Voltage Breakdown Tester
Filter
Showing 1–30 of 38 results
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DST-80kV |
| Breakdown Voltage Range | 0–80 kV AC (adjustable) |
| Voltage Accuracy | ±1% |
| Electrode Gap | 2.5 mm (calibrated with feeler gauge, tolerance ±0.1 mm) |
| Standard Electrodes | 12.5–13 mm diameter disc electrodes (brass or stainless steel, polished) |
| Test Cup Material | IEC 60156-compliant ceramic or borosilicate glass |
| Cup Capacity | ~500 mL |
| Rise Rate | 0.5–5.0 kV/s (programmable) |
| Trip Current Threshold | 5 mA |
| Power Consumption | ≤200 W |
| Safety Interlock | Door-activated high-voltage cutoff |
| Grounding Resistance Requirement | ≤4 Ω |
| Compliance | IEC 60156:2025, ASTM D1816, GB/T 507–2002, DL/T 846.7–2004 |
| Brand | Aerospace Longitudinal |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-20KV Dielectric Strength Tester |
| Maximum Output Voltage | 20 kV AC/DC |
| Input Power | 220 V, 50–60 Hz |
| Voltage Ramp Rate | 0.05–5 kV/s (continuously adjustable) |
| Protection Response Time | <10 ms (main circuit breaker), <50 µs (solid-state backup) |
| Leakage Current Range | 1–100 mA (software-configurable) |
| Overcurrent Trip Range | 1–60 mA |
| Ripple Factor | ≤2% |
| Test Capacitance Options | 100 pF @ 20 kV, 100 pF @ 50 kV, 100 pF @ 100 kV, 100 pF @ 150 kV |
| Operating Temperature Range (Environmental Chamber) | –70 °C to +300 °C |
| Partial Discharge Sensitivity | 0.1 pC |
| Thermal Monitoring Accuracy | ±1 °C |
| Compliance | IEC 60270, IEC 60664, GB/T 1408.1, GB/T 1695, JJG 1005 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZDH-20kV |
| Breakdown Voltage | 20 kV |
| Compliance Standards | IEC 61621, ASTM D495, GB/T 1411 |
| Electrode Spacing | 4 mm or 6.35 mm (adjustable) |
| Arc Current Range | 10–40 mA |
| Output Voltage | AC/DC, 0–20 kV |
| Safety Features | Interlocked arc chamber, emergency stop, grounding resistance ≤2 Ω |
| Calibration Interval | Semi-annual (±2% voltage accuracy) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZH-50KV |
| Breakdown Voltage Range | 0–50 kV (AC/DC/Impulse) |
| Output Capacity | ≥10 kVA (compliant with GB/T 1408.1) |
| Voltage Accuracy | ≤1.5% FS (standard), optional ≤0.5% FS |
| Ramp Rate | 0.1–5 kV/s (adjustable), optional 0.01–10 kV/s (stepless) |
| Breakdown Detection Sensitivity | 0.1 mA (standard), optional 0.01 mA |
| Data Storage | 100 test records (standard), optional 1000+ with cloud backup |
| Safety Compliance | Triple Interlock Protection (door interlock, overcurrent cutoff ≤0.1 s, emergency stop), grounding resistance ≤4 Ω, discharge rod included |
| Environmental Options | Ambient (15–40 °C, RH ≤70%), optional high-temp chamber (RT to 200 °C, ±1 °C), optional low-temp chamber (−70 °C), oil-immersion testing (25# transformer oil, oil bath available) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Maximum Output Voltage | 100 kV AC/DC |
| Voltage Accuracy | ≤ ±1% |
| Ramp Rate | 0.01–5.0 kV/s (adjustable) |
| Current Detection Threshold | 1–30 mA (configurable) |
| Trip Response Time | ≤ 0.1 s |
| Data Sampling Rate | 500 Hz |
| Test Media | Air, Insulating Oil |
| Standard Electrode Diameters | 6 mm, 25 mm, 75 mm |
| Power Rating | Up to 10 kVA |
| Hold Time Range | 0–8 h |
| Compliance | IEC 60243-1, IEC 60243-2, GB/T 1408.1, GB/T 1408.2, ASTM D149, ASTM D877 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZJC-100KV |
| Price Range | USD 7,000 – 21,000 (FOB) |
| Maximum Output Voltage | 100 kV |
| Voltage Ramp Rate | 0.5–5 kV/s (continuously adjustable) |
| Voltage Measurement Range | 0–100 kV |
| Voltage Resolution | 1 V (10-bit A/D) |
| Breakdown Current Range | 0.1–100 mA |
| Current Accuracy | ±1% FS |
| Overvoltage Protection Threshold Accuracy | ±5% |
| Overcurrent Response Time | <1 ms |
| Flashover Auto-Restart Delay | 0–60 s (adjustable) |
| Safety Interlock Compliance | IEC 61010-1 |
| Data Sampling Rate | 500 Hz |
| Output Formats | CSV (raw), PDF (standard report) |
| Environmental Operating Conditions | 25±5°C, ≤65% RH |
| Electrode Material | Tungsten-Copper |
| Recommended Electrode Maintenance | Polishing with #800 grit sandpaper after every 50 tests |
| Transformer Oil Service Interval | Filtration required after 500 operating hours |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Max Output Voltage | 100 kV (AC/DC) |
| Input Voltage | AC 220 V ±10%, 50 Hz |
| Power Rating | 5 kVA |
| Voltage Regulation | Continuous, stepless (0–3000 V/s) |
| Voltage Measurement Accuracy | ≤ ±1% |
| Test Environments | Air or Transformer Oil Immersion |
| Safety Response Time | ≤ 0.01 s for overcurrent cutoff |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 0–85% RH (non-condensing) |
| Compliance | GB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, GB/T 3333, GB 12656, ASTM D149, ASTM D876, DIN 53481, IEC 60243, UNI 4291 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Max Output Voltage | 100 kV AC/DC |
| Voltage Measurement Range | 0–100 kV (AC/DC) |
| Voltage Accuracy | ±1.5% (10–100% of full scale) |
| Rise Rate Adjustment | 0.1–3 kV/s (continuously variable, no gear shifting) |
| Test Modes | Ramp-up, Step-up, and Hold (with programmable dwell time up to 4 h, extendable per DIN/VDE/IEC conventions) |
| Power Rating | 10 kVA |
| Overcurrent Protection | 1–30 mA (software-configurable) |
| Safety Features | Nine-level interlock system including overvoltage cutoff, door interlock, automatic discharge post-test, zero-voltage reset, independent grounding, short-circuit detection, and software operation validation |
| Dimensions (L×W×H) | 2100 × 1500 × 2100 mm |
| Net Weight | 1800 kg |
| Compliance | GB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, ASTM D149, GB/T 3333, GB/T 12656, HG/T 3330 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Maximum Test Voltage | 100 kV AC/DC |
| Voltage Accuracy | ≤2% |
| Rise Rate Range | 0.01–5 kV/s (adjustable in real time) |
| Test Modes | AC/DC, stepwise ramp, withstand, breakdown |
| Electrode Options | 6 mm sphere, 25 mm & 75 mm flat disc electrodes |
| Test Medium | air or insulating oil |
| Safety Protection | 9-level interlocked protection system |
| Power Rating | 10 kVA |
| Compliance | GB/T 1408.1–2016, GB/T 1408.2–2006, GB/T 1695–2005, ASTM D149–2023 |
| Software | PC-based control with real-time curve plotting, automatic breakdown detection, data logging, audit trail, and multi-sample parallel testing capability |
| Dimensions (L×W×H) | 1900 × 1300 × 1700 mm |
| Weight | 200 kg |
| Warranty | 3 years comprehensive, lifetime technical support |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Maximum Output Voltage | 100 kV |
| Compliance | GB/T 1408.1–2016, IEC 60243-1, ASTM D149 |
| Test Modes | Short-time, Stepwise (20 s/60 s), Ramp (120–600 s), Proof Testing |
| Electrode Configurations | Coaxial cylindrical, spherical, parallel plate, rod-to-rod, foil-wrapped tubular, and custom fixtures per ISO/IEC standards |
| Voltage Regulation Accuracy | ≤ ±2% of set value |
| Rise Time Control | Adjustable from 1 V/s to 5000 V/s |
| Measurement Uncertainty | ≤ ±3% (kV), traceable to national metrology standards |
| Safety Interlocks | Dual-channel overcurrent cutoff (<5 ms response), ground-fault detection, door-activated HV disable, arc-quenching chamber |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Output Voltage | AC/DC 0–100 kV |
| Output Power | 5 kVA |
| Voltage Measurement Accuracy | ≤ ±2% |
| Ramp Rate | 0.1–10 kV/s |
| Withstand Test Voltage Range | 10–100 kV (continuously adjustable) |
| Withstand Duration | 0–4 h (no-current condition) |
| Input | 220 V ±10%, 50 Hz ±1% |
| Dimensions (L×W×H) | 700 × 800 × 1650 mm |
| Weight | 100 kg |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 30–85% RH |
| Grounding Resistance Requirement | ≤ 4 Ω |
| Short-Circuit & Overcurrent Protection Response Time | ≤ 0.1 s |
| Compliance | GB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, ASTM D149 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Maximum Output Voltage | 100 kV |
| Compliance Standards | IEC 60243-1, ASTM D149, GB/T 1408.1, ISO 60243 |
| Voltage Regulation Accuracy | ±1% of full scale |
| Rise Rate Control | Adjustable from 0.1 to 5.0 kV/s (linear or stepwise) |
| Current Detection Range | 0.1 μA to 100 mA |
| Electrode Alignment Tolerance | ≤0.1 mm |
| Safety Certification | IEC 61010-1, CAT III 1000 V |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Breakdown Voltage Range | 0–100 kV (AC/DC) |
| Voltage Accuracy | ≤1% |
| Test Media | Air or Insulating Oil |
| Electrode Options | 25 mm, 75 mm, 6 mm (spherical, disk, rod configurations) |
| Power Capacity | 5 kVA or 10 kVA |
| Rise Rate | 10 V/s – 5 kV/s (continuously adjustable) |
| Safety Protection | 9-level interlocked protection system |
| Compliance | GB/T 1408.1–2006, GB/T 1695–2005, GB/T 3333–1999, ASTM D149, ASTM D3755, IEC 60243-1 |
| Dimensions (Standard) | 700 × 800 × 1300 mm (L×W×H), 100 kg |
| Dimensions (Large) | 1900 × 1300 × 1700 mm (L×W×H), 200 kg |
| Input Voltage | 220 V AC, 50/60 Hz |
| Maximum Hold Time | 8 hours |
| Data Interface | Optical-isolated acquisition, Bluetooth remote control |
| Software | Windows-based test management with real-time curve plotting, audit trail, export to Excel/Word, user access control, and GLP-compliant reporting |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Output Voltage | AC/DC 0–150 kV |
| Measurement Range | AC/DC 15–150 kV |
| Accuracy | ≤ ±2% |
| Ramp Rate | 1–5 kV/s |
| Hold Time | 0–4 h |
| Leakage Current Setting | 1–30 mA (software-controlled) |
| Input Power | AC 220 V ±10%, 50 Hz ±1% |
| Output Power | 15 kVA |
| Dimensions (L×W×H) | 1980 × 1220 × 1750 mm |
| Weight | 350 kg |
| Operating Environment | 15–30 °C, RH ≤ 85% |
| Grounding Requirement | Dedicated earth electrode ≥1.5 m depth |
| Compliance | GB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, GB/T 3333, HG/T 3330, GB 12656, ASTM D149 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Output Voltage | AC/DC 0–150 kV |
| Measurement Range | AC/DC 15–150 kV |
| Accuracy | ≤1% |
| Ramp Rate | 0.01–5 kV/s |
| Hold Time | 0–8 h |
| Leakage Current Setting | 1–30 mA |
| Input | AC 220 V ±10%, 50 Hz ±1% |
| Power Output | 15 kVA |
| Dimensions (L×W×H) | 1980 × 1220 × 1750 mm |
| Weight | 350 kg |
| Environmental Operating Range | 15–30 °C, RH ≤85% |
| Grounding Requirement | Dedicated earth electrode ≥1.5 m depth |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Maximum Output Voltage | 150 kV |
| Voltage Ramp Rate | 0.1–3 kV/s (adjustable) |
| Electrode Configuration | 12.5 mm polished spherical electrodes (Ra ≤ 0.2 µm), fixed gap 2.5 mm ± 0.05 mm |
| Breakdown Current Threshold | 1–100 mA (programmable), response time ≤ 10 µs |
| Temperature Control | Integrated oil bath, stability ±1 °C at 25 °C |
| Humidity Limit | <70 % RH in test chamber |
| Compliance | IEC 60156, ASTM D877, GB/T 507, GB 2536 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Maximum Output Voltage | 150 kV AC/DC |
| Voltage Range | 0–100 kV AC/DC |
| Ramp Rate | 0.05–10 kV/s (continuously adjustable) |
| Measurement Accuracy | ≤1% for AC/DC voltage |
| Output Ripple Factor | ≤2% |
| Test Duration | 0–48 h (current-free mode) |
| Oil Bath Temperature Range | Ambient to 300 °C |
| Electrode Configurations | φ25 mm & φ75 mm stainless steel electrodes |
| Power Rating | 10 kW |
| Dimensions (L×W×H) | 1600 × 1100 × 1500 mm |
| Working Height | 940 ± 30 mm |
| Work Surface | 1600 × 1100 mm |
| Overcurrent Protection | 1–100 mA |
| Sampling Capacitor | 100 pF / 100 kV |
| Interface | Bilingual (English/Chinese) touchscreen + PC-based control software |
| Safety Compliance | IEC 61010-1, IEC 60243-1, GB/T 1408.1, ASTM D149, ISO 60243-1 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Maximum Output Voltage | 150 kV AC/DC |
| Voltage Accuracy | ≤ ±3–5% |
| Adjustable Ramp Rates | 0.1–5 kV/s (7 preset steps) |
| Test Modes | AC/DC — Uniform Ramp, Stepwise Ramp, Hold-at-Voltage (Dielectric Withstand) |
| Compliance | GB 1408.1–2006, GB/T 1695–2005, GB/T 3333–2008, HG/T 3330–2003, GB 12656–1990, ASTM D149–2022 |
| Electrode Configurations | Ø25 mm & Ø75 mm stainless steel disk electrodes |
| Test Medium | Air or insulating oil |
| Safety Interlocks | 6-level hardware-enforced shutdown (door switch, key-controlled HV disconnect, zero-position lockout, overcurrent cutoff <100 ms, ground fault detection, DC discharge alarm) |
| Software Platform | Windows XP/7/8 native application with real-time curve plotting, multi-curve overlay, region zoom, manual data validation, Excel export, user role management, and audit-trail-capable test logging |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Maximum Output Voltage | 150 kV |
| Compliance | GB/T 1408.1–2016, IEC 60243-1:2013, ASTM D149–20 |
| Electrode Configurations | Cylindrical (6.4 mm & 25 mm diameter), Parallel-plate, Needle-to-plate |
| Voltage Ramp Rates | 0.5–2 kV/s (adjustable) |
| Sample Thickness Range | 0.1–3 mm |
| Environmental Control | 23 ± 2 °C, 50 ± 5 % RH (optional oil bath or SF₆ gas chamber) |
| Safety Standards | IEC 61010-1, Dual Grounding, Interlocked Enclosure, Emergency Stop |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Breakdown Voltage Range | 0–150 kV AC/DC |
| Voltage Accuracy | ≤2% |
| Rise Rate | 0.1–10 kV/s |
| Output Power | 5–10 kVA |
| Test Medium | Insulating oil or air |
| Electrode Options | 25 mm & 75 mm disc, 6 mm sphere, parallel-plate, cylindrical, conical, wire-type |
| Safety Protection | Nine-level interlock system (including door interlock, overcurrent cutoff <0.1 s, grounding monitoring ≤4 Ω, discharge circuitry) |
| Compliance | GB/T 1408.1–2006, GB/T 1408.2–2006, GB/T 1695–2005, ASTM D149–2022 |
| Operating Environment | 15–30 °C, 30–85% RH |
| Dimensions (L×W×H) | 700×800×1300 mm or 1900×1300×1700 mm |
| Weight | 100–200 kg |
| Warranty | 3 years full coverage, lifetime technical support |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50KV |
| Breakdown Voltage Range | 0–50 kV AC / DC |
| Voltage Accuracy | ≤1% |
| Test Medium | Air or Insulating Oil |
| Electrode Options | 25 mm, 75 mm, 6 mm spherical/plate electrodes |
| Ramp Rate | 0.1–3 kV/s (adjustable, continuous) |
| Test Modes | Stepwise ramp, constant-rate ramp, withstand voltage (0–6 h), gradient testing |
| Safety Protection | 9-level interlock system (overvoltage, overcurrent, short-circuit, door interlock, zero-voltage reset, post-test discharge, grounding, software lockout, electromagnetic discharge) |
| Power Input | 220 V AC, 5 kVA |
| Dimensions | 700 × 800 × 1300 mm (L×W×H) |
| Weight | ~150 kg |
| Compliance | GB/T 1408.1–2016, GB/T 1695–2005, GB/T 3333–1999, HG/T 3330, GB/T 12656–1990, ASTM D149, ASTM D3755 |
| Software | PC-based control with real-time curve plotting, data logging, audit trail, Excel/Word export, user access control, and GLP-compliant test report generation |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50KV |
| Maximum Output Voltage | 50 kV |
| Compliance | IEC 60243-2, GB/T 1408.2 |
| Voltage Resolution | 0.1 kV |
| Ramp Rate Range | 0.1–5 kV/s (continuously adjustable) |
| Trip Current Threshold | 1–100 mA |
| Electrode Options | IEC-standard spherical/cylindrical electrodes (6 mm or 25 mm diameter) |
| Environmental Control | 23 ± 2 °C, 50 ± 5 % RH |
| Measurement Accuracy | ±1 % of reading (voltage) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50KV |
| Maximum Output Voltage | 50 kV AC/DC |
| Voltage Measurement Range | 0–50 kV (AC/DC) |
| Power Capacity | 5 kVA |
| Rising Rate | 0.1–5 kV/s |
| Voltage Measurement Accuracy | ≤1% |
| Test Modes | Ramp-up, Step-up, and Hold-at-Voltage (Dielectric Withstand) |
| Safety Protections | Nine-level interlock system including overvoltage cutoff, overcurrent trip, short-circuit detection, safety door interlock, zero-voltage reset, post-test automatic discharge (electromagnetic + resistive), independent grounding, and software operation validation |
| Dimensions (L×W×H) | 1200 × 1050 × 1500 mm |
| Net Weight | ~200 kg |
| Compliance | GB/T 1408.1–2016, GB/T 1408.2–2016, GB/T 1695–2005, GB/T 507–2002, DL 429.9–1991, ASTM D149–2022 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50kV |
| Dielectric Breakdown Voltage Range | 0–50 kV |
| Input Power | AC 220 V ±10%, 50 Hz |
| Max Output Power | 3 kVA |
| Rise Rate Adjustment | 0.1–5 kV/s (adjustable) |
| Leakage Current Alarm Threshold | Adjustable (0.1–20 mA) |
| Voltage Accuracy | ±1.5% of reading (calibrated annually) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Grounding Resistance Requirement | ≤4 Ω |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50kV |
| Dielectric Breakdown Voltage | 50 kV |
| Compliance | GB/T 1408.1, IEC 60243-1, ASTM D149 |
| Voltage Type | AC/DC selectable |
| Electrode Configuration | Standard spherical/cylindrical electrodes (brass) |
| Safety Enclosure | Interlocked grounded test chamber with emergency stop |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50kV |
| Breakdown Voltage Range | 0–50 kV (AC/DC) |
| Compliance | IEC 60243, ASTM D149, GB/T 1408, GB 16935 |
| Safety Features | Overvoltage/overcurrent protection, automatic discharge, interlocked enclosure |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50KV |
| Breakdown Voltage | 50 kV |
| Voltage Accuracy | ≤2% |
| Ramp Rate | 10 V/s – 5 kV/s |
| Test Modes | AC/DC, Stepwise, Withstand, Ramp-to-Failure |
| Test Media | Air or Insulating Oil |
| Electrode Options | 6 mm, 25 mm, 75 mm diameter |
| Power Rating | 5 kVA |
| Safety Protection | 9-Level Interlocked Protection |
| Compliance | GB/T 1408.1–2006, GB/T 1408.2–2006, GB/T 1695–2005, ASTM D149 |
| Software | PC-based Control with Real-Time Curve Plotting, Data Logging, Audit Trail, and Multi-Sample Batch Testing |
| Dimensions (L×W×H) | 700×800×1300 mm / 1900×1300×1700 mm |
| Weight | 100 kg / 200 kg |
| Warranty | 3 Years Full Coverage, Lifetime Technical Support |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50kV |
| Maximum Output Voltage | 50 kV |
| Voltage Regulation Range | 0–50 kV AC/DC |
| Ramp Rate | 0.1–5 kV/s (adjustable) |
| Breakdown Detection | Dual-threshold (current ≥1–10 mA + voltage drop >10%) |
| Compliance | IEC 60243-1, ASTM D149, GB/T 1408.1 |
| Safety Enclosure | 1.5 mm 304 stainless steel shielded chamber (≥60 dB shielding effectiveness) |
| Data Acquisition | 100 kHz sampling rate |
| Environmental Compensation | Real-time temperature/humidity correction (0.5%/°C) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50kV |
| Maximum Output Voltage | 50 kV |
| Compliance | IEC 60243, ASTM D149, IEC 60156, GB/T 13542 |
| Electrode Configurations | Sphere-Plate (Φ6 mm sphere vs. 25 mm plate) and Three-Electrode System |
| Temperature Control | 23 ± 2 °C |
| Relative Humidity Control | 50 ± 5 % RH |
| Voltage Waveform | 50 Hz AC sine wave (THD ≤ 5 %) or DC (ripple ≤ 3 %) |
| Safety Enclosure | Explosion-resistant viewing window rated ≥ 75 kV |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | C-50KV |
| Max Output Voltage | 50 kV AC/DC (RMS) |
| Input Voltage | AC 220 V |
| Power Rating | 3 kVA |
| Voltage Ramp Rate | 0.1–5.0 kV/s (adjustable) |
| Compliance | GB/T 1981.2–2003, GB/T 7113.2–2005, GB/T 10580–2003, ISO 293, ISO 294-1, ISO 294-3, ISO 295, ISO 10724, IEC 60296, IEC 60455-2, IEC 60674-2 |