| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DVNext |
| Instrument Type | Rotational Viscometer/Rheometer |
| Viscosity Range | 1–320M mPa·s |
| Display | 7-inch Full-Color Touchscreen |
| Compliance | 21 CFR Part 11, GAMP 5 |
| Temperature Accuracy | ±1% of full scale (with PT-100 probe) |
| Internal Storage | 150 MB |
| Connectivity | USB, LIMS-ready, optional Ethernet/Wi-Fi |
| Control Mode | Standalone or PC-controlled (RheocalcT software) |
| Spindle Coupling | Magnetic coupling system |
| Leveling | Digital auto-leveling |
| Test Modes | Single-step & multi-step programmable protocols |
| Yield Stress & Flow Curve Analysis | Built-in Casson, Bingham, Power Law, Thix Index models |
| Temperature Integration | Compatible with AP/SD series circulators and high-temperature systems |
| Accessories Support | Cone/plate geometry, UL adapter, small-volume adapter, gel time coupler, DIN/ISO adapters, spiral, T-bar, paddle rotors, roller bearing spindles (HA/HB), RV/HA/HB-1 spindles |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVNext |
| Instrument Type | Rotational Viscometer/Rheometer |
| Mounting | Benchtop (Fixed) |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–320 million cP (mPa·s) |
| Temperature Control | External (via AP/SD Series Circulators or High-Temp Systems) |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | 1 °C |
| Speed Range | 0.01–250 RPM (2,600 programmable increments) |
| Compliance | FDA 21 CFR Part 11 (Regulatory-Ready Firmware & Audit Trail) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVNext |
| Viscosity Range (LV) | 0.01–250 cP (mPa·s) |
| Viscosity Range (RV/HA/HB with Optional Spindles) | up to 320M cP |
| Speed Control | 2600 programmable RPM increments (0.01–250 RPM) |
| Display | 7-inch full-color touchscreen |
| Temperature Accuracy | ±1% of full scale (with PT-100 probe) |
| Data Storage | 150 MB internal |
| Compliance | 21 CFR Part 11, GAMP 5 |
| Connectivity | USB, optional LIMS integration |
| Accessories Supported | UL Adapter (1 cP min), Cone & Plate systems, AP/SD temperature baths, RheocalcT software, barcode scanner, gel timer module, DIN adapters, T-spindles, spiral adaptors, small sample adapters |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVNext |
| Viscosity Range | 0.01–250 mPa·s |
| Instrument Type | Benchtop (with portable operational flexibility) |
| Compliance | Fully compliant with FDA 21 CFR Part 11 in standalone mode |
| Connectivity | Ethernet and LIMS integration supported |
| Rotor Mounting | One-hand quick-coupling mechanism |
| Leveling | Integrated electronic auto-leveling system |
| Operating Environment | Ambient temperature (15–30 °C) |
| Application Class | General-purpose rotational viscometry for QC, R&D, and production environments |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DVNext CP |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 0.1 – 7.8 M mPa·s |
| Display | 7-inch Full-Color Touchscreen |
| Compliance | FDA 21 CFR Part 11 & GAMP 5 (Regulatory Edition Only) |
| Onboard Storage | 150 MB with Timestamped Data Files |
| Temperature Control | Integrated Peltier-Based System with Embedded Sample Probe |
| Software | RheocalcT™ (PC-based), Optional LIMS/Barcode Integration |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVNXLVCP |
| Viscosity Range (mPa·s) | 0.1–3,000 |
| Shear Rate Range | 7.5–92,000 s⁻¹ (depending on cone geometry) |
| Sample Volume | 0.5–2.0 mL |
| Speed Range | 0.01–250 rpm (2600 discrete steps) |
| Accuracy | ±1.0% of reading |
| Repeatability | ±0.2% |
| Cone/Plate Gap Adjustment | Motorized touchscreen-controlled |
| Display | 7-inch full-color capacitive touch screen |
| Compliance | FDA 21 CFR Part 11, GAMP 5-ready (configurable at order), GLP/GMP-supportive audit trail |
| Data Storage | 150 MB internal memory |
| Interface | USB host/device, RS-232 (optional) |
| Temperature Control | Integrated Peltier interface for external bath (AP/SD series) or high-temp systems |
| Mathematical Models | Casson, Bingham Plastic, Power Law, Thixotropy Index (TI), Yield Stress estimation |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVPlus |
| Display | 5-inch full-color touchscreen |
| Speed Control | 740 programmable RPM increments (0.1–200 rpm) |
| Viscosity Range | 1 cP to 320,000,000 cP (depending on spindle and speed selection) |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Torque Measurement | 0.1–100% of full-scale torque (mN·m, dyne·cm, %) |
| Temperature Compensation | ±5°C |
| Interface | USB + Bluetooth (DVPlus CONNECT compatible) |
| Optional Accessory | RTD temperature probe (DVP-94Y) |
| Language Support | English, French, German, Portuguese, Spanish, Japanese, Chinese |
| Compliance | Designed for GLP/GMP environments |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DVPLUS |
| Instrument Type | Rotational Viscometer |
| Mounting Style | Benchtop (Fixed) |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1 to 320 × 10⁶ mPa·s |
| Temperature Range | 0–300 °C |
| Display | 5-inch Full-Color Touchscreen |
| Speed Settings | 740 Programmable RPM Steps |
| Accuracy | ±1.0% of Full Scale Reading |
| Repeatability | ±0.2% |
| Torque Measurement Units | % torque, mN·m, dyne·cm |
| Viscosity Units | cP, mPa·s, P, Pa·s |
| Temperature Units | °C, °F, K |
| Temperature Compensation Range | ±5 °C |
| Interface Options | USB 2.0, Bluetooth 4.0 (optional) |
| Optional Temperature Probe | DVP-94Y |
| Timing Functions | Time-to-target torque, time-to-target temperature, test duration control |
| Auto-Range Indication | Full-scale viscosity (FSR) and maximum measurable viscosity for current spindle/speed combination |
| Language Support | English, French, German, Portuguese, Simplified Chinese, Japanese, Spanish |
| Software Compatibility | DVPlus Connect (Windows PC application |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FAST |
| Instrument Type | In-line Viscometer |
| Application Environment | High-Temperature Process |
| Viscosity Range | 0–10, 0–50, 0–100, 0–250, 0–500, 0–1000, 0–1500 cSt |
| Temperature Range | –20°C to 120°C (–4°F to 248°F) |
| Measurement Principle | Torsional Resonance (Vibrational Shear) |
| Repeatability | ±1.0% of reading |
| Wetted Materials | 316L Stainless Steel |
| Sealing Material | Fluoroelastomer (FKM) O-rings (EDPM or Kalrez® optional) |
| Pressure Rating | Vacuum to 200 psig |
| Enclosure | NEMA-4 (IP65), Wall-Mounted Electronics Housing |
| Output | Dual 4–20 mA (Viscosity + Temperature), RS232 & RS485 (Modbus RTU), Optional Hazardous Area Certifications (NEMA 7 / ATEX), Optional 3A Sanitary Compliance |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | KU-2 |
| Operating Temperature | 10–40 °C |
| Rotational Speed | 200 rpm ±0.1 rpm |
| Compliance | ASTM D562 |
| Output Signal | Parallel (C-25) |
| Measurement Range | 40–141 KU |
| Display Units | KU, grams (g), centipoise (cP) |
| Resolution | 0.1 KU or 1 g |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.5% of full scale |
| Power Supply | 110/220 V, 50/60 Hz |
| Power Consumption | 20 W |
| Weight | 10 kg (22 lb) |
| Optional Accessories | Air purge kit, paint-specific spindle, container adapters for 1 quart, 1 pint, and ½ pint cans |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | KU-2 |
| Instrument Type | Rotational Viscometer |
| Measurement Range | 40–141 KU (Krebs Units), 32–1099 g, 27–5274 cP |
| Compliance | ASTM D562, ISO 2555, GB/T 9269 |
| Output | Analog voltage (0–5 V DC) for optional printer or data logger |
| Sample Volume | ~500 mL |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions | 22.9 × 15.2 × 30.5 cm |
| Weight | 6.8 kg |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | KU-3 |
| Instrument Type | Rotational Viscometer |
| Mounting Style | Benchtop (Fixed) |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 40–141 KU (Krebs Units) |
| Compliance | ASTM D562 |
| Core Component | KU-3 Viscometer Main Unit |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Instrument Type | Rotational Viscometer |
| Model | KU-3 |
| Measurement Principle | ASTM D562-compliant Krebs Unit (KU) viscosity measurement via rotational drag on standardized paddle-type spindle |
| Standard Spindle | KU-1030 |
| Sample Vessel Compatibility | 1-pint (473 mL) and ½-pint (237 mL) cans (ASTM D562 compliant) |
| Optional | Quart (946 mL) can fixture |
| Measurement Range | 40–141 KU |
| Equivalent Units | 32–1099 g (load), 27–5274 mPa·s (cP) |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.5% |
| Display | LED with selectable units (KU, g, cP) |
| Hold Function | Yes |
| Interface | Magnetic spindle coupling |
| Compliance | ASTM D562, ISO 2555 (indirectly applicable), GLP-ready operation |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LVT |
| Pricing | Available Upon Request |
| Measurement Range | 10–2,000,000 cP |
| Full-Scale Torque | 673.7 dyn·cm |
| Rotational Speeds | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm (8-speed stepped control) |
| Spindles Included | 4 standard spindles (SC4-14, SC4-21, SC4-27, SC4-29) |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | LVT/RVT |
| Type | Analog Dial Viscometer |
| Standard Spindles | LVT includes LV#1–LV#4 |
| Motor | Multi-speed, low-noise synchronous motor |
| Compliance | Designed to support ASTM D2196, ISO 2555, and USP <911> viscosity testing protocols |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | LVT/RVT/HAT/HBT |
| Instrument Type | Analog Dial-Reading Rotational Viscometer |
| Mounting Style | Benchtop Fixed Configuration |
| Operating Environment | Ambient Temperature (15–30°C) |
| Viscosity Range (cP) | LVT: 1–2M |
| RVT | 100–10M |
| HAT | 200–16M |
| HBT | 800–64M |
| Minimum Measurable Viscosity | 0.3 cP (LVT, with UL adapter) |
| Speed Range | 0.3–100 RPM (6–10 programmable speeds depending on model) |
| Spindle Count | 4 (LVT), 6 (RVT/HAT), 6 (HBT) |
| Accuracy | ±1% of full-scale reading |
| Repeatability | ±0.2% of reading |
| Compliance | Designed for ASTM D2196, ISO 2555, ISO 3219, and USP <911> viscosity testing protocols |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model Variants | LVT, RVT, HAT, HBT |
| Instrument Type | Rotational Viscometer (Analog Dial) |
| Viscosity Range | 1–64 × 10⁶ mPa·s (cP) |
| Accuracy | ±1% of full-scale range |
| Repeatability | ±0.2% |
| Operating Temperature | Ambient |
| Motor Type | Low-noise DC motor |
| Compliance | UL Class 1, Group D (explosion-proof variants available without motor) |
| Standard Accessories | Instrument body, set of spindles, support stand, guard leg, carrying case |
| Compatibility | Fully compatible with all Brookfield accessories (e.g., UL Adapter, thermosel systems, small sample adapters) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model Variants | LVT, RVT, HAT, HBT |
| Instrument Type | Benchtop Fixed-Base Rotational Viscometer |
| Operating Environment | Ambient Temperature (15–30°C) |
| Viscosity Range | 1 – 64,000,000 mPa·s (cP) |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Speed Control | Stepped Motor-Driven (8–10 RPM increments, model-dependent) |
| Display | Analog Dial Gauge (Torque %) |
| Calibration Compliance | Traceable to NIST standards |
| Warranty | 12 months limited parts and labor |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | RST |
| Instrument Type | Rotational Rheometer |
| Viscosity Range | 5.41 mPa·s to 10⁷ mPa·s (10⁷ cP) |
| Yield Stress Measurement Capability | Yes |
| Shear Stress Control Mode | Yes |
| Shear Rate Control Mode | Yes |
| Compliance | FDA 21 CFR Part 11 Ready (with Rheo 3000 Software) |
| Display | Full-color LCD touchscreen with graphical real-time curve rendering |
| Memory Slots | 11 programmable multi-step test protocols |
| Rotor Identification | Auto-reading barcode system |
| Gap Setting | Motorized and manual dual-mode adjustment |
| Geometry Compatibility | Cone-and-plate, parallel-plate, concentric cylinder (optional) |
| Software Option | Rheo 3000 PC-based control & data management suite |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | VTE |
| Instrument Type | In-line Viscometer |
| Viscosity Range | 10–10,000 cP |
| Output Signal | 4–20 mA (linear) |
| Accuracy | ±1% of full scale |
| Control Relay | 3 A solenoid-type |
| Enclosure Rating | NEMA 1 |
| Operating Environment | Ambient temperature |
| Compliance | Designed for continuous industrial process monitoring |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CAV4.1 |
| Instrument Type | Capillary Viscometer (Fixed Benchtop) |
| Kinematic Viscosity Range | 0.5–10,000 mm²/s (cSt) |
| Temperature Range | 20–150 °C |
| Temperature Resolution & Accuracy | ±0.01 °C |
| Compliance | ASTM D445, ASTM D446, ISO 3104, ISO 3105, IP 71, GB/T 265 |
| Sample Throughput | Dual-capillary parallel measurement |
| Integrated Control | Built-in industrial PC + 10.4″ color touchscreen |
| Software | VISCPRO (supports up to 4 CAV4.1 units per host PC) |
| Cleaning & Drying | Automated solvent rinse and compressed-air drying |
| Capillary Exchange | Tool-free, bath-oil–retaining design |
| Calibration | Single-point temperature calibration per capillary |
| Status Indication | Multi-color LED status lighting |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Certifications | CE |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CAV4.2 |
| Instrument Type | Fixed-Position Capillary Viscometer |
| Viscosity Range | 0.5–10,000 cSt |
| Temperature Range | 15–150 °C |
| Temperature Resolution | ±0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Compliance | CE Certified |
| Sample Throughput | Up to 24 samples unattended (1-hour cycle) |
| Display | 10.4-inch color touchscreen |
| Solvent Consumption Reduction | ~50% vs. conventional capillary systems |
| Cleaning Method | Automated air purge and solvent rinse |
| Capillary Options | Ubbelohde or ATLANTA-type viscometers |
| Calibration | Single-point temperature calibration per capillary |
| Sample Preheating | Individual sample heating up to 100 °C |
| Operating Environment | Ambient laboratory conditions |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CCS-2100F |
| Instrument Type | Rotational Viscometer (Cold Cranking Simulator) |
| Temperature Range | −35 °C to −5 °C |
| Temperature Resolution & Accuracy | ±0.05 °C |
| Apparent Viscosity Range | 1,500–27,000 mPa·s |
| Compliance | ASTM D5293, SAE J300-99, GB/T 6538 |
| Cooling Method | Solid-State Thermoelectric (No Refrigerants) |
| Sample Throughput | 30 Samples per Unattended Run |
| Control System | Windows-Based PC with CCS-RA Interface and LIMS-Ready Software |
| Power Supply | 230 V / 50 Hz / 1000 W |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CCS-2100LT |
| Instrument Type | Rotational Viscometer (Fixed-Base, Cold-Bath Configuration) |
| Temperature Range | −5 °C to −40 °C |
| Temperature Resolution & Accuracy | ±0.05 °C |
| Apparent Viscosity Range | 1500 mPa·s to 21000 mPa·s |
| Cooling Method | Solid-State Thermoelectric (Peltier) |
| Compliance | ASTM D5293, SAE J300-99, GB/T 6538 |
| Sample Throughput | Up to 30 samples per automated sequence |
| Control & Data Handling | PC-based automation with self-calibration routines and integrated wash cycle with programmable heating profile |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CCS2100-G6 |
| Instrument Type | Rotational Viscometer (Fixed-Base, Low-Temperature CCS) |
| Temperature Range | −40 °C to −5 °C |
| Temperature Accuracy | ±0.05 °C |
| Temperature Resolution | ±0.05 °C |
| Viscosity Range | 900–25,000 mPa·s (cP) |
| Compliance | ASTM D5293, SAE J300, GB/T 6538 |
| Sample Capacity | 14 samples (unattended) |
| Cleaning Method | Solvent-Free In-Situ Sample Flush |
| Calibration | Auto-Rotational Speed Calibration & User-Verifiable Temperature Calibration |
| Software | FlowHub™ Data Management Platform |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CMRV-4500F |
| Instrument Type | Rotational Viscometer (Fixed-Mount) |
| Temperature Range | –5 °C to –40 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling Method | Thermoelectric (Peltier) with Fluorine-Free Coolant Circulation |
| Compliance | ASTM D3829, D4684, D6896, D6821, SAE J300, GB/T 9171, SH/T 0562 |
| Software Platform | Windows 98/NT/XP Compatible Control System |
| Optional Accessory | Dedicated Rotor Kit for ASTM D6821 |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CT-2000F |
| Instrument Type | Fixed-Position Constant-Temperature Bath |
| Application | Capillary Viscometry |
| Temperature Range | 10 °C to 100 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Bath Capacity | 17 L |
| Power Supply | 240 V, 50/60 Hz, 1400 W |
| Dimensions (W×D×H) | 438 mm × 464 mm × 584 mm |
| Net Weight | 51.4 kg |
| Compliance | ASTM D445, ISO 3104 |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | DVR-1000 |
| Instrument Type | Fixed-Position Vacuum Viscometer |
| Operating Temperature Range | 0–40 °C |
| Vacuum Accuracy | ±0.5 mmHg at 300 mmHg setpoint |
| Compliance | ASTM D2171 |
| Display | Digital LED |
| Control Interface | Front-panel membrane keypad |
| Sensing Element | Solid-state pressure transducer (mercury-free) |
| Application Focus | Bitumen and asphalt viscosity testing under controlled vacuum |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | HTHS-II |
| Instrument Type | Capillary Viscometer |
| Standards Compliance | ASTM D5481, SAE J300, SH/T 0703-2001 |
| Operating Temperature | 150 °C |
| Shear Rate | 1.4 × 10⁶ s⁻¹ |
| Sample Throughput | 15–20 samples/hour |
| Safety Features | Inlet valve interlock, overtemperature cutoff |
| Software | Windows-based HTHS viscosity calculation software |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniAV |
| Instrument Type | Capillary Viscometer (Fixed-Station, Benchtop) |
| Viscosity Range | 0.5–10,000 mm²/s (cSt) |
| Temperature Range | 15–100 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C (at setpoint) |
| Compliance | ASTM D445, ASTM D446, ISO 3104, ISO 3105 |
| Sample Volume | 5–10 mL per test |
| Bath Volume | 1 L |
| Dimensions | 254 mm (W) × 533 mm (H) × 381 mm (D) |
| Connectivity | RS-232 |
| Software | VISCPRO II (Windows 98/NT/XP compatible) |
| Multi-unit Control | Up to 4 units per PC |
| LIMS Integration | Yes |
| Operating Humidity | 10–90% RH (non-condensing) |