Vulcanizometer
Filter
Showing all 6 results
| Brand | ALPHA (USA) |
|---|---|
| Origin | USA |
| Model | Premier MDR |
| Compliance | ASTM D5289, ISO 6520, DIN 53529 |
| Oscillation Frequency | 100 CPM (1.677 Hz) |
| Oscillation Amplitude | ±0.2°, ±0.5°, ±1.0°, ±3.0° (standard ±0.5°) |
| Temperature Range | 40–230 °C (100–446 °F) |
| Torque Range | 0.01–225 dN·m |
| Cavity Volume | ~1.43 cm³ (87.5 mm³ nominal |
| recommended sample volume | 1.84 cm³ / 112.5 mm³) |
| Pressure Channel | 0–8300 kPa (0–1200 psi) |
| Power Supply | 100–130 VAC ±10%, 60 ±3 Hz, 10 A or 200–260 VAC ±10%, 50 ±3 Hz, 5 A |
| Automation Options | 5-position manual test station or 16–144-position automated sample handling system |
| Software | Ultima Enterprise Pathfinder (Eclipse optional) |
| Brand | GOTECH TESTING MACHINES CO., LTD. |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China Market) |
| Model | MD-3000-A |
| Pricing | Upon Request |
| Standard Compliance | ASTM D5289, GB/T 16584, ISO 6502 |
| Temperature Range | Ambient to 230 °C |
| Torque Range (Elastic) | 1–200 lb-in |
| Torque Range (Viscous) | 0.3–200 lb-in |
| Torque Resolution | 0.001 unit (selectable unit: kg-cm, lb-in, N·m, dN·m) |
| Oscillation Frequency | 10–300 cpm |
| Oscillation Angle | ±0.2° to ±3.0° (0.001° digital resolution, software-defined) |
| Temperature Accuracy | ±0.3 °C |
| Temperature Readout Resolution | 0.1 °C |
| Heating Rate | 30 °C to 190 °C in <5 min 30 sec |
| Temperature Stabilization Time (post-closing) | ≤50 sec to ±0.3 °C |
| Die Configuration | Fully sealed cavity with O-ring isolation |
| Maximum Applied Force | 0–1000 kg |
| Actuation System | Direct-drive servo motor |
| Control Core | DSP-based real-time processor with DFT algorithm implementation |
| Power Supply | 1-phase AC 220 V ±10%, 50/60 Hz, 10 A |
| Dimensions (W×D×H) | 68 × 80 × 130 cm |
| Weight | 220 kg |
| Brand | Hongtuo |
|---|---|
| Origin | Guangdong, China |
| Model | HT-LH30 |
| Type | Plate Vulcanizer |
| Heating Method | Cartridge Heater |
| Pressure Range | 0–30 Ton (adjustable) |
| Weight | ~780 kg |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±3 °C |
| Power Supply | 3-phase 5-wire AC 380 V |
| Total Power | 8 kW |
| Platen Dimensions | 300 × 300 mm |
| Platen Spacing | 0–80 mm |
| Exhaust Cycles | 0–10 (programmable) |
| Timing Range | 0.1 min – 99 min – 9.9 h (LED digital timer) |
| Cooling | External tap water cooling |
| Platen Configuration | Dual-layer (upper heated, lower cooled) |
| Surface Finish | Mirror-finish hard chromium plating |
| Platen Material | High-strength corrosion- and heat-resistant alloy steel |
| Control Mode | Self-tuning PID with temperature auto-compensation |
| Mobility | Brake-equipped casters |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-50T |
| Price Range | USD 4,200 – 7,000 |
| Total Force | 500 kN (50 metric tons) |
| Working Pressure | 16 MPa |
| Platen Size | 400 × 400 mm |
| Unit Platen Pressure | 3.125 MPa |
| Number of Heating Zones | 2 |
| Platen Spacing | 125 mm |
| Piston Stroke | 250 mm |
| Piston Rising Speed | 12 mm/s |
| Heating Power per Platen | 3 kW |
| Max Operating Temperature | 300 °C |
| Net Weight | ~1,200 kg |
| Gross Weight | ~1,600 kg |
| Motor Specifications | High-Pressure Pump — 1.5 kW, 1400 rpm |
| Overall Dimensions | 1295 × 450 × 1686 mm |
| Brand | MonTech |
|---|---|
| Origin | Germany |
| Model | MDR 3000 |
| Standard Compliance | ISO 6502, ASTM D5289, DIN 53529 |
| Cavity Type | Sealed Dual-Conical |
| Drive System | Direct-Drive DC Servo Motor |
| Oscillation Frequency | 1.667 Hz |
| Amplitude Range | Software-Controlled ±0.01° to 5° (mechanical fixed option: 0.5°) |
| Temperature Range | Ambient to 232 °C |
| Measured Parameters | Torque (dN·m), Temperature (°C), Frequency (Hz), Strain (%), Derived Moduli (S′, S″, S*, tan δ) |
| Cavity Material | Hardened & Polished Stainless Steel |
| Enclosure | Anodized Aluminum Alloy Housing |
| Control Interface | Dedicated PC with MonControl v5.x (32-bit Windows-based Analysis Suite) |
| Data Output | Real-time torque/temperature curves, modulus profiles, cure kinetics (ts1, tc50, tc90), hysteresis analysis |
| Brand | Prescott |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Rheoline MDR |
| Price | Upon Request |
| Standard Compliance | ISO 6502, ASTM D5289 |
| Oscillation Frequency | 1.67 Hz |
| Oscillation Amplitude Options | 0.5° (standard), 1.0° or 3.0° (optional) |
| Temperature Range | 35–250 °C |
| Temperature Control | Digital PID |
| Torque Units | in·lb, dN·m |
| Temperature Units | °C, °F |
| Pressure Units (optional) | psi, kg/cm² |
| Time Format | min/sec, min/decimal, sec |
| Output Parameters | Elastic Modulus (G′), Viscous Modulus (G″), Tan δ, Curing Rate, Cavity Pressure (optional) |
| Data Storage | Microsoft Access or SQL database |
| Optional Accessories | Programmable multi-zone heating, Eccentric oscillating die, Cavity pressure transducer, Automated sample loader, Volumetric sample cutter |
| Software | Windows-based proprietary test platform with SPC module (optional), GLP/GMP-compliant audit trail support |