| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5100 |
| Application Scope | Solid, Liquid and Gas Samples |
| Combustion Technology | Dual-Mode High-Temperature Catalytic Combustion (950–1150 °C) |
| Detection Principle | UV-Fluorescence (S), Chemiluminescence (N), Microcoulometric Titration (Cl), IR Absorption (C) |
| Sample Throughput | Up to 120 samples/day (with auto-sampler) |
| Compliance | ASTM D5291, D3120, D4294, D5762, ISO 20846, ISO 14596, UOP 390, IP 287, EN ISO 14596 |
| Safety Features | Integrated self-diagnostic system, real-time parameter monitoring, carbon deposit prevention via FIRE sensor technology |
| Automation | Optional high-capacity autosampler (up to 120 positions), gas sampling module (for LPG, natural gas, refinery streams) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ML54T |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 52 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Stabilization Time | 2 s |
| Minimum Weight (USP <41>) | 120 mg |
| Minimum Weight (U=1%, k=2) | 12 mg |
| Calibration | FACT fully automatic internal calibration |
| Leveling System | LevelControl with on-screen guidance |
| Weighing Pan Dimensions | 90 mm diameter |
| Display | 4.5-inch full-color capacitive touchscreen |
| Connectivity | USB Host, USB Device, RS232, optional Bluetooth |
| Data Transfer | PC Direct mode (no driver or software required) |
| Housing Material | ABS/PC top cover with metal base |
| Environmental Protection | IP42-rated enclosure |
| Power Options | AC adapter or rechargeable Li-ion battery (up to 8 h operation) |
| Compliance | ISO/IEC 17025 traceable calibration records, USP <41> and <1251> compliant, GLP/GMP-ready audit trail (ISO Log), 21 CFR Part 11 compatible with optional software |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST Configuration 2 |
| Vessel Capacity | 2000 mL |
| Construction Material | Borosilicate Glass 3.3 |
| Operating Pressure Range | Up to 6 bar (gauge) / Vacuum down to 25 mbar abs |
| Jacketed Vessel | Yes (LR 2000.1) |
| Stirring Drive | EUROSTAR 200 control P4, high-torque digital motor |
| Stirrer Type | LR 2000.11 anchor impeller with flow-through orifices |
| Sealing Material | FFPM (perfluoroelastomer) for solvent and thermal resistance |
| Speed Control | Stepless electronic regulation (0–250 rpm), microprocessor-controlled speed stability under load |
| Torque Monitoring | Integrated relative torque display for real-time viscosity trend indication |
| Safety Features | Interlocked safety switch, pressure/vacuum-rated lid assembly |
| Compatibility | ULTRA-TURRAX® disperser, temperature probe, pH electrode, and auxiliary feed ports |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | G-L |
| Instrument Type | Palm-Sized Centrifuge |
| Speed Range | 0 / 800 – 15,700 rpm |
| Max RCF | 16,500 × g |
| Max Capacity | 12 × 1.5 / 2.0 mL tubes |
| Rotor Compatibility | Optional 0.4 / 0.5 mL microtubes and PCR strips |
| Timer Range | 20 s – 99 min 59 s (1 s increment) |
| Speed Accuracy | ±5% |
| Acceleration/Deceleration | Programmable |
| Safety Features | Automatic lid lock, imbalance detection, emergency stop, metal rotor cover |
| Rotor Exchange | Tool-free |
| Memory | 9 user-programmable protocols |
| Interface | USB for firmware updates |
| Ingress Protection | IP20 (DIN EN 60529) |
| Dimensions | 200 × 140 × 280 mm |
| Weight | 3.9 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | C-MAG HS 4 DIGITAL S025 |
| Instrument Type | Heating Magnetic Stirrer |
| Max. Stirring Volume | 5 L (H₂O) |
| Speed Range | 100–1500 rpm |
| Heating Temperature Range | 50–500 °C |
| Heating Power | 250 W |
| Plate Material | Ceramic |
| Plate Dimensions | 100 × 100 mm |
| Safety Cut-off | 550 °C |
| External Temp. Sensor Interface | PT1000 |
| Temp. Control Accuracy (with PT1000) | ±0.5 K |
| Display | Dual LCD (setpoint & actual temp.) |
| IP Rating | IP21 |
| Input Voltage | 230 V, 50/60 Hz |
| Weight | 3.566 kg |
| Dimensions (W×D×H) | 150 × 105 × 260 mm |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | RKG-00-Bo |
| Type | Electric Stirrer |
| Certification | ATEX 95 (Category 1G, Temperature Class T3) |
| Construction Material | 316L Stainless Steel (DIN 1.4404) |
| Speed Control | Continuously Variable Mechanical Adjustment |
| Application Scope | Low-to-medium viscosity free-flowing liquids in open or non-pressurized vessels |
| Compatible Accessories | Propeller, Turbine, Dissolver, Centrifugal, Paddle, and Anchor Impellers |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Model | V20S |
| Moisture Range | 10 ppm to 100% (w/w) |
| Accuracy | ±0.3% relative |
| Minimum Dispensing Volume | 1 µL |
| Compliance | ASTM E203, ISO 760, USP <921>, EP 2.5.12, GLP/GMP-ready |
| Software | titrando® with One Click™ workflow engine |
| Electrode Options | Membrane-free or membrane-separated generator electrodes |
| Solvent Management | Integrated Solvent Manager with LevelSens™ level monitoring |
| Sample Introduction | Direct addition, oven coupling (up to 300 °C), and headspace extraction |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Avanti JXN-26 |
| Instrument Type | Floor-standing centrifuge |
| Speed Range | Up to 26,000 rpm |
| Max RCF | 82,000 × g |
| Max Capacity | 6 L |
| Rotor Configuration | Fixed-angle rotors standard |
| Sample Class | Cells and bacteria |
| Dimensions (W×D×H) | 86 × 71 × 86 cm |
| Compliance | Designed for GLP/GMP-aligned workflows, 21 CFR Part 11–ready software architecture |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | lab disc meadow |
| Stirrer Type | Magnetic Stirrer |
| Max Stirring Volume (H₂O) | 0.8 L |
| Speed Range | 15–1500 rpm |
| IP Rating | IP65 |
| Operating Temperature Range | 5–40 °C |
| Relative Humidity Limit | 80 % |
| Input Voltage | 100–240 V AC, 50/60 Hz |
| Input Power | 5 W |
| Motor Output Power | 3 W |
| Max Stir Bar Length | 25 mm |
| Plate Material | Polyester Film |
| Plate Diameter | Ø100 mm |
| Dimensions (W × H × D) | 117 × 12 × 180 mm |
| Weight | 0.3 kg |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | Echo MS |
| Instrument Type | Ultra-High-Throughput Direct-Infusion Mass Spectrometry System |
| Application Scope | Universal Quantitative Bioanalysis |
| Regulatory Context | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11-compliant data management frameworks |
| Sample Introduction Method | Contactless Acoustic Droplet Ejection (ADE) coupled to triple quadrupole mass spectrometry |
| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Microscope Type | Upright |
| Eyepiece Configuration | Binocular |
| Objective Turret | Motorized 6-Position |
| Condenser | Automated High-Aperture (0.90 NA) with Position Memory |
| Illumination | Motorized Brightness Control per Objective |
| Ergonomic Features | Adjustable-Height Focus Knobs (Patent DE10340721), Symmetrical XY Stage, One-Hand Operation, ErgoStage with Ceramic Surface |
| Software Compatibility | Leica Application Suite (LAS) for Pathology & Cytology Imaging |
| Compliance | Designed for ISO 13485-aligned clinical laboratories, supports GLP/GMP documentation workflows via LAS audit trail and user access control |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HPD Handheld Powder Dispenser |
| Capacity Range | 100–200 g |
| Maximum Capacity | 100 g |
| Readability | 0.001 g (1 mg) |
| Repeatability | 1 mg |
| Instrument Type | Precision Powder Dispensing System |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WATO EX-35Vet |
| Instrument Type | Veterinary Anesthesia and Monitoring System |
| Display | 10.4-inch TFT high-resolution touchscreen |
| Ventilation Modes | Volume-Controlled (VCV), Pressure-Controlled (PCV), Pressure-Controlled Ventilation with Volume Guarantee (PCV-VG), Spontaneous Breathing Support |
| Minimum Tidal Volume | 5 mL |
| Gas Monitoring Options | EtCO₂, Oxygen (O₂), Nitrous Oxide (N₂O), Halogenated Anesthetics (e.g., Isoflurane, Sevoflurane) |
| Vaporizer | Precision V60 calibrated halogenated anesthetic vaporizer (CE & FDA cleared) |
| Breathing Circuit | Integrated dual-mode (rebreathing/non-rebreathing), tool-free soda lime canister replacement |
| Leak Test | Automated self-test with graphical troubleshooting guidance |
| Waste Gas Scavenging | Optional passive or active scavenging system |
| Compliance | Designed to meet IEC 60601-1, IEC 60601-2-13, ISO 80601-2-13, and applicable veterinary medical device regulatory requirements |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | RCT digital |
| Stirrer Type | Magnetic Stirrer |
| Max. Stirring Volume (H₂O) | 20 L |
| Speed Range | 50–1500 rpm |
| Heating Plate Temp. Range | Room Temperature + Self-Heating to 310 °C |
| Heating Power | 600 W |
| Motor Output | 9 W |
| Dimensions | 160 × 85 × 270 mm |
| Weight | 2.4 kg |
| Protection Class | IP42 |
| Interface | RS232, USB |
| Safety Circuit Adjustable Range | 50–370 °C |
| External Temperature Sensor Support | PT1000, ETS-D5, ETS-D6 |
| Heat Control Accuracy (with ETS-D6) | ±0.2 K |
| Operating Ambient | 5–40 °C, ≤80% RH |
| Voltage | 100 / 115 / 220–230 V, 50/60 Hz |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | C5000 |
| Compliance | DIN 51900, ASTM D240, ISO 1928, BS EN ISO 1928 |
| Measurement Modes | Adiabatic (~14–18 min), Isothermal (~22 min), Dynamic (~10 min) |
| Automation Features | Auto-filling, temperature equilibration & draining of water jacket |
| Accessories Included | C5000 control unit, C5003 measurement unit, C5012 halogen-resistant bomb, C5004 heat exchanger |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HS4 |
| Stirring Volume (max) | 5 L (water) |
| Speed Range | 100–1500 rpm |
| Heating Temperature Range | 50–500 °C |
| Safety Cut-off | 550 °C |
| Plate Material | Seamless Ceramic |
| Control Type | Microprocessor-based, Dual Independent Control (Speed & Temp) |
| Optional External Temperature Monitoring | Compatible with ETS-D5 Contact Thermometer (HS7/HS10 only) |
| Panel Design | Elevated Control Interface for Splash Resistance and Enhanced Readability |
| Key | Brand: IKA |
|---|---|
| Origin | Germany |
| Model | C 5000 Controlled-Mode Configuration 2/10 |
| Certification | DIN 51900, ASTM D240, ISO 1928, BSI compliant |
| Automation Features | Auto-filling, temperature regulation & draining of water jacket |
| Software | C5040 CalWin (data acquisition, calculation, audit trail, GLP-compliant reporting) |
| Accessories Included | C5000 control unit, C5003 measurement unit, C5010 standard combustion bomb, C5004 heat exchanger |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | ExoCounter |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 4000 C |
| Measurement Principle | High-Temperature Combustion (HTC) coupled with NDIR and Coulometric detection |
| Detection Elements | Total Carbon (TC), Total Sulfur (TS), Total Nitrogen (TN), Total Chlorine (Cl) |
| Sample Types | Solid organic & inorganic matrices (soils, sediments, sludges, solid waste, coal, polymers) |
| Detection Range | ppm to wt% (element-dependent) |
| Combustion Temperature | up to 1,350 °C |
| Combustion Tube Material | Composite ceramic |
| Detectors | Dual-channel NDIR for CO₂/SO₂ |
| Automation | Integrated autosampler (up to 60 positions), self-diagnostic system, automatic calibration verification |
| Compliance | Designed to meet ASTM D5373, D7359, ISO 1171, ISO 29541, EN 15407, USP <28>, EPA Method 9096A |
| Software | multiWin v5.0 with 21 CFR Part 11 compliance mode, audit trail, electronic signatures, GLP/GMP reporting templates |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HB 10 |
| Heating Power | 1300 W |
| Temperature Range | Ambient to 180 °C |
| Temperature Control | LCD microcontroller |
| Accuracy | ±1 K |
| Stability (3 L water at 90 °C) | ±1 K |
| Stability (3 L silicone oil, 50 mPa·s, at 150 °C) | ±2 K |
| Bath Capacity | 3 L |
| Minimum Fill Level | 50 mm |
| Wetted Materials | Stainless Steel 1.4404 |
| Fixed Safety Cut-off | 180 °C |
| Adjustable Safety Limit | 50–190 °C |
| Protection Class | IP21 (per DIN EN 60529) |
| Safety Compliance | DIN 12877 Class II |
| Dimensions (W×D×H) | 295 × 190 × 265 mm |
| Internal Height | 134 mm |
| External Height | 185 mm |
| Weight | 3 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Voltage/Frequency | 220–240 V / 100–120 V / 100 V, 50/60 Hz |
| Input Power | 1350 W |
| Dry-run Protection | Integrated |
| Lock Function | Yes |
| Ergonomic Side Handles | Yes |
| Compatibility | Optimized for IKA rotary evaporator glassware |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | XSR204 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability (typ.) | 0.04 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 82 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal (fully automatic FACT) |
| Weighing Pan Dimensions (W × D) | 78 mm × 73 mm |
| Linearity Error (typ.) | ±0.2 mg |
| Dimensions (H × W × D) | 292 mm × 195 mm × 482 mm |
| Connectivity | USB-B, RS232 (integrated/optional), USB-A, Bluetooth (optional), Ethernet (LAN) |
| Compliance | 21 CFR Part 11–ready (with LabX), GLP/GMP-supportive audit trail, password-protected user management |
| Software Compatibility | LabX™ |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | UCD300 |
| Operating Frequency | 20 kHz |
| Ultrasonic Power Output | 155 W / 310 W (dual-step adjustable) |
| Sample Volume Range | 5 µL – 20 mL |
| Maximum Throughput | ≥24 samples per run |
| Processing Chamber Volume | 750 mL |
| Dimensions (Controller) | 150 × 300 × 195 mm (W×D×H) |
| Dimensions (Processing Chamber) | 350 × 260 × 150 mm (W×D×H) |
| Weight | 20 kg |
| Timer Range | 0–60 sec or 0–15 min (on/off cycles) |
| Compatible Vessels | PCR tubes, 1.5 mL, 10 mL, 15 mL, and 50 mL centrifuge tubes |
| Fragmentation Range (DNA) | 2 kb – <500 bp |
| Rotation Speed | Programmable constant-speed rotation during sonication |
| Compliance | CE-marked |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 |
| Temperature Range | RT to 1600 °C |
| Mass Resolution | Sub-microgram |
| Automation | Integrated Robotic Sample Changer |
| 炉 Atmosphere Control | Hermetic Furnace Design |
| Coupling Compatibility | MS and FTIR for Evolved Gas Analysis |
| Modular Architecture | Field-upgradable Hardware Modules |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | EQ7000 |
| Water Grade | Type I (ASTM D1193-22, ISO 3696:1987, CLSI EP28-A3c) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | ≤ 5 ppb |
| Endotoxins | < 0.001 EU/mL |
| Microbial Count | < 1 CFU/100 mL |
| Particulates (>0.22 µm) | Not Detectable |
| Flow Rate | Up to 2 L/min (Q-POD® arm, three manual settings) |
| Display | 7-inch color touchscreen interface |
| Connectivity | Ethernet (DHCP/fixed IP), USB data export |
| Terminal Purifier Compatibility | Millipak®, Millipak® Gold, Biopak®, EDS-Pak®, LC-Pak®, VOC-Pak® |
| Compliance | Meets or exceeds ASTM, ISO, CLSI, and USP <1231> specifications for purified water and water for injection (WFI)-grade applications when paired with appropriate POD-Pak® modules |