Empowering Scientific Discovery

JAI NFL-700M Column Oven

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Key Brand: JAI
Origin Japan
Model NFL-700M, NFL-700L
Temperature Range (Ambient +10)°C to 99°C (NFL-700M), (Ambient +1)°C to 70°C (NFL-700L)
Max Column Capacity 4 × φ23×600 mm HPLC columns
Internal Dimensions 200W × 700H × 150D mm
External Dimensions 260W × 850H × 420D mm
Power Supply AC 100 V, 50/60 Hz, 5 A
Weight 25 kg (NFL-700M), 35 kg (NFL-700L)
THF Vapor Sensor 0.1% detection threshold
Compliance Designed for integration with JAIGEL GPC/SEC systems

Overview

The JAI NFL-700M Column Oven is a precision-engineered thermal management system designed specifically for high-performance liquid chromatography (HPLC), gel permeation chromatography (GPC), and size-exclusion chromatography (SEC) applications. It maintains stable, uniform column temperature under controlled ambient conditions—critical for reproducible retention time, improved peak resolution, and enhanced polymer characterization accuracy. Unlike generic incubators or heated enclosures, the NFL-700M employs a dual-zone forced-air circulation architecture with PID-controlled heating elements and insulated chamber walls to minimize axial and radial thermal gradients across the column bed. Its operational range extends from ambient +10°C to 99°C (NFL-700M) or ambient +1°C to 70°C (NFL-700L), accommodating both standard reversed-phase separations and low-temperature SEC analyses requiring sub-ambient stability via external chiller coupling (when used with compatible cooling modules). The oven’s vertical orientation and 700 mm internal height support full-length JAIGEL analytical and preparative columns—including φ23 mm × 600 mm guard-and-analytical column configurations—without compromising thermal homogeneity or accessibility for maintenance.

Key Features

  • Vertical column chamber with 700 mm internal height—optimized for full-length JAIGEL GPC columns and multi-column serial configurations
  • PID-regulated heating system delivering ±0.1°C temperature stability over time and ±0.3°C spatial uniformity across the column axis
  • Forced-air convection design with adjustable airflow velocity to suppress thermal stratification while minimizing mechanical vibration transmission to connected detectors
  • Integrated THF vapor sensor (0.1% detection threshold) for solvent compatibility monitoring in organic mobile phase environments
  • Front-access door with magnetic latch and silicone gasket seal to ensure thermal integrity during routine column swaps and system purging
  • Dual-model platform: NFL-700M for high-temperature operation up to 99°C; NFL-700L for extended low-temperature stability down to ambient +1°C
  • Compact footprint (260W × 850H × 420D mm) enabling benchtop integration adjacent to HPLC pumps, autosamplers, and differential refractometers

Sample Compatibility & Compliance

The NFL-700M is engineered for seamless integration into JAI’s modular GPC/SEC platforms, supporting all JAIGEL series columns (e.g., JAIGEL-1H, -2H, -3H, -4H) and compatible with third-party stainless-steel or PEEK-lined columns up to φ23 mm outer diameter and 600 mm length. Chamber geometry accommodates up to four parallel columns for multidimensional or heart-cutting configurations. All electrical components comply with JIS C 61010-1 safety standards for laboratory equipment. The unit meets electromagnetic compatibility requirements per JIS C 61326-1 and is constructed using flame-retardant ABS housing with UL94-V0 rating. While not certified as explosion-proof, its THF vapor sensing capability supports risk mitigation in solvent-rich environments per OSHA 1910.1200 (HCS) guidelines. No CE marking is applied; units are supplied for research use only and intended for installation within validated laboratory infrastructure meeting ISO/IEC 17025 environmental control provisions.

Software & Data Management

The NFL-700M operates as a standalone thermal controller with analog temperature setpoint input (0–5 V DC) and real-time analog output (0–5 V DC proportional to chamber temperature). It does not include embedded firmware, touchscreen interface, or network connectivity. Integration with chromatography data systems (CDS) such as Empower, Chromeleon, or LabSolutions requires external analog-to-digital signal conditioning and custom script-based logging via DAQ hardware. Temperature calibration traceability follows JAI’s internal metrology protocol, with factory-certified verification at three points (30°C, 60°C, 90°C) against NIST-traceable RTD references. Audit trail generation for temperature logs must be implemented externally through CDS or LIMS platforms compliant with FDA 21 CFR Part 11 when deployed in regulated GMP/GLP environments.

Applications

  • Gel permeation chromatography of synthetic polymers (PS, PMMA, PVC) where precise temperature control directly impacts hydrodynamic volume calibration and molecular weight distribution accuracy
  • High-temperature HPLC analysis of thermally labile biopolymers (e.g., cellulose derivatives, chitosan) requiring elevated eluent viscosity reduction without degradation
  • Method development for reversed-phase separations involving temperature-sensitive small molecules (e.g., enantiomers, isomers) where retention time window optimization depends on ±0.2°C thermal consistency
  • Long-term column conditioning protocols for silica-based stationary phases exposed to aqueous-organic gradients at elevated temperatures
  • Multi-detector SEC setups combining RI, UV, and light scattering detectors—where column oven thermal stability prevents baseline drift induced by detector temperature mismatch

FAQ

Can the NFL-700M be used with non-JAI columns?
Yes—provided column outer diameter does not exceed φ23 mm and total length remains ≤600 mm. Mechanical fit and thermal contact efficiency should be verified prior to method validation.
Is remote temperature monitoring supported?
No native digital interface exists; however, analog voltage outputs can be logged via external DAQ systems compatible with LabVIEW, Python (PyVISA), or MATLAB.
Does the unit support cooling below ambient temperature?
Not intrinsically—the NFL-700L model achieves ambient +1°C minimum. Active cooling requires integration with an external recirculating chiller connected to optional heat-exchange fittings (sold separately).
What maintenance is required for long-term thermal accuracy?
Annual verification of PID controller response and sensor calibration against certified reference thermometers is recommended. Air filter cleaning every six months ensures consistent airflow performance.
Is the THF sensor replaceable in the field?
Yes—the electrochemical THF sensor module is user-replaceable using standard Torx T10 tools; replacement part number is JAI-SNS-THF-01.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0