CZGY CX-001 Aluminum Block Heater

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand CZGY
Origin Jiangsu, China
Manufacturer Type Direct Manufacturer
Model CX-001
Temperature Range Ambient to 300 °C
Temperature Accuracy ±0.5 °C
Temperature Stability ≤1 °C
Heating Blocks 7-position (customizable well diameter & depth)
Heating Power 300 W × 6 zones
Control System Digital PID with LCD dual-line display
Sensor PT100 platinum resistance thermometer
Timer Range 0–9999 minutes/hours
Compliance Designed for GLP-compliant thermal processing of organic reference standards and polymer intermediates

Overview

The CZGY CX-001 Aluminum Block Heater is a precision-engineered dry bath instrument designed for controlled, uniform thermal treatment of small-volume samples in sealed or open-format glassware—particularly critical for colorimetric and thermal stability assessments of high-melting-point organic compounds. Unlike conventional heating mantles or oil baths, this unit employs a solid aluminum heating block with optimized thermal mass and conductivity, enabling rapid equilibration and minimal spatial temperature gradient across all seven wells. Its core operational principle relies on resistive heating of the aluminum block, regulated via closed-loop feedback from a calibrated PT100 sensor embedded directly into the block matrix. This architecture ensures traceable, reproducible temperature control within ±0.5 °C over the full 20–300 °C operating range—essential for standardized testing of phthalic anhydride, maleic anhydride, phenol, and plasticizer derivatives per ASTM D1209 (APHA color), ISO 6271 (melting point determination), and USP (color of liquids). The heater is not intended for digestion under pressure or reactive chemistry; it serves strictly as a thermostatic platform for melt-phase observation, crystallization endpoint detection, and pre-conditioning prior to spectrophotometric analysis.

Key Features

  • Seven independently accessible, vertically aligned aluminum wells—each configurable in diameter (standard: 16 mm) and depth (standard: 75 mm) to accommodate standard colorimeter tubes, melting point capillaries, or custom sample vials.
  • Dual-line LCD interface displaying setpoint temperature and real-time block temperature simultaneously, with intuitive keypad navigation and non-volatile parameter memory.
  • High-stability PID algorithm with adaptive tuning, coupled to a solid-state relay output stage for zero-contact switching and extended service life—eliminating mechanical relay wear associated with legacy heating sleeves.
  • PT100 Class A sensor mounted at the thermal center of the block, providing NIST-traceable calibration capability and long-term drift compensation (<0.1 °C/year typical).
  • Modular 300 W × 6-zone heating configuration ensures uniform power distribution and fault isolation—should one zone degrade, remaining zones maintain operational continuity without thermal cascade.
  • Timer function supports both minute- and hour-based operation (0–9999 units), with auto-shutdown and audible alert—critical for unattended crystallization endpoint monitoring in quality control labs.

Sample Compatibility & Compliance

The CX-001 is validated for use with borosilicate glass test tubes (e.g., 16×100 mm, 18×150 mm), sealed capillary tubes, and quartz cuvettes up to 300 °C. It complies with fundamental requirements of ISO/IEC 17025:2017 for equipment used in accredited testing laboratories, including documented calibration procedures, uncertainty budgets for temperature measurement, and maintenance logs. While not certified to IEC 61000-4 electromagnetic immunity standards out-of-box, its low EMI design meets EN 61326-1 for laboratory instrumentation. The unit supports audit-ready workflows under FDA 21 CFR Part 11 when integrated with compliant LIMS software—timer logs, temperature setpoints, and run durations are exportable as CSV for electronic record retention. All materials in contact with the heating block (anodized aluminum, stainless steel fasteners) conform to USP Class VI biocompatibility and RoHS Directive 2011/65/EU.

Software & Data Management

The CX-001 operates as a standalone instrument with no proprietary software dependency. All operational parameters—including setpoint, timer value, PID coefficients, and alarm thresholds—are configured locally via the front-panel interface. Temperature data is not streamed in real time; however, the dual-line LCD provides continuous visual verification of thermal state. For laboratories requiring digital integration, optional RS-232 or USB-to-serial adapters enable ASCII command protocol communication (e.g., “READ_TEMP”, “SET_SP=250.0”) compatible with LabVIEW, Python pySerial, or custom SCADA systems. Exported logs include timestamped temperature snapshots at user-defined intervals (1–60 s), supporting statistical process control (SPC) charting and trend analysis per ISO 9001 clause 8.5.2.

Applications

  • Determination of APHA/Pt-Co color index for molten phthalic anhydride and maleic anhydride per ASTM D1209 and GB/T 12009.3.
  • Thermal stability assessment of plasticizers (e.g., DEHP, DINP) during heat aging protocols defined in ISO 188 and ASTM D5722.
  • Crystallization point measurement of phenolic compounds using differential thermal analysis (DTA)-compatible tube geometry.
  • Pre-heating and hold-stage conditioning of reference standards prior to HPLC or GC injection—ensuring consistent vapor-phase introduction kinetics.
  • Controlled melt-phase homogenization of polymer additives prior to rheological characterization or FTIR sampling.

FAQ

What is the maximum recommended operating temperature for prolonged use?
Continuous operation at 300 °C is rated for ≤2 hours per cycle. For routine QC work, optimal longevity is achieved at ≤260 °C with duty cycles below 75%.
Can the well dimensions be modified after purchase?
Yes—CZGY offers post-purchase re-boring services for existing blocks; lead time is 10 business days. Custom inserts (stainless steel or ceramic-lined) are available for corrosive sample matrices.
Is calibration certification included with shipment?
A factory-issued calibration report (traceable to NIM China) is provided with each unit. On-site recalibration services are available through authorized CZGY service partners in EU and North America.
Does the unit support external temperature probes for sample-in-tube monitoring?
No—the CX-001 controls only block temperature. For direct sample temperature validation, users must employ separate calibrated immersion probes (e.g., Fluke 54II) inserted into representative tubes during method development.
How is thermal uniformity verified across the 7 wells?
Uniformity is tested per ISO 17025 Annex A.3 using 7 calibrated PT100 probes placed at identical radial and axial positions. Typical deviation is ≤0.8 °C at 200 °C (n=5 runs).