Viscometers
Filter
Showing 1–30 of 120 results
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | SV-10 |
| Instrument Type | Oscillatory Viscometer |
| Mounting Style | Benchtop Fixed |
| Operating Environment | High-Temperature Capable |
| Viscosity Range | 0.3 mPa·s to 10 Pa·s |
| Temperature Range | 0–160 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 1 °C/min |
| Vibration Frequency | 30 Hz |
| Amplitude | 1 mm |
| Repeatability | ±1% of reading (std. dev.) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | SV10 / SV-100 |
| Measurement Principle | Sinusoidal fork vibration method (30 Hz) |
| Viscosity Range | SV10: 0.3–10,000 mPa·s |
| SV-100 | 1,000–100,000 mPa·s |
| Repeatability | ±1% of reading (full scale, SD, 20–30 °C, no condensation) |
| Minimum Sample Volume | 35 mL |
| Display | Fluorescent LCD (large-character, high-contrast) |
| Interface | RS-232C standard |
| Temperature Control Option | Compatible with external circulating water bath |
| Software | WinCT-Viscosity (RsVisco) included |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Construction | Titanium-coated vibrating fork sensor (corrosion-resistant, easy-clean) |
| Form Factor | Benchtop fixed-unit system |
| Operating Environment | Ambient temperature (15–35 °C), non-condensing |
| Brand | Anton Paar TriTec (formerly CSM, Switzerland) |
|---|---|
| Origin | Switzerland |
| Model | Lovis 2000 M/ME |
| Viscosity Range | 0.3–10,000 mPa·s |
| Repeatability | < 0.1 % |
| Reproducibility | < 0.5 % |
| Ball Fall Time Range | 0–250 s (up to 1000 s with extended mode) |
| Time Resolution | 0.001 s |
| Temperature Control Range | +5 to +100 °C |
| Temperature Stability | ±0.005 °C |
| Temperature Accuracy | < ±0.02 °C |
| Sample Volume | 0.1–0.8 mL |
| Power Supply | 100–240 V, 50–60 Hz, 190 VA |
| Dimensions (L×W×H) | 482 × 420 × 231 mm |
| Weight | 17 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Lovis 2000 M/ME |
| Instrument Type | Falling Ball Viscometer |
| Mounting | Benchtop (Fixed) |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.3 mPa·s to 10,000 mPa·s |
| Temperature Range | +5 °C to 100 °C |
| Sample Volume | 100 µL (minimum) |
| Tilt Angle Range | 15° to 80° (1° increments) |
| Shear Rate Range | 0.5 s⁻¹ to 1,000 s⁻¹ |
| Viscosity Repeatability | ≤ 0.1 % (std. dev.) |
| Viscosity Accuracy | ≤ 0.5 % |
| Temperature Repeatability | ±0.005 °C |
| Temperature Accuracy | ±0.02 °C |
| Timing Resolution | 0.001 s |
| Timing Accuracy | ±0.05 % |
| Measurement Time | As low as 30 s (typical: 3 min) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Lovis 2001 |
| Instrument Type | Fixed-Position Falling-Ball Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.2 to 10,000 mPa·s |
| Temperature Range | 5 °C to 100 °C (41 °F to 212 °F) |
| Temperature Resolution | 0.005 °C |
| Temperature Accuracy | ±0.02 °C |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SVM Series |
| Instrument Category | Kinematic Viscometer |
| Instrument Form Factor | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.2 to 30,000 mm²/s |
| Temperature Control Range | 15 °C to 100 °C (standard) |
| Compliance | ASTM D7042, ASTM D445 (with bias correction), ISO 23581, EN 16896, ASTM D4052, ISO 12185, ASTM D2386, ASTM D2500, ASTM D396, D975, D1655, D3699, D6158, D6823, D7467 |
| Patents | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1), AT516302 (B1), CN105628550 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | SVM™ 2001 / SVM™ 3001 / SVM™ 4001 |
| Viscosity Range | 0.2 to 30,000 mm²/s |
| Temperature Range | +15 °C to +100 °C (SVM™ 2001 & 4001) |
| Density Range | 0.6 to 3.0 g/cm³ |
| Sample Volume | 1.5–6 mL |
| Compliance | ASTM D7042, ISO 12185, EN 16896, ASTM D4052, ISO 2909, ASTM D2270, ISO 91, ASTM D1250, ASTM D2161 |
| Cooling | Integrated Peltier (down to –20 °C) |
| Power | AC 100–240 V, 50–60 Hz, max. 250 VA |
| Dimensions (W × D × H) | 33 × 51 × 23.1 cm |
| Net Weight | 15.9–17.8 kg |
| Brand | ATAC |
|---|---|
| Origin | United Kingdom |
| Model | REL0230 |
| Temperature Range | Ambient to 230 °C (no cooling) |
| Sample Volume | 0.2 mL |
| Compliance | BS EN ISO 2884-1:2006 |
| Temperature Accuracy | ±0.1 °C |
| Speed Range | 5–900 rpm (integer steps) |
| Viscosity Accuracy | ±2% of full scale (calibrated with standard oils) |
| Display | 4.3″ color LCD |
| Data Interface | USB |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W |
| Dimensions (H×W×D) | 510 × 302 × 302 mm |
| Weight | 13.0 kg |
| Brand | ATAC |
|---|---|
| Origin | United Kingdom |
| Model | REL0100 |
| Instrument Type | Cone-Plate Rotational Viscometer |
| Temperature Range | 10 °C to 100 °C |
| Sample Volume | 0.2 mL |
| Compliance | BS EN ISO 2884-1:2006 |
| Full-Scale Accuracy | ±2% (calibrated with standard oils) |
| Speed Range | 5–900 rpm (integer steps) |
| Low-Speed Mode | 5–90 rpm (0.1 rpm increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Display | 4.3-inch color LCD |
| Data Interface | USB |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W |
| Dimensions (H×W×D) | 510 × 302 × 302 mm |
| Weight | 13.5 kg |
| Brand | ATAC |
|---|---|
| Origin | United Kingdom |
| Model | REL0150 |
| Instrument Type | Oscillatory Cone-Plate Viscometer |
| Portability | Portable |
| Operating Environment | Ambient Temperature |
| Display | 4.3-inch Color LCD |
| Speed Range | 5–900 rpm (Low-Speed Mode: 5–90 rpm, Adjustable in 0.1-rpm Increments) |
| Accuracy | ±1% (Calibrated with Standard Reference Oils) |
| Compliance | BS EN ISO 2884-1:2006 |
| Cone Options | Six Interchangeable Cones |
| Calibration | Onboard Auto-Calibration for Multiple Cone Geometries |
| Connectivity | PC Interface via USB/RS-232 for Data Acquisition and Analysis |
| Software Features | Real-Time Shear Rate vs. Time Plotting, Multi-Format Data Export (CSV, TXT, XLS), Temperature-Compensated Viscosity Readout, Unit Selection (mPa·s, cP, Pa·s) |
| Brand | ATAC |
|---|---|
| Origin | United Kingdom |
| Model | REL0250 |
| Instrument Type | High-Temperature Portable Cone-Plate Viscometer |
| Speed Range | 5–900 rpm (Low-Speed Mode: 5–90 rpm, Adjustable in 0.1-rpm Increments) |
| Display | 4.3-inch Color LCD |
| Calibration | Onboard Auto-Calibration for Multiple Cone-Plate Geometries |
| Cone Options | Six Standard Cone-Plate Sets Available |
| Accuracy | ±1% (Verified with NIST-Traceable Standard Oils) |
| Compliance | BS EN ISO 2884-1:2006 |
| Temperature Capability | High-Temperature Operation (Compatible with External Heated Sample Chambers or Integrated Thermal Control Systems) |
| Connectivity | RS-232/USB PC Interface with Dedicated Data Acquisition Software |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | 6811 |
| Instrument Type | Benchtop Viscometer |
| Viscosity Range | 1–2,000 mPa·s (with ULA adapter) |
| Torque Range | 0.0–100.0% (recommended: 10.0–100.0%) |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Rotational Speed | 0.5–250 rpm (20 discrete steps) |
| Viscosity Resolution | 0.01 mPa·s (≤100 mPa·s), 0.1 mPa·s (100–10,000 mPa·s), 1 mPa·s (>10,000 mPa·s) |
| Viscosity Accuracy | ±1% of full scale |
| Power Supply | 4 × AA alkaline batteries (DC 6 V) or AC adapter (100–240 V AC) |
| Battery Life | ~7 hours (continuous operation at 60 rpm) |
| Data Interface | USB to PC |
| Operating Environment | 10–40 °C ambient, 10–40 °C sample temperature |
| Compliance | Designed for ISO 2555 and ASTM D2196-compliant viscosity measurement workflows |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | VISCO B(L) |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 12–60,000,000 mPa·s |
| Temperature Range | 5.0–90.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Torque Range | 10.0–100.0% (recommended) |
| Speed Range | 0.01–250 rpm (28 selectable speeds) |
| Viscosity Accuracy | ±1% |
| Standard Spindles | L1, L2, L3, L4 |
| Power Supply | 4× AA alkaline batteries or AC adapter |
| Interface | USB to PC |
| Dimensions (main unit) | 178 × 86 × 194 mm |
| Weight (main unit) | 1.2 kg |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Bostwick Consistometer |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | CAP1000+, CAP2000+ |
| Instrument Type | Rotational Viscometer (Cone-Plate Geometry) |
| Torque Range | High Torque (181,000 dyne·cm) / Low Torque (7,970 dyne·cm) |
| Shear Rate Range | 0.2–15,000 s⁻¹ (dependent on cone spindle and speed selection) |
| Sample Volume | 24–1700 µL |
| Temperature Control | L-Series (5–75°C), H-Series (50–235°C) |
| Display | 4-line LCD |
| Compliance | ASTM D4287, ISO 2884, BS 3900, GB/T 9751 |
| Software | CapCalc32 (PC-based control, data acquisition, rheological modeling) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | CAP2000+ |
| Shear Rate Range | up to 12,000 s⁻¹ |
| Viscosity Range | 0.025–10 cP (with 6 spindles) |
| Sample Volume | < 1 mL |
| Temperature Control | Dual integrated systems |
| Display | Digital LCD |
| Data Acquisition | PC-controlled via proprietary software |
| Compliance | ASTM D4287, ISO 2884, BS 3900 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model Series | CAP |
| Instrument Type | Rotational Viscometer |
| Mounting Style | Benchtop (Fixed) |
| Operating Environment | High-Temperature Capable |
| Viscosity Range | 20 – 1,500,000 mPa·s |
| Temperature Range | 5–235 °C |
| Torque Options | High Torque (ICI Standard): 181,000 dyne·cm |
| Low Torque | 7,970 dyne·cm |
| Speed Range | 5–1000 rpm (995 programmable increments) |
| Sample Volume | < 1 mL |
| Temperature Control | Peltier-based (L-Series: 5–75 °C |
| H-Series | 50–235 °C) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | Dial Viscometer |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–8,000,000 mPa·s |
| Torque Accuracy | ±1% of Full Scale |
| Repeatability | ±0.2% of Full Scale |
| Speed Control | Manual Stepwise (0.3–100 rpm, model-dependent) |
| Calibration Traceability | NIST-Traceable Standard Fluids |
| Power Supply | Universal AC Input (100–240 VAC, 50/60 Hz) |
| Warranty | 2-Year Limited |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DV-II+ Pro |
| Pricing | Available Upon Request |
| Torque | 673.7 dyn·cm |
| Speed Range | 0.01–200 rpm (54 programmable speeds) |
| Spindles | 4 standard spindles included |
| Viscosity Range | 15–2,000,000 cP |
| Display | Digital LCD showing viscosity (cP), % torque, temperature (°C), rotational speed (rpm), and spindle identification |
| Control Interface | Microprocessor-based touchpad control with RS-232 interface for PC connectivity |
| Temperature Sensing | Compatible with RTD temperature probes (e.g., PT100) for real-time thermal monitoring |
| Data Acquisition | Supports DV-Gather™ software for multi-curve overlay (up to 5 simultaneous datasets), synchronized temperature logging, and time-stamped data export |
| Output | RS-232 port for connection to chart recorders or thermal printers for scheduled hard-copy reporting |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Instrument Type | Rotational Viscometer |
| Model | DV-II+Pro EXTRA |
| Bearing System | Precision Ball-Bearing Suspension (excludes LV models) |
| Speed Range | 0.1–200 rpm (54 programmable speeds) |
| Viscosity Accuracy | ±1.0% of reading |
| Repeatability | ±0.2% |
| Displayed Parameters | Viscosity (cP or mPa·s), Temperature (°C or °F), Shear Rate/Shear Stress, % Torque, Rotational Speed, Rotor ID, Timed Stop Countdown |
| Included Accessories | EZ-Lock Quick-Connect Rotor System, Q-Drive Vertical Positioning Stand, Integrated Temperature Probe, RheoCalc Software, DV Loader Software, Standard Rotor Set (4 for LV |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV1 |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Speed Control | 18 programmable RPM settings (0.3–100 rpm) |
| Display | Large-font, multi-parameter digital LCD |
| Languages | English, Chinese, French, German, Spanish, Portuguese, Russian |
| Interface | USB (compatible with optional Wingather SQ software) |
| Temperature Measurement | Optional RTD probe (DVP-94Y, requires specification at time of order) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DV2Plus |
| Instrument Type | Rotational Viscometer |
| Mounting Style | Benchtop (Fixed) |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–320 × 10⁶ mPa·s |
| Temperature Range | 0–300 °C |
| Compliance | ISO/IEC 17025 Calibration Available, NIST-Traceable Standards, FDA 21 CFR Part 11 Readiness (via optional software module) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2Plus |
| Viscosity Range (cP) | LV: 1–6M |
| RV | 100–40M |
| HA | 200–80M |
| HB | 800–320M |
| Speed Range | 0.1–200 rpm (740 programmable steps) |
| Accuracy | ±1.0% |
| Repeatability | ±0.2% |
| Display | 7″ color PCAP touchscreen (800 × 480 resolution) |
| Compliance | Optional 21 CFR Part 11 via DV360™ software |
| Connectivity | Bluetooth, USB-A, USB-B |
| Included Spindles | 4× LV, 6× RV/HA/HB (model-dependent) |
| Built-in Features | Gel time measurement, oscillatory test mode, digital leveling, viscosity test wizard, step-programmable method execution |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DV2T |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1 – 320 × 10⁶ mPa·s |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2T |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–6,000,000 cP (mPa·s) |
| Temperature Accuracy | ±1.0% of full-scale reading |
| Speed Control | 200 programmable RPM settings (0.1–200 rpm) |
| Display | 5-inch full-color touchscreen |
| Compliance | ASTM D2196, ISO 2555, USP <911>, GLP/GMP-ready data logging |
| Interface | USB PC connectivity with optional PG Flash and Rheocalc T software support |
| Standard Spindles | LV (4), RV/HA/HB (6) depending on configuration |
| Operating Environment | Ambient temperature |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2T |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1 to 320 × 10⁶ mPa·s (cP) |
| Speed Control | 0.01–200 rpm (200 programmable increments) |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Temperature Measurement | Integrated RTD probe (±0.1 °C typical) |
| Display | 5-inch full-color touchscreen |
| Compliance | FDA 21 CFR Part 11 (electronic signatures, user access levels, audit trail) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2T Gel Time Tester |
| Type | Rotational Viscometer with Gel Time Measurement Capability |
| Compliance | ASTM D2471, ISO 3219, USP <911> (Gelation Time) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–320 mPa·s (cP) |
| Display | 5-inch Full-Color TFT Touchscreen |
| Compliance | FDA 21 CFR Part 11 Ready |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Temperature Probe | Integrated RTD sensor (±0.1 °C) |
| Data Interface | USB-B to PC |
| Standard Accessories | LV-1 spindle, leveling bubble vial, PG Flash software |
| Optional Software | RheoCalcT (included with DV2T EXTRA configuration) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2TLV |
| Viscosity Range | 1–200 mPa·s |
| Instrument Type | Benchtop (Not Online) |
| Operating Environment | Ambient Temperature |
| Software | RheoCalc T v3.x |
| Compliance | FDA 21 CFR Part 11 (Electronic Signatures, User Access Control, Audit Trail) |
| Data Storage | Password-Protected Local Database |
| Test Modes | Single-Point, Ramp, Hold, Cycle |
| Mathematical Models | Bingham, Casson, Power Law, Herschel-Bulkley |
| Multi-Sample Comparison | Up to 5 Data Sets |
| Temperature Control | Not Integrated (Requires External Bath or Peltier Accessory) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV3T |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–1.6 × 10⁶ mPa·s (cP) |
| Display | 7-inch full-color touchscreen (multi-language support) |
| Temperature Probe | Built-in RTD sensor |
| Accuracy | ±1.0% of reading |
| Repeatability | ±0.2% |
| Connectivity | USB PC interface (included), optional PC control & automated data acquisition via PG Flash software |
| Compliance | Supports GLP/GMP documentation workflows, audit trail-ready for FDA 21 CFR Part 11–aligned environments (when used with validated software configuration) |