X Ray Stress Analyzer
Filter
Showing all 11 results
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | AreX D |
| X-ray Source | 50 W Mo microfocus tube with Zr filter |
| Cooling | Air-cooled |
| Detection | High-resolution USB camera for precise sample positioning |
| Safety | Interlocked X-ray shielding system |
| Measurable Diffraction Peaks | Austenite (220), (311) |
| Measurement Time | < 3 minutes per sample |
| Compliance | ASTM E975-22 Standard |
| Minimum Detectable Austenite Content | 0.5 vol% |
| Sample Compatibility | Flat, polished metallic specimens (steel, stainless steel, tool steels, bearing alloys) |
| Software | Integrated Windows-based analysis suite with peak integration, phase quantification, and report generation |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | AREX L |
| Compliance | ASTM E975 |
| Measurement Principle | X-ray Diffraction (XRD) |
| Detection Limit | ≤0.5% austenite |
| Target Material | Ferrous alloys (steel, cast iron, heat-treated components) |
| X-ray Source | High-power ceramic X-ray tube |
| Optics | High-focus single-capillary collimator |
| Detector | High-resolution CCD detector |
| Stability Control | Precision closed-loop feedback circuit for HV/current regulation |
| Data Acquisition | Multi-peak intensity ratio analysis (austenite {220}, {311} / ferrite {200}, {211}) |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | EDGE |
| Compliance | ASTM E915, EN 15305 |
| Detector | Linear silicon strip detector with single-photon counting technology |
| Cooling | Air-cooled |
| X-ray Source | Interchangeable microfocus X-ray tubes |
| Fluorescence Suppression | Integrated X-ray fluorescence rejection |
| Measurement Time | Minutes per point (vs. hours for conventional systems) |
| Portability | Fully integrated into carry-on compliant transport case |
| Safety Options | Optional radiation shielding enclosure for benchtop operation |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | MagStress5c |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) |
| Sample Type | Ferromagnetic Metals (e.g., carbon steel, alloy steel, cast iron) |
| Portability | Integrated battery-powered handheld system with touch-screen interface and USB connectivity |
| Output | Quantitative residual stress in MPa, graphical trend visualization, calibration curve support |
| Compliance Context | Designed for field-deployable non-destructive evaluation (NDE) in accordance with ASTM E1447, ISO 20956, and EN 10328 guidelines for magnetic methods of stress assessment |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | STRESS-X |
| Compliance | ASTM E915, EN 15305 |
| Motion System | 6-axis robotic arm |
| Deployment Options | Benchtop shielded enclosure or mobile four-wheel alloy cart |
| Measurement Principle | Sin²ψ X-ray diffraction (XRD) |
| Application Scope | Non-destructive residual stress mapping on metallic components |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | CamScan1000 |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) |
| Cycle Time | 6–8 seconds per lobe |
| Channel Configuration | Single- or Multi-channel |
| Detection Type | Non-destructive, quantitative surface burn assessment |
| Alarm Threshold | User-definable |
| Compliance | Designed for ISO/IEC 17025-aligned QA environments |
| Application Scope | In-line and off-line camshaft inspection |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | CrankScan200 |
| Detection Principle | Magnetic Barkhausen Noise (MBN) |
| Measurement Type | Non-Destructive, Surface & Near-Surface Integrity Assessment |
| Channel Configuration | Single- or Multi-Channel Probe Support |
| Probe Compatibility | Curved-Surface Optimized Sensors for Journal, Fillet, Flank, and Crankweb Geometry |
| Alarm Thresholding | User-Configurable Signal Amplitude & Statistical Deviation Limits |
| Compliance Framework | Supports ISO 28671 (Non-destructive testing — Magnetic Barkhausen noise testing — General principles), ASTM E3094 (Standard Guide for MBN Testing of Ferromagnetic Materials), and GLP/GMP-aligned data traceability |
| Brand | Stresstech Oy |
|---|---|
| Country of Origin | Finland |
| Model | G2 |
| Portability | Field-deployable, integrated water-cooled X-ray generator |
| Safety Compliance | EN 61000-6-4, EN 61000-6-2, IEC 61000-4-3, CE-marked for industrial use |
| Detector Type | High-resolution silicon strip detector (SSD) or CCD-based imaging detector (configurable) |
| X-ray Source | Microfocus tungsten anode tube, 30–50 kV adjustable, <100 µm focal spot |
| Measurement Method | Sin²ψ technique with automated ψ-tilt stage (±45° range) |
| Data Acquisition | Real-time diffraction pattern capture, peak fitting via pseudo-Voigt deconvolution |
| Software Platform | RoboScan™ v5.x with GLP-compliant audit trail and 21 CFR Part 11-ready user access control |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | GearScan |
| Measurement Principle | Barkhausen Noise Analysis (BNA) |
| Diameter Range | 5–2000 mm |
| Module Range | 1–70 |
| Measurement Time per Tooth | 2–30 s (dependent on geometry and surface condition) |
| Motion Control | Computer-controlled precision DC servo motor with linear-bearing-driven probe |
| Compliance | Designed for ISO 13302, ASTM E2964, and EN 10327-based residual stress and grinding burn assessment workflows |
| Software | RoboScan™ PC-based acquisition and analysis suite with audit trail, user access levels, and GLP/GMP-ready reporting |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | Rollscan 250 |
| Type | Non-Destructive Surface Integrity Analyzer |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) Analysis |
| Compliance | ISO 28640, ASTM E3147 (under development), EN 10327 (applicable for grinding burn assessment) |
| Sensor Interface | Plug-and-play modular connector |
| Motion Control | Motorized X/Z linear axes + A/T rotational axes |
| Software Platform | EasyGear v5.x (Windows-based, FDA 21 CFR Part 11 compliant configuration available) |
| Data Output | ASCII, CSV, XML |
| Cabinet Integration | Integrated control cabinet with main isolator switch, LED status indicators, emergency stop, door interlock, and Ergotron-display mounting |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | XStress 3000 |
| Application | Residual stress measurement via X-ray diffraction (XRD) |
| Portability | Field-deployable, battery-optional operation |
| Power Requirement | Single AC source (100–240 V, 50/60 Hz) |
| Setup Time | ≤10 minutes |
| Communication Interface | Ethernet, USB, and embedded Windows-based controller |
| Compliance | Designed for ISO 21940, ASTM E915, and EN 15305-compliant residual stress evaluation |