- All
- Favorite
- Popular
- Most rated
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T6WZP05 Series |
| Pricing | Available Upon Request |
| Brand | Xiatech |
|---|---|
| Model | TC3300 |
| Measurement Principle | Transient Hot Wire Method |
| Temperature Range | –150 °C to Ambient |
| Thermal Conductivity Accuracy | ±5% |
| Repeatability | ±3% |
| Sample Forms | Solid, Paste, Powder, Liquid |
| Sample Dimensions | ≥25 mm (solid edge length) |
| Test Atmosphere | Air |
| Compliance | ASTM C1113, ASTM D5930, GB/T 10297, GB/T 11205 |
| Maximum Operating Pressure | High-Pressure Compatible |
| Sample Throughput | Single-sample per cycle |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | T6000 |
| Temperature Range | -200 °C to +250 °C |
| Accuracy | ±0.02 °C |
| Probe Diameter Options | Φ4 mm, Φ5 mm, Φ6 mm |
| Probe Length Options | 50–400 mm |
| Construction | Hermetically Sealed, Waterproof (IP67 Rated), Stainless Steel Sheath |
| Sensor Element | Pt100 or Pt1000 (IEC 60751 Class A or AA) |
| Output | 2-wire / 3-wire / 4-wire configurable |
| Stability | ≤0.01 °C/year typical drift |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | T1000S |
| Temperature Measurement Principle | Resistance-based (RTD/SPRT compatible) |
| Measurement Method | Contact |
| Temperature Range | −200 °C to +850 °C |
| Resolution | 0.001 °C |
| Accuracy | ±0.01 °C (full scale) |
| Long-term Stability | <5 mK/year |
| Channels | 10 simultaneous |
| Sampling Interval | 1 s per channel |
| Units | °C / °F / K / Ω |
| Built-in Standard | ITS-90 |
| Display | 7-inch capacitive touchscreen |
| Interface | USB |
| Probe Connector | 5-pin straight plug |
| Power Supply | 110/220 VAC, 50/60 Hz |
| Dimensions (L×W×H) | 365 × 260 × 160 mm |
| Operating Environment | 0–40 °C, ≤65% RH |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3200L |
| Measurement Principle | Transient Hot Wire (THW) Method |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | 0.1–15 MPa (optional pressure control) |
| Thermal Conductivity Range | 0.0005–5 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Sample Volume Requirement | ≥40 mL |
| Measurement Time | ≤2 s |
| Sample Forms | Liquids and gases |
| Test Atmospheres | Vacuum, air, inert gas |
| Dimensions (L×W×H) | 550×500×650 mm |
| Compliance Standards | ASTM D2717, ASTM D7896 |
| Data Interface | USB |
| Operating System | Windows |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | VM4300 |
| Viscosity Range | ≤200 µPa·s |
| Temperature Range | 14–300 K |
| Pressure Range | 0.1–4 MPa |
| Accuracy | ±3% |
| Measurement Principle | Vibrating Wire Method |
| Interface | USB |
| Operating System | Windows |
| Power Supply | 220 V, 50 Hz |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | T6000 |
| Temperature Measurement Principle | Resistance-based (RTD) |
| Measurement Method | Contact |
| Temperature Range | −200 to +1600 °C |
| Resolution | 0.001 °C |
| Accuracy | ±0.01 °C (for RTDs), ±0.3% FS (for thermistors), ±0.2% FS (for thermocouples) |
| Long-term Stability | <0.005 °C/year |
| Display | 7-inch capacitive touchscreen |
| Channel Configuration | Dual-channel, expandable |
| Sensor Compatibility | ITS-90-compliant platinum resistance thermometers (Pt100, Pt1000), NTC/PTC thermistors, and standard thermocouples (J, K, T, E, R, S, B, N) |
| Calibration Standard | Built-in ITS-90 reference implementation |