Empowering Scientific Discovery

Yingxiao Instruments & Meters (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
Model3SP-Ethanol-1000
Measurement Range0–1000 ppm
Overload Capacity2000 ppm
Response Time (t₉₀)≤30 s
Sensitivity14 ±5 nA/ppm
Dimensions15 × 15 × 3.8 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelO2-G1 (Miniature)
Measurement Range0–30% O₂
Operating Lifetime>12 months
DimensionsΦ20.3 × 10.2 mm
Output Current65–85 µA @ 22°C, 20.9% O₂
Response Time (t₉₀)<18 s
Weight<7 g
Operating Temperature−30 to +55°C
Pressure Range80–120 kPa
Humidity Range5–95% RH (non-condensing)
Storage Life6 months
Load Resistance47–100 Ω
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelO2-M2
Measurement Range0–30% O₂ (v/v)
Operating Life>24 months (to 85% of initial output)
DimensionsØ20.3 × 16.8 mm
Typical Output80–120 nA @ 22°C, 20.9% O₂
Response Time (t₉₀)<15 s (20.9% → 0% O₂, 47 Ω load)
Linearity Error<±0.6% FS (zero & 400 ppm points)
Weight<16 g
Operating Temperature−30 to +55°C
Pressure Range80–120 kPa
Relative Humidity Range5–95% RH (non-condensing)
Storage Stability6 months (unpowered, sealed)
Load Resistance47–100 Ω
Sensor TypePotentiostatically controlled electrochemical cell
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelHCN-A1
Measurement Range0–100 ppm
Sensitivity45–85 nA/ppm
Response Time (t₉₀)<70 s
Linear Range0–40 ppm
Full-Scale Error±4–8 ppm
Overload Capability150 ppm
Resolution<0.05 ppm
DimensionsØ20.2 × 16.5 mm
Operating Temperature−30 to +50 °C
Operating Humidity15–90 %RH (non-condensing)
Load Resistance10–33 Ω
Expected Service Life12 months
Storage Shelf Life6 months
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelSOH-A2
Detection PrinciplePotentiostatic 3-Electrode Electrochemistry
Gas TargetsSulfur Dioxide (SO₂) and Hydrogen Sulfide (H₂S)
SO₂ ChannelRange 0–20 ppm, Resolution <0.2 ppm, t₉₀ <15 s, Sensitivity 140–250 nA/ppm (at 10 ppm), Zero Current <+0.2 ppm, Linearity Error ±2 ppm (0–10 ppm), Overload Capacity 50 ppm
H₂S ChannelRange 0–200 ppm, Resolution <0.1 ppm, t₉₀ <25 s, Sensitivity 450–900 nA/ppm (at 20 ppm), Zero Current ±0.25 ppm, Linearity Error ±5 ppm (0–20 ppm), Overload Capacity 200 ppm
Filtered Cross-Sensitivity SuppressionIntegrated high-capacity SO₂-specific filter eliminates interference from H₂S, NOₓ, and acidic gases
Operating Temperature–20 °C to +50 °C
Operating Humidity15–90 % RH (non-condensing)
Expected Lifetime≥24 months (typical field use)
ComplianceCE marked, RoHS compliant, meets IEC 60079-29-1 (Explosive Atmospheres – Gas Detectors)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelH2S-A1
Measurement Range0–100 ppm
Sensitivity550–900 nA/ppm
Response Time (t₉₀)<25 s
Linear Range0–20 ppm
Full-Scale Linearity Error±4 ppm
Overload Capacity500 ppm
Resolution<0.05 ppm
Dimensions20.2 × 16.5 mm
Operating Temperature−30 to +50 °C
Operating Humidity15–90 %RH (non-condensing)
Load Resistance10–47 Ω
Expected Service Life24 months
Storage Shelf Life6 months
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelVOC-B4
Detection PrincipleAmperometric 4-Electrode Electrochemistry
Target GasesVolatile Organic Compounds (e.g., ethanol), Carbon Monoxide (CO)
Response Time (t₉₀)<30 s
DimensionsØ32.3 × 16.5 mm
CO Range0–100 ppm (overload: 1000 ppm)
Ethanol Range0–2 ppm (overload: 5 ppm)
CO Sensitivity400–700 nA/ppm
Ethanol Sensitivity400–650 nA/ppm
Bias Voltage Options0 V, 0.1 V, 0.2 V, or 0.3 V
Operating Temperature–20 °C to +50 °C
Humidity Range15–90 % RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelHCN-D4
Measurement PrincipleAmperometric Electrochemistry
Range0–50 ppm
Sensitivity30–50 nA/ppm
Response Time (t₉₀)<50 s
Overload Capacity250 ppm
Resolution<0.3 ppm
Operating Temperature–20 to +50 °C
Operating Humidity15–90 % RH (non-condensing)
Load Resistance10–47 Ω
Expected Operational Lifetime12 months
Storage Life (unmounted, sealed)6 months
DimensionsØ14.5 × 8.3 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelETO-A1
Measurement PrincipleAmperometric Electrochemistry
Detection Range0–100 ppm
Sensitivity2000–3200 nA/ppm
Response Time (t90)<150 s
Linear Range0–40 ppm
Full-Scale Error±5–10 ppm
Overload Capacity200 ppm
Resolution<0.1 ppm
DimensionsØ20.2 × 16.5 mm
Operating Temperature−30 to +50 °C
Operating Humidity15–90 %RH (non-condensing)
Load Resistance10–47 Ω
Expected Service Life24 months
Storage Shelf Life6 months
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelO2-C3
Measurement Range0–30% O₂
Operating Life>3 years
DimensionsΦ20.3 × 23 mm
Output Current65–85 µA @ 22°C, 20.9% O₂
Response Time (t₉₀)<45 s
Linearity Error±0.6 ppm
Weight<18 g
Operating Temperature−30 to +55°C
Operating Pressure80–120 kPa
Relative Humidity Range5–95% RH (non-condensing)
Storage Stability6 months
Load Resistance47–100 Ω
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
Model3SP_O3_20
Detection Range0–20 ppm
Overload Limit50 ppm
Response Time (t₉₀)<30 s
Sensitivity−30 ±5 nA/ppm
Dimensions15 × 15 × 3.8 mm
Operating Temperature−30 to +50 °C
Storage Life≥12 months (unmounted, sealed)
ComplianceRoHS, REACH, CE-marked per EN 61000-6-3/6-4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelCO-D4
Measurement Range0–1000 ppm CO
Sensitivity30–48 nA/ppm
Response Time (t₉₀)<25 s
Linear Range±40 ppm
Overload Capacity2000 ppm
Resolution1.5 ppm
DimensionsØ14.5 × 8.3 mm
Operating Temperature−20 to +50 °C
Operating Humidity15–90 %RH (non-condensing)
Load Resistance10–47 Ω
Expected Operational Lifetime2 years
Storage Shelf Life6 months
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelNH3-AF
Overload200 ppm
Response Time (T90)<60 s
DimensionsØ20.2 × 16.5 mm
Detection Range0–100 ppm NH₃
Sensitivity20–40 nA/ppm
Operating Temperature−20 to +50 °C
Operating Humidity15–90 % RH (non-condensing)
Zero Current<±20 nA
Load Resistance10 Ω
Expected Lifetime>24 months (in air)
Storage Life6 months (refrigerated, unopened)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelIRC-AT
Measurement PrincipleNon-Dispersive Infrared (NDIR)
Range0–5000 ppm / 0–5% vol / 0–20% vol
Resolution25 ppm / 250 ppm / 0.4% vol
Accuracy±1.5% FS / ±2.5% FS (depending on range)
Response Time (t₉₀)<40 s
Operating Temperature−20 °C to +50 °C
Expected Service Life>5 years
DimensionsØ20.0 × 16.5 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelH2-AF
Sensitivity10–25 nA/ppm
Overload Limit5000 ppm
Response Time (t₉₀)<100 s
Detection Range0–2000 ppm H₂
DimensionsØ20.2 × 16.5 mm
Sensor TypeThree-Electrode Electrochemical
Operating Temperature−20 °C to +50 °C
Operating Humidity15–90 % RH (non-condensing)
Expected Lifetime≥24 months (in air)
Zero Current<±5 nA
Baseline Stability<2 nA/week
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATEQ
ModelF6900-EC
OriginFrance
TypeVacuum Decay Leak Detection System
ComplianceASTM F2338-09
Internal VolumeMinimized Dead Volume
Power Supply100–240 VAC, 50 W
Drive Air Pressure400–600 kPa
Test Air Pressure+1–2 bar above test pressure
Air QualityISO 8573-1 Class 4 or better
Operating Temperature10–45 °C
Storage Temperature0–60 °C
HMIColor TFT Display with Intuitive Menu Navigation
Optional AccessoriesMicro-flowmeter, Custom Vial Test Chamber, Certified Leak Standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATEQ
ModelF5800-MR
OriginFrance
Measurement PrincipleVacuum Decay
ComplianceASTM F2338-09, FDA 21 CFR Part 11 (data integrity), ISO 8573-1 (air quality)
Test Volume<7 mL
Sensitivity≥0.02 cc/min (equivalent to ~1.5 µm equivalent leak diameter)
Operating Temperature10–45 °C
Power Supply100–240 VAC, 50 W
Dimensions (W×H×D)450 × 150 × 356 mm
Weight20 kg
DisplayColor touchscreen HMI
Pressure SensorsDual high-stability absolute pressure sensors
Data TraceabilityAudit trail, electronic signatures, method versioning
Validation SupportIQ/OQ/PQ documentation package, 3Q validation-ready
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelLFO2-A4
Measurement Range0–30% O₂
Operating Lifetime≥5 years
DimensionsØ20.3 × 16.5 mm
Output Current80–130 µA @ 20.9% O₂
Response Time (t₉₀)<17 s (20.9% → 0% O₂)
Linearity Error<0.1% O₂ at 10% O₂
Weight<6 g
Operating Temperature−30 to +50 °C
Pressure Range80–120 kPa
Humidity Range5–95% RH (non-condensing)
Storage Life6 months at 3–20 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelO2-A2
Measurement Range0–30% O₂ (v/v)
Operating Life>24 months to 85% of initial output
DimensionsØ20.3 × 16.8 mm
Output Current80–120 µA @ 22°C, 20.9% O₂
Response Time (t₉₀)<15 s (20.9% → 0% O₂, 47 Ω load)
Linearity Error<±0.6 ppm (full scale, zero & 400 ppm points)
Weight<16 g
Operating Temperature−30 to +55 °C
Pressure Range80–120 kPa
Relative Humidity5–95% RH (non-condensing)
Storage Duration6 months at 3–20 °C
Load Resistance47–100 Ω
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
Model3SP_SO2_20
Measurement Range0–20 ppm
Overload Capacity50 ppm
Response Time (t₉₀)<30 s
Sensitivity30 ± 5 nA/ppm
Dimensions15 × 15 × 3.8 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
Model3SP_H2S_50
Measurement Range0–50 ppm
Overload Capacity100 ppm
Response Time (t₉₀)<30 s
Dimensions15 × 15 × 3.8 mm
Sensitivity250 ± 50 nA/ppm
Operating Temperature−30 to +50 °C
Operating Humidity15–90 % RH (non-condensing)
Zero Current<±5 nA
Long-Term Drift<2 %/month (typical)
Expected Service Life≥24 months (in clean air, 23 °C, 50 % RH)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelSO2-AE
Detection Range0–2,000 ppm
Overload Capacity10,000 ppm
Response Time (t90)<33 s
Sensitivity55–80 nA/ppm
Resolution<1.5 ppm
DimensionsØ20.2 × 16.5 mm
Sensor TypeThree-electrode electrochemical gas sensor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelB4 Series
Detection Limit<10 ppb
Operating PrincipleAmperometric Electrochemistry with Auxiliary Electrode Compensation
Electrode Configuration4-Electrode (Working, Counter, Reference, Auxiliary)
Typical Response Time (t90)<30 s
Zero Current CompensationYes
Interference RejectionEnhanced via Auxiliary Electrode
Application EnvironmentAmbient Air, Indoor Air, Stack Emissions, Portable & Fixed Monitoring Systems
Compliance ContextDesigned for use in systems compliant with EN 14625, ISO 12039, and EPA Method IO-3.2 (for ambient O₃, NO₂, SO₂, H₂S, CO)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphasense (UK)
OriginUnited Kingdom
ModelHCN-B1
Measurement PrincipleAmperometric Electrochemistry
Detection Range0–100 ppm
Sensitivity65–140 nA/ppm
Response Time (t₉₀)<120 s
Linearity Range0–40 ppm (full-scale linearity error ≤ ±5% of reading in 0–4 ppm range)
Overload Capacity200 ppm
Resolution<0.05 ppm
DimensionsØ32.3 × 16.5 mm
Operating Temperature−30 to +50 °C
Operating Humidity15–90 % RH (non-condensing)
Load Resistance10–33 Ω
Expected Operational Lifetime12 months (typical, under standard ambient conditions)
Storage Shelf Life6 months (at 20 °C, sealed in original packaging)