AIRTECH BSC-04IIA2 Series Class II Type A2 Biological Safety Cabinet
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | BSC-1004IIA2 / BSC-1304IIA2 / BSC-1604IIA2 / BSC-1804IIA2 |
| External Dimensions (L×W×H, mm) | 1200/1500/1800/2000 × 795 × 2050 |
| Internal Work Area Dimensions (L×W×H, mm) | 1004/1304/1604/1804 × 630 × 630 |
| ULPA Filter Efficiency | ≥99.9995% @ 0.12 µm |
| Cabinet Classification | NSF/ANSI 49–2022 Class II, Type A2 |
| Airflow Velocity (Inflow/Downflow) | 0.50–0.55 m/s / 0.25–0.30 m/s (typical, per model and certification) |
| Filter Type | Dual ULPA (Supply & Exhaust) with Leak-Proof Sealing Technology |
| Power Supply | 220 V AC, 50 Hz |
| Motor Type | Brushless DC Constant-Flow Fan |
Overview
The AIRTECH BSC-04IIA2 Series is a certified NSF/ANSI 49–2022 Class II, Type A2 biological safety cabinet engineered for simultaneous personnel, product, and environmental protection in microbiological, pharmaceutical, and clinical laboratory applications. It operates on the principle of laminar airflow generated by dual ULPA-filtered air streams: downward laminar flow (≥0.25 m/s) protects the work surface from airborne contamination, while inward inflow (≥0.50 m/s at the sash opening) safeguards the operator from aerosols generated during procedures. Recirculated air—approximately 70% of total airflow—is filtered through a supply ULPA filter before reintroduction into the work area; the remaining 30% is exhausted via dedicated ducting after passing through a second ULPA filter. This configuration ensures ISO Class 4 (equivalent to Federal Standard 209E Class 10) cleanliness within the work chamber while maintaining safe containment of low-to-moderate risk biological agents (BSL-1 to BSL-2).
Key Features
- Brushless DC constant-flow fan system delivering stable inflow and downflow velocities across the full operational life of the ULPA filters—even with up to 50% increase in filter resistance—ensuring ≤10% airflow deviation and consistent containment performance.
- Full-color high-resolution LCD control interface with real-time monitoring of fan status, filter pressure differential, sash position, airflow velocity, and remaining filter service life; configurable audible and visual alarms for sash deviation, airflow failure, or filter saturation.
- Full-height tempered glass sash with dual-position stop mechanism (fully open and working height), enabling complete interior access for cleaning; seamless stainless-steel interior surfaces with rounded corners and no exposed fasteners to eliminate microbial harborage zones.
- Removable, adjustable stainless-steel work surface with integrated lifting handles and support brackets for rapid decontamination and maintenance; two recessed GFCI-protected 120/220 V AC outlets per side and dual utility pass-through ports (water/gas) on both left and right walls for flexible integration with IV admixture systems or ancillary equipment.
- Power-loss memory function: automatically reverts to pre-interruption operating mode—including sash position, airflow setpoint, and alarm thresholds—upon restoration of mains power, supporting GLP-compliant continuity of critical workflows.
- ULPA filtration system utilizing low-boron, high-strength pleated media (HV Technologies, USA) with ultra-low initial pressure drop (≤250 Pa at rated flow) and extended service life; both supply and exhaust filters feature proprietary leak-tight gasketing and structural sealing compliant with IEST-RP-CC001.4 integrity test requirements.
Sample Compatibility & Compliance
The BSC-04IIA2 series supports routine handling of cell cultures, recombinant DNA constructs, diagnostic specimens, and non-volatile pharmaceutical compounds under BSL-2 conditions. It is validated for use with standard microbiological techniques including pipetting, centrifugation (with sealed rotors), and sterile transfer operations. All models are certified to NSF/ANSI 49–2022 and comply with ISO 14644-1 Class 4 (10) cleanroom requirements for the work area. The cabinet meets electromagnetic compatibility (EMC) standards per IEC 61326-1 and electrical safety requirements per IEC 61010-1. Optional documentation packages include Factory Acceptance Test (FAT) reports, filter integrity certificates (DOP/PAO scan data), and installation qualification (IQ) templates aligned with FDA 21 CFR Part 11 and EU Annex 11 expectations for regulated environments.
Software & Data Management
The embedded microcontroller firmware supports time-stamped event logging (sash movement, alarm triggers, filter runtime, power cycles) with export capability via USB port. Audit trail functionality records all parameter changes—including user ID (if integrated with facility LDAP), timestamp, and previous/updated values—meeting ALCOA+ principles for data integrity. No cloud connectivity is implemented; all data remains local to ensure compliance with institutional IT security policies and HIPAA/GDPR-aligned data sovereignty requirements. Optional RS-485 Modbus RTU interface enables integration with building management systems (BMS) or centralized lab monitoring platforms for remote status verification (not remote control).
Applications
- Compounding sterile preparations (CSPs) in hospital pharmacy IV admixture centers, adhering to USP and environmental controls.
- Handling of primary human cells, hybridomas, and lentiviral vectors in academic and biotech R&D laboratories.
- Quality control testing of sterile pharmaceutical products and medical devices under ISO 13485 and EU GMP Annex 1 frameworks.
- Diagnostic specimen processing in clinical microbiology labs performing culture-based identification and antimicrobial susceptibility testing.
- Teaching laboratories requiring robust, low-maintenance containment for undergraduate and graduate biosafety training modules.
FAQ
What regulatory certifications does the BSC-04IIA2 series hold?
NSF/ANSI 49–2022 Class II, Type A2 certification is standard for all models. Additional optional documentation includes ISO 14644-1 Class 4 verification reports and IEST-RP-CC001.4 filter integrity test records.
Can this cabinet be installed in a recirculating (nondedicated) exhaust configuration?
Yes—Type A2 cabinets may operate in either hard-ducted or thimble-connected (via canopy) modes. However, recirculation requires appropriate room air balance and makeup air capacity per ASHRAE 110 test protocol.
Is the ULPA filter replaceable in situ without tools?
Supply and exhaust ULPA filters are accessible from the rear service panel and designed for tool-free removal and replacement using quarter-turn locking mechanisms.
Does the unit support third-party calibration and validation services?
All models include standardized test ports and documentation required for third-party IQ/OQ/PQ execution by accredited service providers (e.g., certified to ISO/IEC 17025).
What is the expected service life of the ULPA filters under typical BSL-2 usage?
Based on continuous operation at nominal airflow and ambient particulate load, supply and exhaust ULPA filters typically achieve 5–7 years of service life, as indicated by real-time pressure differential monitoring and manufacturer’s lifetime algorithm.