Empowering Scientific Discovery

Chuanyi CYWB-10 High-Throughput Microwave Digestion System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Chuanyi Instruments (Hangzhou Chuanyi Electronic Co., Ltd.)
Origin Zhejiang, China
Manufacturer Type OEM/ODM Manufacturer
Country of Origin China
Model CYWB-10
Sample Capacity 10 vessels per run
Max Temperature 190 °C
Temperature Control Stability Non-pulsed continuous microwave frequency modulation
Max Pressure 1500 psi (10.34 MPa)
Cavity Volume 52 L
Cavity Material 316L stainless steel with 6-layer PTFE coating
Power Supply 220–240 VAC, 50/60 Hz, 15 A
Microwave Frequency 2450 MHz
Output Power 0–1600 W, continuously adjustable
Cooling Airflow ≥5 m³/min
Display 8-inch TFT-LED touchscreen (800×480)
Temp Sensing Contact-type Pt100 RTD (±0.5 °C accuracy)
Pressure Sensing Non-contact piezoelectric sensor (0.01 MPa resolution)
Vessel Material PEEK outer vessel + PTFE inner liner
Vessel Volume 100 mL
Rotation 360° continuous unidirectional rotation
Safety Features Auto-locking buffered anti-explosion door, dual-safety burst disc (ceramic-clamped), real-time pressure/temperature cutoff, electromagnetic leakage <5 mW/cm² (GB 10436-2008 compliant)

Overview

The Chuanyi CYWB-10 High-Throughput Microwave Digestion System is a fully enclosed, pressurized sample preparation instrument engineered for rapid, reproducible, and trace-metal-safe acid digestion of solid and semi-solid matrices. It operates on the principle of dielectric heating—where microwave energy (2450 MHz) couples directly with polar molecules (e.g., HNO₃, HCl, HF) to generate uniform volumetric heating within sealed reaction vessels. This enables controlled thermal decomposition under elevated temperature (up to 190 °C) and pressure (up to 1500 psi / 10.34 MPa), significantly accelerating digestion kinetics while minimizing analyte loss, contamination, or volatilization. Designed for laboratories requiring regulatory-compliant sample preparation—including those adhering to EPA Method 3051A/3052, ISO 11466, ASTM D5511, and GB/T 5009 series—the CYWB-10 delivers deterministic performance in environmental monitoring, food safety testing, clinical toxicology, geological analysis, and pharmaceutical QC workflows.

Key Features

  • Non-pulsed, continuously variable-frequency microwave generation ensures stable power delivery, reduced thermal stress on magnetron, and superior field homogeneity across the 52 L cavity.
  • 316L stainless steel cavity with six-layer PTFE corrosion-resistant coating withstands aggressive reagent vapors (e.g., HF, aqua regia) and repeated thermal cycling.
  • Self-locking buffered anti-explosion door incorporates mechanical energy-dissipating hinges and lateral pressure relief geometry—certified to contain overpressure events without structural compromise or operator exposure.
  • Dual independent control loops: contact-based Pt100 RTD for precise temperature monitoring (±0.5 °C), and non-contact piezoelectric transducers for high-fidelity pressure tracking (0.01 MPa resolution).
  • 360° continuous unidirectional rotation of the turntable ensures identical microwave coupling for all 10 vessels—eliminating positional bias and enhancing inter-vial precision (RSD < 3% for replicate digestions).
  • Real-time graphical display of temperature/pressure profiles on an 8-inch industrial-grade touchscreen; data logging supports timestamped export in CSV format for audit trail compliance.
  • Ceramic-clamped safety burst discs provide fail-safe pressure release at pre-calibrated thresholds—designed to rupture before PEEK/PTFE vessel deformation, preventing catastrophic failure.

Sample Compatibility & Compliance

The CYWB-10 accommodates up to ten 100 mL high-pressure digestion vessels per batch, each constructed from aerospace-grade PEEK polymer (outer jacket) and ultra-pure PTFE (inner liner), ensuring compatibility with concentrated nitric, hydrochloric, hydrofluoric, and perchloric acids. Vessels meet ISO 17025 traceability requirements for material certification and are validated for use in GLP and GMP environments. The system complies with national electromagnetic safety standards (GB 10436-2008), and its hardware architecture supports 21 CFR Part 11–ready software configurations when integrated with validated LIMS or ELN platforms. All pressure and temperature sensors undergo annual factory calibration traceable to NIM (National Institute of Metrology, China).

Software & Data Management

The embedded control firmware provides full parameter programmability—including ramp rate, hold time, maximum temperature/pressure limits, and power modulation profiles—for method development and SOP execution. All operational data (time-stamped T/P curves, power output, rotation status, fault logs) are stored locally and exportable via USB interface. Optional Ethernet connectivity enables remote monitoring and integration into centralized laboratory informatics systems. Audit trails include user ID, method name, start/stop timestamps, and any deviation alerts—supporting FDA- and CNAS-mandated documentation for method validation and quality audits.

Applications

  • Environmental: Total metal determination in soils, sediments, sludge, and airborne particulates (EPA 3051A, 3052, ISO 11466).
  • Food & Agriculture: Heavy metal screening in cereals, dairy, seafood, and infant formula (GB 5009.12, GB 5009.15).
  • Pharmaceuticals: Residual catalyst analysis in active pharmaceutical ingredients (USP <232>/<233>).
  • Clinical & Forensic: Trace element profiling in hair, blood, and tissue samples (CLIA, CAP guidelines).
  • Geological & Mining: Silicate rock dissolution for ICP-MS/OES multi-element quantification (ASTM D5511, ISO 13877).

FAQ

What safety certifications does the CYWB-10 hold?

It conforms to GB 10436-2008 for microwave radiation leakage (<5 mW/cm²), and its mechanical safety design aligns with EN 61000-3-2 and IEC 61010-1 for laboratory equipment.
Can the system be validated for GLP compliance?

Yes—when paired with documented IQ/OQ protocols and calibrated reference standards, the CYWB-10 supports full GLP validation including temperature uniformity mapping, pressure sensor linearity verification, and system suitability testing.
Is remote operation or network integration supported?

Standard USB data export is included; optional Ethernet module enables TCP/IP communication for SCADA or LIMS integration (custom API available upon request).
What maintenance intervals are recommended?

Magnetron output verification every 12 months; cavity coating inspection and door gasket replacement every 24 months; pressure sensor recalibration annually or after 500 cycles.
Are consumables supplied with traceable certificates of analysis?

All PTFE liners and PEEK vessels ship with lot-specific CoA confirming elemental impurity levels (<0.1 ppb Cr, Ni, Cu, Pb, Cd, As) and dimensional tolerance compliance.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0