Wi-Fi (standard), Bluetooth 4.2 (standard) |
| Data Storage | 2000 spectra + 96 calibration curves |
| Software | YokeLab PC software (optional), YOKE@Cloud IoT platform (standard) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L4 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.5 nm |
| Spectral Bandwidth | 4 nm (2 nm optional) |
| Stray Light | ≤0.1% T |
| Display | 7-inch color TFT LCD (1024 × 768) |
| Data Storage | 2000 spectra + 96 calibration curves |
| Scan Speed | up to 3000 nm/min |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Software Compatibility | Yokelab PC Suite (optional), cloud-integrated via YOKE@Cloud Data app |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | L5 |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm (UV-Vis) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Automation Level | Automatic Wavelength Selection & Lamp Switching |
| Data Storage Capacity | 500 spectra, 30 calibration curves |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Software Compatibility | Yokelab PC Suite (optional), Excel-compatible CSV export |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L6 |
| Optical Design | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% at 220 nm (NaI) |
| Automation Level | Automatic Wavelength Scanning & Lamp Switching |
| Connectivity | USB 2.0, Wi-Fi Module, Bluetooth 4.2 |
| Data Storage Capacity | 500 spectra, 30 calibration curves |
| Software Compatibility | Yokelab PC Suite (optional), Excel-compatible CSV export |