X-ray Instrument Components and Operating Systems
Filter
Showing 31–37 of 37 results
| Brand | GKInst |
|---|---|
| Model | NFC |
| Type | Flow-through X-ray Transmission Cell |
| Window Material | Silicon Nitride (Si₃N₄) |
| Window Size | 1.5 mm × 1.5 mm |
| Window Thickness | 200 nm |
| Cell Volume | 5 mL |
| Cell Body Thickness | 1 mm |
| Fluidic Interface | M6 threaded port |
| Noise Suppression | Optimized laminar-flow pump coupling and acoustic decoupling mount |
| Brand | GKINST |
|---|---|
| Model | GK-THMS350V |
| Max Temp | 350 °C |
| Min Temp | −195 °C |
| Max Heating Rate | 150 °C/min |
| Max Cooling Rate | 30 °C/min |
| Temp Resolution | < 0.05 °C |
| Temp Stability | < 0.05 °C |
| Control Algorithm | PID Dynamic Regulation |
| Sensor Type | PT100 Platinum Resistance Thermometer |
| Brand | Oxford Instruments |
|---|---|
| Origin | USA |
| Model | 5000 Series |
| Max Anode Current | 1.0 mA |
| Max Anode Voltage | 50 kV |
| Max Power | 50 W |
| Filament Nominal Voltage | 2.0 V @ 50 kV, 1 mA |
| Filament Max Current | 1.7 A |
| Stability (4 hr) | ±0.2% |
| Nominal Focal Spot Size | 110 µm |
| Anode Material Options | W, Mo, Rh (custom anodes available) |
| Beryllium Window Thickness Options | 75 µm, 125 µm, 250 µm |
| Approx. Weight | 1.816 kg (4 lbs) |
| Cooling Method | Compressed Air @ 150 CFM |
| Beam Divergence Angle | 25° |
| Brand | Oxford Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | General Distributor |
| Origin Category | Imported |
| Model | UltraBright |
| Price Range | USD 0 – 9,999 |
| Max Anode Current | 1.0 mA |
| Max Anode Voltage | 50 kV |
| Max Power | 50 W |
| Filament Nominal Voltage | 2.0 V @ 50 kV, 1 mA |
| Filament Max Current | 1.7 A |
| Stability (after 4 hrs) | ±0.2% |
| Nominal Focal Spot Size | 110 µm |
| Anode Materials | W, Mo, Rh (custom options available) |
| Beryllium Window Thickness | 125 µm (optional: 75 µm or 250 µm) |
| Approx. Weight | 1.816 kg (4 lbs) |
| Cooling Method | Compressed Air @ 150 CFM |
| Beam Divergence Angle | 25° |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Line | XD-6 Series |
| Price Range | USD 42,000 – 70,000 |
| Brand | Princeton Instruments |
|---|---|
| Sensor Type | Back-illuminated or front-illuminated deep-depletion CCD |
| Energy Range | 3–20 keV |
| Window Material | Vacuum-integrated beryllium (Be) |
| Cooling | Thermoelectric (TE) cooling to –70 °C |
| Readout Architecture | Dual-amplifier selectable for low-noise or high-dynamic-range mode |
| Software Support | LightField v8.x, PICAM SDK, LabVIEW® and MATLAB® integration |
| Compliance | ASTM E1316, ISO/IEC 17025-compatible operation, FDA 21 CFR Part 11-ready audit trail (via LightField) |
| Brand | XOS |
|---|---|
| Origin | USA |
| Model | Mini-Beam |
| Tube Type | Metal-Ceramic |
| Target Materials | Ag, Rh, W, Cu, Cr |
| Operating Voltage | 4–60 kV |
| Beam Current | 5–200 µA |
| Max Power | 12 W |
| Cooling | Forced Air |
| Operating Temp | –10 to +50 °C |
| Input Power | 110/220 VAC, 50/60 Hz |
| Dimensions | 305 × 102 × 76 mm (12 × 4 × 3 in) |
| Weight | 1.95 kg (4.3 lbs) |
| Focal Spot Size | ≤5 µm FWHM @ Rh Kα (20.162 keV) |
| Flux Gain vs. Pinhole | >1000× |
| Capillary Options | PF-004/PF-010/PF-020/PF-050 (focusing) & PC-004/PC-006/PC-010/PC-015 (collimating) |