| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | GDE |
| Heating Power | 900 W |
| Temperature Range | Ambient to 105 °C |
| Temperature Accuracy | ±0.2 °C |
| Water Bath Chamber | Transparent Polycarbonate (Max Temp: 105 °C) |
| Dimensions (W×H×D) | 413 × 295 × 410 mm |
| Weight | 6.2 kg |
| Water Requirement | Deionized Water Recommended |
| Stirring | Integrated Magnetic Stirrer |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | DK 20 Digester System |
| Max Temperature | 450 °C |
| Temperature Uniformity | ±0.5 °C |
| Sample Capacity | 20 × 250 mL tubes (Ø42 mm) |
| Heating Block Material | Anodized aluminum |
| Housing Material | Stainless steel |
| Power Consumption | 13% lower than previous generation |
| Interface | 4-button digital control panel with tilted, chemically resistant front display |
| Optional Accessories | COD support rack, KS 1000 fume neutralizer |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Cubis® MSA2.7S-0TR-DF |
| Instrument Type | Ultra-Micro Balance |
| Maximum Capacity | 2.1 g |
| Readability | 0.0001 mg |
| Calibration | Internal, isoCAL |
| Compliance | ISO/IEC 17025, USP <41>, <1251>, FDA 21 CFR Part 11 (with Q-Apps & audit trail enabled) |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | rapid CS cube |
| Detection Principle | High-Temperature Combustion + Non-Dispersive Infrared (NDIR) Detection |
| Sample Throughput | Up to 60 samples unattended (standard), optional 80/120-position autosamplers |
| LOD (S in coal) | ≤2 ppm |
| Warranty | 10 years on combustion furnace and thermal conductivity detector (TCD) |
| Compliance | Designed for ISO 15594, ASTM D4294, ASTM D7622, and USP <281> carbon/sulfur testing environments |
| Software | vario LINK with full audit trail, 21 CFR Part 11-compliant user management and electronic signature support |
| Optional Modules | Chlorine detection (solid-state electrochemical sensor), TOC/TIC dual-module configuration |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Cubis® MSA6.6S-0CE-DF |
| Instrument Type | Ultra-Micro Balance |
| Maximum Capacity | 6.1 g |
| Readability | 0.001 mg |
| Weighing Range | 5–20 g |
| Calibration | Internal, isoCAL |
| Compliance | ISO/IEC 17025, USP <41>, <1251>, GLP/GMP-ready |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | acquray TOC |
| Detection Principle | High-Energy UV-Persulfate Wet Oxidation |
| LOD (TOC in Water) | 2 ppb |
| Sample Types | Liquid (aqueous), Solid, Suspended Particulates |
| Optional Modules | Solid TOC, TN (Total Nitrogen), TP (Total Phosphorus) |
| Automation | Optional Autosampler (up to 109 positions) |
| Compliance | Designed for ISO 8245, ASTM D5903, USP <643>, EPA Method 415.3 & 9060A |
| Calibration | Fully Automated Predefined Calibration Sequences |
| Maintenance | Predictive Alert System with Access-Optimized Component Layout |