Empowering Scientific Discovery

Aerospace ZJC-100KV Voltage Breakdown Tester / Dielectric Strength Tester

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Aerospace
Origin Beijing, China
Model ZJC-100KV
Breakdown Voltage Range 0–100 kV (AC/DC)
Voltage Accuracy ≤1%
Test Media Air or Insulating Oil
Electrode Options 25 mm, 75 mm, 6 mm (spherical, disk, rod configurations)
Power Capacity 5 kVA or 10 kVA
Rise Rate 10 V/s – 5 kV/s (continuously adjustable)
Safety Protection 9-level interlocked protection system
Compliance GB/T 1408.1–2006, GB/T 1695–2005, GB/T 3333–1999, ASTM D149, ASTM D3755, IEC 60243-1
Dimensions (Standard) 700 × 800 × 1300 mm (L×W×H), 100 kg
Dimensions (Large) 1900 × 1300 × 1700 mm (L×W×H), 200 kg
Input Voltage 220 V AC, 50/60 Hz
Maximum Hold Time 8 hours
Data Interface Optical-isolated acquisition, Bluetooth remote control
Software Windows-based test management with real-time curve plotting, audit trail, export to Excel/Word, user access control, and GLP-compliant reporting

Overview

The Aerospace ZJC-100KV Voltage Breakdown Tester is a precision-engineered dielectric strength testing system designed for quantitative evaluation of electrical insulation integrity in solid and semi-rigid materials. It operates on the fundamental principle of controlled voltage stress application—either AC (48–62 Hz) or DC—to induce dielectric breakdown under standardized conditions. The instrument conforms rigorously to international test methodologies including GB/T 1408.1–2006 (equivalent to IEC 60243-1), ASTM D149 (Standard Test Method for Dielectric Breakdown Voltage of Solid Electrical Insulating Materials at Commercial Power Frequencies), and ASTM D3755 (for polymeric films). Its core architecture integrates a high-stability transformer bank, optically isolated data acquisition, and PLC-synchronized servo-controlled voltage ramping to ensure metrological traceability and repeatability across laboratories conducting QC, R&D, or certification testing.

Key Features

  • Full-range programmable voltage output: 0–100 kV AC/DC with ≤1% measurement uncertainty per IEC 61000-4-30 Class A calibration reference.
  • Multi-mode voltage ramping: Continuous linear rise, stepwise incremental ramp, and fixed-voltage hold (up to 8 hours) — all configurable via software with sub-second timing resolution.
  • Optically isolated signal path eliminates electromagnetic interference during high-voltage transients, ensuring stable leakage current monitoring down to 1 µA.
  • Nine-tier hardware and firmware safety interlock system: Includes overvoltage cutoff, overcurrent interruption (<0.1 s response), door position sensing, zero-voltage reset logic, post-test electromagnetic discharge, independent grounding, and software-initiated emergency shutdown.
  • Modular electrode platform supporting standardized geometries per ASTM D149 and GB/T 1408: 25 mm diameter disc electrodes (for thin films), 75 mm electrodes (for bulk plastics/rubbers), and 6 mm spherical tips (for localized stress analysis).
  • Vertical cabinet design with integrated castor mobility — optimized for ISO 17025-accredited lab environments where floor space and reconfiguration flexibility are critical.
  • Bluetooth-enabled remote operation allows safe distance control during high-energy tests, reducing operator exposure risk without compromising real-time parameter adjustment.

Sample Compatibility & Compliance

The ZJC-100KV accommodates a broad spectrum of insulating materials compliant with ISO/IEC 17025 and GLP requirements. Validated substrates include thermoplastic and thermoset polymers (e.g., PE, PP, epoxy resins), elastomers (silicone, EPDM, neoprene), ceramic tiles and substrates, glass plates, laminated composites (G10/FR4), paper-based dielectrics (capacitor paper, cable wrapping), varnish-coated wires, and molded insulators. Testing may be conducted in ambient air or dielectric oil (e.g., ASTM D877-compliant mineral oil), enabling comparative assessment of surface vs. bulk breakdown mechanisms. All operational modes satisfy mandatory clauses in GB/T 1408.1 (Clause 6.2: voltage application methods), ASTM D149 (Section 7.3: rate-of-rise tolerances), and USP for pharmaceutical packaging qualification where electrical barrier performance is specified.

Software & Data Management

The proprietary Windows-based test suite provides full audit-trail capability aligned with FDA 21 CFR Part 11 requirements. Each test session logs operator ID, timestamp, environmental conditions (optional external sensor integration), raw voltage/current waveforms, breakdown event markers, and final calculated dielectric strength (kV/mm). Real-time overlay plotting enables immediate cross-sample comparison; historical datasets support statistical process control (SPC) trending. Reports are exportable in PDF, Excel (.xlsx), and Word (.docx) formats with customizable templates meeting ISO/IEC 17025 clause 7.8.2 documentation mandates. Role-based access control restricts configuration changes to authorized personnel only; all modifications are time-stamped and logged in an immutable binary journal file.

Applications

This tester serves critical functions across multiple regulated sectors: incoming material verification for wire & cable manufacturers (per UL 1581, ICEA T-28-533); qualification of encapsulation compounds in power electronics (IEC 60664-1); failure analysis of PCB substrates under HV stress; development of medical device insulation barriers (IEC 60601-1 Clause 8.8.3); and validation of aerospace-grade polymer composites per SAE AMS3675. It further supports academic research into Townsend discharge thresholds, partial discharge inception voltages, and time-lag statistics in polymeric dielectrics under accelerated aging protocols.

FAQ

What standards does the ZJC-100KV directly support out-of-the-box?
GB/T 1408.1–2006, GB/T 1695–2005, ASTM D149, ASTM D3755, IEC 60243-1, and ISO 2309 — with preloaded test templates and pass/fail logic embedded in firmware.
Can the system perform both short-term breakdown and long-duration withstand testing?
Yes — it supports continuous voltage hold up to 8 hours with ±0.5% regulation stability and automatic termination upon leakage current exceedance.
Is third-party calibration and certification available?
Calibration certificates traceable to NIM (China National Institute of Metrology) or CNAS-accredited labs (e.g., China Academy of Space Technology Test Center No. 514, China Electronics Standardization Institute No. 304) are optionally provided with documented uncertainty budgets.
How is data integrity ensured during high-noise HV switching events?
All analog inputs use galvanically isolated 24-bit sigma-delta ADCs with anti-alias filtering; digital control signals employ fiber-optic links between PLC and HV module to eliminate ground-loop coupling.
Does the software meet regulatory requirements for electronic records?
Yes — it implements ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available) and includes electronic signatures, audit trails, and 21 CFR Part 11-compliant user authentication layers.