Viscometers
Filter
Showing 91–120 of 120 results
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ROTAVISC me-vi Complete |
| Instrument Type | Benchtop Fixed-Position Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 100 – 40,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Torque Range | 0.7187 mN·m |
| Viscosity Accuracy (FSR) | ±1 % |
| Viscosity Repeatability (FSR) | ±0.2 % |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Interface | RS232, USB |
| IP Rating | IP40 |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Rotational Viscometer |
| Mounting Type | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 100 – 40,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Measurement Range | 0.7187 mN·m |
| Viscosity Accuracy (FSR) | ±1% |
| Viscosity Repeatability (FSR) | ±0.2% |
| Display | 4.3″ TFT Touchscreen |
| Interface | RS-232, USB |
| IP Rating | IP40 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Range | ROTAVISC lo-vi / me-vi / hi-vi I / hi-vi II Complete |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–6,000,000 mPa·s |
| Temperature Control Range | −100 °C to +300 °C |
| Temperature Resolution | 0.1 K |
| Accuracy | ±1 % of full scale |
| Repeatability | ±0.2 % of full scale |
| Speed Control | Continuously Variable (0.01–1,000 rpm) |
| Brand | MyiP |
|---|---|
| Origin | Shanghai, China |
| Model | DV-1 |
| Instrument Type | Benchtop Fixed Rotational Viscometer |
| Viscosity Range | 1–2×10⁶ mPa·s |
| Accuracy | ±2% (for Newtonian fluids) |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Spindles | LV#1, #2, #3, #4 |
| Operating Environment | Ambient temperature |
| Compliance | Conforms to GB/T 265 and JJG 1002 national standards for kinematic and dynamic viscosity measurement |
| Brand | MyiP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | NDJ-1 |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–1×10⁵ mPa·s |
| Accuracy | ±5% (for Newtonian fluids) |
| Rotors | No. 0 (optional), No. 1–4 |
| Rotational Speeds | 6, 12, 30, 60 rpm |
| Compliance | GB/T 265–1988 |
| Dimensions | 280 × 290 × 450 mm |
| Sample Temperature Control | External bath required (no integrated Peltier or heater) |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Model | 130-76-1-C |
| Instrument Type | High-Temperature Rotational Viscometer |
| Viscosity Range | 0.5–500,000,000 mPa·s |
| Fixed Speeds | 12 (600, 300, 200, 100, 60, 30, 20, 10, 6, 3, 2, 1 rpm) |
| Variable Speed Range | 0.006–1000 rpm |
| Speed Accuracy | ±0.001 rpm |
| Shear Rate Range | 0.01–1700 s⁻¹ |
| Heating Jacket | Stainless Steel, 150 W, Max Temp: 88 °C |
| Power Supply | 97–250 VAC, 200 W, 50/60 Hz |
| Dimensions | 44 × 38 × 24 cm |
| Weight | 8.6 kg |
| Interface | RS-232 (DB-9), Windows 2000 or later, min. 1024×768 resolution |
| Brand | Omnitek |
|---|---|
| Origin | Netherlands |
| Model | U-Visc Series |
| Instrument Type | Capillary Viscometer (Fixed-Station) |
| Viscosity Range | 0.15–25,000 mm²/s |
| Temperature Range | 15–150 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating Rate | 4 °C/min |
| Standards Compliance | ASTM D445, ASTM D446, ISO 3104, ISO 3105, GB/T 265, GB/T 30515, GB/T 11137 |
| Sample Volume | 8–16 mL |
| Autosampler Capacity | 32 positions (dual 16-position rotating carousel, one per capillary) |
| Timing Resolution | 0.001 s |
| Cleaning System | Dual-solvent (high-dissolving + high-volatility), corrosion-resistant fluidic path, vacuum-assisted waste evacuation |
| Environmental Control | Sealed autosampler chamber with negative-pressure waste collection |
| Brand | POWEREACH |
|---|---|
| Model | NDJ-1 |
| Type | Analog Rotational Viscometer |
| Portability | Benchtop (with integrated stand) |
| Operating Environment | Ambient temperature (10–35 °C) |
| Viscosity Range | 1–100,000 mPa·s |
| Rotors | Standard set includes #1–#4 |
| Speed Settings | 6, 12, 30, 60 rpm |
| Accuracy | ±5% for Newtonian fluids |
| Power Supply | 220 V ±10%, 50 Hz |
| Net Weight | 1.5 kg |
| Dimensions (W×D×H) | 400 × 370 × 150 mm |
| Compliance | Designed per GB/T 2794–2013 (Chinese national standard for viscometer calibration), compatible with ISO 2555 and ASTM D2196 test methodologies |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-4 |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Accuracy | ±5% (for Newtonian fluids) |
| Power Supply | 220 V ±10%, 50 Hz |
| Net Weight | 1.5 kg |
| Dimensions | 320 × 260 × 170 mm |
| Included Rotors | #1, #2, #3, #4 |
| Compliance | Designed for GLP-compliant routine viscosity monitoring in QC/QA and R&D environments |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-5S |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–100,000 mPa·s |
| Rotors | Standard #1–#4 |
| Speed Settings | 6, 12, 30, 60 rpm |
| Accuracy | ±2% for Newtonian liquids |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Temperature | 5–35 °C |
| Relative Humidity | ≤80% |
| Dimensions | 370 × 325 × 280 mm |
| Net Weight | 6.8 kg |
| Compliance | Designed for GLP-compliant routine QC environments |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–1,000,000 mPa·s |
| Rotational Speeds | 7.5 / 75 / 750 rpm |
| Accuracy | ±4% (for Newtonian fluids) |
| Dimensions (L×W×H) | 170 × 140 × 440 mm |
| Weight | 14 kg |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Compliance | Designed for routine QC and R&D in industrial and academic labs per ISO 2555 and ASTM D2196 principles |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Spindle Set | Standard #1–#4 spindles (optional #0 spindle for down to 0.1 mPa·s) |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Accuracy | ±2% for Newtonian fluids |
| Display | Backlit LCD with real-time spindle/speed/viscosity/% full-scale readout |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Environment | 5–35 °C, ≤80% RH |
| Dimensions | 370 × 325 × 280 mm |
| Net Weight | 6.8 kg |
| Brand | RheoSense |
|---|---|
| Origin | USA |
| Model | Initium |
| Instrument Type | Portable Microfluidic Viscometer |
| Viscosity Range | 0.2–2000 cP |
| Temperature Range | 4–70 °C |
| Sample Volume per Measurement | <5 µL |
| Shear Rate Range | Up to 10⁶ s⁻¹ |
| Compliance | ASTM D2196, ISO 2555, USP <911> |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported |
| Model | Auto-Falling Needle |
| Instrument Type | Benchtop Fixed-Position Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.5–1,000,000 cP |
| Measurement Principle | Gravitational Sedimentation of Calibrated Needle in Fluid |
| Shear Rate Range | 10⁻⁴–10³ s⁻¹ |
| Temperature Range | −40 to +150 °C |
| Sample Volume Options | 2.3, 3.6, 7.2, 9.6, 19.2, or 120 cm³ |
| Needle Materials | Borosilicate Glass, Fused Quartz, or Stainless Steel |
| Standard Needle Length | 10.2 cm (compact version: 4.2 cm) |
| Needle Density Options | 1.01, 1.1, 1.5, 2.0, 3.0, 5.0, and 8.0 g/cm³ |
| Timing Resolution | 0.01 s (optional 0.001 s) |
| Interface | RS-232 Serial Port |
| Accuracy & Repeatability | < ±1% |
| Compliance | ASTM D1545, ISO 12058-1, USP <911>, GLP-Compatible Data Logging |
| Brand | SBS |
|---|---|
| Origin | USA |
| Instrument Type | Portable Falling-Pin Viscometer |
| Sample Tube | Disposable 4.5 mL glass tube |
| Measurement Principle | Gravitational falling-pin (Stokes’ law-based) |
| Viscosity Range | 1–10⁸ cP |
| Temperature Control Range | 0–100 °C |
| Timing Resolution | 0.001 s |
| Pin Density Range | 6–300 g/cm³ |
| Accuracy & Repeatability | <1% |
| Interface | RS232 |
| Compliance | ASTM D1200, ISO 2555, USP <911> (for kinematic viscosity correlation) |
| Brand | SBS |
|---|---|
| Origin | USA |
| Instrument Type | Portable |
| Measurement Principle | Falling-Pin Viscometry |
| Viscosity Range | 5–10⁶ cP |
| Sample Volume | 4.5 mL |
| Accuracy | ±3% (PDV-100) |
| Repeatability | ±3% |
| Operating Environment | Ambient Temperature |
| Compliance | ASTM D7483, ISO 12058-1 (for falling-body viscometry), GLP-ready workflow support |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Model | NXS-11B |
| Viscosity Range | 2.8–1.78×10⁷ mPa·s |
| Shear Stress Range | 27.67–21,970 Pa |
| Shear Rate Range | 1.23–996 s⁻¹ |
| Speed Range | 5.6–360 rpm |
| Repeatability | ±1% FS (Newtonian fluids) |
| Construction | Stainless steel coaxial cylinder system |
| Instrument Type | Coaxial Cylinder Rotational Viscometer |
| Portability | Benchtop and handheld operation capable |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Model | AVS370 |
| Measurement Principle | Capillary Flow (Ubbelohde & Ostwald-type) |
| Time Range | 0.01–9999.99 s (resolution: 0.01 s) |
| Kinematic Viscosity Range | 0.35–1800 mm²/s (positive pressure mode) / 0.35–5000 mm²/s (vacuum mode) |
| Timer Accuracy | ±0.01% |
| Temperature Equilibration Time Setting | 0–20 min (in 1-min increments) |
| Replicate Runs | 1–10 per sample |
| Interface | RS-232C |
| Power Supply | 115/230 VAC, 50/60 Hz, 30 W |
| Housing | Anodized aluminum |
| Dimensions (W×H×D) | 225 × 205 × 320 mm |
| Weight | 5.4 kg |
| Compatible Viscometers | DIN Ubbelohde, ASTM Ubbelohde, DIN Micro Ubbelohde, Micro Ostwald, Cannon-Fenske Routine, TC-Ubbelohde, TC-Micro Ubbelohde |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Model | AVS370 |
| Measurement Principle | Capillary efflux time (kinematic viscosity) via photometric and thermal-conductivity detection |
| Pressure Modes | Positive pressure & vacuum aspiration |
| Timer Resolution | 0.01 s |
| Time Range | 0.01–9999.99 s |
| Kinematic Viscosity Range | 0.35–1800 mm²/s (cSt) under positive pressure |
| Timer Accuracy | ±0.01% |
| Pump Control | Microprocessor-regulated ViscoPump II (up to 4 units per chassis) |
| Temperature Equilibration Delay | 0–20 min (user-configurable) |
| Replicates per Sample | 1–10 |
| Interface | RS-232C |
| Power | 115/230 VAC, 50/60 Hz, 30 W |
| Enclosure | Powder-coated aluminum |
| Dimensions (W×H×D) | 225 × 205 × 320 mm |
| Weight | 5.4 kg |
| Compatible Viscometers | DIN Ubbelohde, ASTM Ubbelohde, DIN Micro Ubbelohde, Micro Ostwald, Cannon-Fenske Routine, TC-Ubbelohde, TC-Micro Ubbelohde |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Model | AVSPro |
| Measurement Principle | Capillary Flow (ASTM D445, ISO 3104, IP 71) |
| Kinematic Viscosity Range | 0.35–1200 mm²/s at ambient temperature |
| Accuracy | ±0.01% of reading + ±1 digit |
| Replicate Runs | 1–99 per sample |
| Temperature Equilibration Time | 0–99 min |
| Detection Methods | Dual-mode — Opto-electronic (for transparent/clear liquids) and Thermal Conductivity (TC) sensing (for opaque, dark, or highly viscous samples) |
| Sample Handling | Fully automated liquid handling with programmable injection sequence |
| Interface | RS-232/USB for PC integration |
| Compliance | Designed to meet ASTM D445, ISO 3104, ISO 17025 requirements for accredited viscosity testing laboratories |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Model | SMV-301 / SMV-301RT |
| Compliance Standards | JIS K6300, ISO 289, ASTM D1646, BS 1673 |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Rotational Speed Range (SMV-301RT) | 0.5–5 rpm |
| Mooney Viscosity Range | 0–200 M (optional 400 M) |
| Test Temperature Range | Ambient to 200 °C |
| Sample Dimensions | Ø ≈ 50 mm × Thickness ≈ 6 mm |
| Rotor Type | L-shaped |
| Curing Point Setting Range | 0–99.9 M (up to 10 points) |
| Viscosity Measurement Duration | 0–99 min 59 sec (up to 10 time points) |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Model | NDJ-1 / NDJ-4 |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Rotational Viscometer |
| Model | SNB-3 / SNB-4 (Color Touchscreen) |
| Viscosity Range | 1–2,000,000 mPa·s |
| Control System | MCS-51 Microcontroller-Based Stepper Motor Drive |
| Display | Full-Color TFT Touchscreen Interface |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Model | HAAKE Falling Ball |
| Instrument Type | Falling Ball Viscometer |
| Viscosity Range | 0.5 – 100,000 mPa·s |
| Temperature Range | −1 °C to +26 °C |
| Repeatability | < 0.5 % |
| Reproducibility | < 1 % |
| Measurement Tube Material | Borosilicate Glass (Tubes 1, 2, G) |
| Ball Materials | Nickel–Iron Alloy (Balls 3, 4, 5, 6) |
| Compliance | DIN 53015, ISO 120587 |
| Optional Accessories | Digital Stopwatch, Ball G (for gas viscosity), PT100 Temperature Sensor for HAAKE D50 Circulator |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Rotational Viscometer |
| Model | VT C / VT D / VT E |
| Viscosity Range | 15 – 40,000,000 mPa·s |
| Accuracy | ±1 % FSD |
| Repeatability | 0.2 % FSD |
| Speed Range | 0.01 – 200 rpm |
| Compliance | ISO 2555, ASTM D1084/D2196/D2556/D2983/D3232, BS 6075/5350 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rotational Viscometer |
| Model | HAAKE Viscotester D |
| Viscosity Range | 15 – 40,000,000 mPa·s |
| Compliance | ISO 2555 |
| Rotor Geometry | Standard Spindle (e.g., LV, RV, HA, HB series) |
| Shear Rate Range | Dependent on spindle geometry and rotational speed (typically 0.1–1000 s⁻¹) |
| Accuracy | ±1% of full scale (per ISO 2555 calibration requirements) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | VT550 |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 2 – 10⁷ mPa·s |
| Speed Range | 0.5 – 800 rpm |
| Torque Range | 0.1 – 50 mN·m (up to 400 rpm), 0.1 – 20 mN·m (up to 800 rpm) |
| Temperature Range | −40 °C to +350 °C (dependent on optional temperature control unit) |
| Compliance Standards | ISO 2555, ISO 3219, DIN 53018, DIN 53019 |
| Control Mode | Preset Programs (10 built-in), Controlled Deformation (CD) mode for yield stress determination |
| Software Integration | RheoWin (HAAKE proprietary software) |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | Tokisangyo Co., Ltd. |
| Type | Fixed-Mount Viscometer |
| Operating Environment | Ambient Temperature |
| Compatible Rotors | TH Series (for TVB-10HW/10RW/10UW/15H/15R/15U/25H/35H), TM Series (for TVB-10MW/15M/25/35L) |
| Sample Adapters | THM (low-volume, for TM-series rotors), THH (low-volume, for TH-series rotors), Low-Viscosity Adapter (for TM-series rotors) |
| Standard Axis Stand | TS-20 (compatible with TVB-10/15/25/35 models) |
| Measuring Range | 15–67.4 mPa·s |
| Maximum Torque | 15 μN·m |
| Instrument Category | Specialty Rotational Viscometer |
| Compliance | Designed per JIS Z 8803 and ISO 2555 for solution viscosity measurement |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | VM4300 |
| Viscosity Range | ≤200 µPa·s |
| Temperature Range | 14–300 K |
| Pressure Range | 0.1–4 MPa |
| Accuracy | ±3% |
| Measurement Principle | Vibrating Wire Method |
| Interface | USB |
| Operating System | Windows |
| Power Supply | 220 V, 50 Hz |
| Brand | ZVISCO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | IV6600 |
| Instrument Type | Capillary Viscometer |
| Viscosity Range | 0.3–5000 mm²/s |
| Temperature Control Range | 15–65 °C |
| Temperature Uniformity & Stability | ≤ ±0.01 °C |
| Timing Resolution | 0.0001 s |
| Measuring Time Range | 0.01–9999.99 s |
| Cleaning/Drying Fluid Consumption per Cycle | < 13 mL |
| Compatible Capillaries | Ubbelohde, Micro-Ubbelohde, Dilution-type Ubbelohde (compliant with ISO 3105, GB/T 1632–1993, ASTM D 446, DIN 51562) |
| Software Platform | Windows XP/7/8/10 |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 1.9 kW |
| Dimensions (L×W×H) | 1300 × 600 × 600 mm |