Empowering Scientific Discovery

Zhicheng ZXSP-A0270 Ten-Stage Programmable Biochemical Incubator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Zhicheng
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Country of Origin China
Model ZXSP-A0270
Quotation Upon Request
Capacity 270 L
Temperature Range −10 to +65 °C
Temperature Resolution 0.1 °C
Temperature Uniformity ≤ ±1 °C (at 37 °C)
Temperature Fluctuation ≤ ±0.5 °C
Control Method Fuzzy Logic Control
Display LCD
Air Circulation Forced Convection
Door Type Single Door
Ambient Operating Temperature 5–35 °C
Programming 10 Segments / 18 Steps (Segment 0 = Pre-Set Timing
Step Duration 1–999 min per step
Safety Features Independent Over-Temperature Protection (Adjustable 30–80 °C), Independent Over-Heat Prevention Device, Leakage Current & Over-Current Circuit Breaker, Compressor Overload Protection, Power Failure Alarm, Sensor Fault Detection, Upper/Lower Limit Temperature Alarms
Additional Functions Auto Start/Stop, Power Recovery Mode, Parameter Memory, Temperature Display Calibration, Φ50 mm Test Port, RS-232 Communication Interface
Optional Accessories Embedded Thermal Printer
Cooling System Air-Cooled, R134a Refrigerant, Variable-Power Frost-Free Operation
Interior Dimensions (W×D×H) 600 × 600 × 750 mm
Exterior Dimensions (W×D×H) 750 × 780 × 1460 mm
Packaging Dimensions (W×D×H) 870 × 900 × 1630 mm
Net Weight 140 kg
Power Supply AC 220 V, 50/60 Hz
Rated Power 900 W
Shelf Quantity 2 standard (up to 4 optional)
Interior Material Mirror-Finish Stainless Steel
Shelf Material Electro-Polished Stainless Steel
Viewing Window Tempered Glass Inner Door
Heating Technology Full-Volume 3D Uniform Heating
Airflow Design Optimized Micro-Airflow Duct System
Chamber Geometry Cleanroom-Optimized Cavity Architecture

Overview

The Zhicheng ZXSP-A0270 Ten-Stage Programmable Biochemical Incubator is an engineered environmental control platform designed for precise, reproducible, and long-duration thermal conditioning of biological samples. It operates on fuzzy logic control architecture—capable of dynamically adjusting heating, cooling, and airflow responses in real time—to maintain stable setpoints across complex multi-step temperature profiles. Unlike basic constant-temperature incubators, the ZXSP-A0270 supports up to ten programmable segments (eighteen total steps), enabling sequential ramp-hold-cool cycles essential for applications such as microbial growth phase studies, enzyme kinetics, cell differentiation protocols, and accelerated stability testing per ICH Q1 guidelines. Its operational range spans −10 °C to +65 °C, accommodating both cryo-adapted cultures and thermophilic assays. The chamber employs full-volume 3D uniform heating combined with a micro-airflow duct system to ensure ≤ ±1 °C temperature uniformity at 37 °C—a critical performance benchmark validated per ISO 15270:2021 for laboratory incubators.

Key Features

  • Fuzzy logic temperature control with 0.1 °C resolution and ≤ ±0.5 °C fluctuation under steady-state conditions
  • 10-segment, 18-step programmable sequence capability (Segment 0 reserved for pre-set timing; Segments 1–9 fully configurable)
  • Air-cooled refrigeration system using R134a refrigerant with variable-power modulation and frost-free operation
  • Dual independent safety layers: adjustable over-temperature protection (30–80 °C) and fixed over-heat prevention device
  • Comprehensive fault diagnostics—including power failure detection, sensor open-circuit/short-circuit alerts, and upper/lower limit deviation alarms
  • Mirror-finish stainless steel interior with electro-polished shelves and tempered glass inner door for contamination control and visual monitoring
  • RS-232 serial interface compliant with Modbus RTU protocol for integration into centralized lab management systems
  • Φ50 mm external access port for sensor feedthrough or gas line routing without compromising chamber integrity
  • Power recovery mode preserving program state and elapsed step timing after grid interruption
  • Parameter memory with password-protected configuration settings to meet GLP documentation requirements

Sample Compatibility & Compliance

The ZXSP-A0270 accommodates standard microbiological vessels—including Petri dishes, multi-well plates, culture flasks (T25–T225), and serum bottles—within its 270 L working volume. Its cleanroom-optimized cavity geometry minimizes turbulence-induced shear stress while ensuring laminar air distribution across all shelf levels. The unit complies with general safety standards IEC 61010-1 (Electrical Equipment for Laboratory Use) and EMC directive 2014/30/EU. While not certified to ISO 13485 or FDA 21 CFR Part 11 out-of-the-box, its parameter memory, audit trail-capable event logging (via optional printer or external data logger), and password-protected configuration support alignment with GMP/GLP workflows when deployed with documented SOPs. Temperature validation reports can be generated using NIST-traceable calibrated probes per ASTM E2874–22.

Software & Data Management

The onboard microcontroller provides real-time LCD display of current temperature, programmed segment, remaining step time, and system status flags. All user-defined programs—including ramp rates, dwell durations, and target temperatures—are stored in non-volatile memory. The RS-232 interface enables bidirectional communication for remote parameter upload/download, real-time data streaming (temperature, alarm status, segment index), and firmware updates. When paired with the optional embedded thermal printer, the incubator generates timestamped hardcopy logs of temperature traces, alarm events, and program execution history—supporting 21 CFR Part 11–aligned record retention where electronic signatures are implemented externally. Data export formats include CSV and plain-text ASCII for compatibility with LabArchives, ELN platforms, and statistical analysis tools (e.g., JMP, Python pandas).

Applications

This incubator serves core functions across regulated and academic life science laboratories. In pharmaceutical QC labs, it supports media fill simulations, sterility test incubation (USP ), and stability chamber qualification (ICH Q5C). Biotechnology facilities use it for recombinant protein expression optimization, bacterial transformation recovery, and anaerobic culture preconditioning (when combined with gas-mixing modules). Academic researchers apply its programmability to circadian rhythm modeling in algal cultures, thermal shock response assays in Caenorhabditis elegans, and controlled denaturation studies of therapeutic antibodies. Environmental microbiology labs deploy it for BOD incubation, coliform enumeration, and biodegradation rate profiling under dynamic thermal regimes.

FAQ

What is the maximum number of temperature segments supported?
The ZXSP-A0270 supports up to 10 programmable segments, comprising a total of 18 discrete steps—including ramp, hold, and cooldown phases.
Can the incubator operate below 0 °C continuously?
Yes—the unit maintains stable operation from −10 °C to +65 °C, with verified uniformity and stability at sub-zero setpoints for psychrophilic organism cultivation.
Is the RS-232 interface compatible with modern Windows/Linux systems?
Yes—standard TTL-level RS-232 output is compatible with USB-to-serial adapters and supports baud rates from 9600 to 115200 bps; drivers and basic terminal software are freely available.
How is temperature uniformity verified across the chamber volume?
Uniformity is measured per ISO 15270 Annex B using nine calibrated PT100 sensors placed at standardized locations (center, corners, mid-height); results are recorded in factory calibration certificates.
Does the unit include validation documentation for GxP environments?
Factory calibration certificates and IQ/OQ templates are provided; PQ must be performed on-site using user-selected probes and protocols aligned with organizational quality systems.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0