ChemTron WIND XL 500H High-Purity Nitrogen Central Supply System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand ChemTron
Origin Germany
Model WIND XL 500H
Nitrogen Purity Range 95–99.999%
Nitrogen Flow Rate 100–2000 N·L/min
Max Direct Output Pressure 7.5 bar
Max Boosted Pressure 20 bar
Display 10-inch color touchscreen
Air inlet pretreatment multi-stage filtration + refrigerated dryer
Noise level 73 dB(A) ± 2
Enclosure rating (air compressor motor) IP54
Communication interfaces RS232, analog I/O, alarm relay outputs
Safety features low-pressure alarm, auto-depressurization at shutdown, compressor overtemperature protection
Compliance Designed for GLP/GMP-adjacent environments
meets ISO 8573-1 Class 2 2:2 for compressed air quality upstream of PSA unit

Overview

The ChemTron WIND XL 500H is an integrated, high-capacity nitrogen central supply system engineered for laboratories and industrial facilities requiring continuous, on-site generation of ultra-high-purity nitrogen gas. Unlike cylinder- or liquid-nitrogen-based supply methods, the WIND XL 500H employs pressure swing adsorption (PSA) technology using zeolite molecular sieves to separate nitrogen from compressed air—delivering stable output at up to 99.999% purity (≤1 ppm O₂ equivalent) without cryogenic cooling or high-pressure storage hazards. The system is fully self-contained: it incorporates an industrial-grade air compressor, refrigerated dryer, coalescing and activated carbon filtration stages, dual-tower PSA nitrogen generator, nitrogen buffer tank, pressure regulation manifold, and intelligent control architecture. Its modular design supports scalable deployment across centralized lab infrastructure—including analytical platforms (LC-MS, GC-MS), pharmaceutical cleanrooms, semiconductor fabrication lines, and food packaging production—where consistent gas quality, operational safety, and long-term TCO optimization are critical.

Key Features

  • PSA-based nitrogen generation with dual-tower configuration for uninterrupted output and automatic regeneration cycles
  • Real-time, trace-level nitrogen purity monitoring via electrochemical oxygen sensor, displaying values in % and ppm with timestamped trend logging
  • 10-inch industrial-grade color touchscreen HMI with multilingual interface (English/Chinese), intuitive navigation, and event history archive
  • Comprehensive air pretreatment: three-stage filtration (particulate, coalescing, activated carbon) followed by refrigerated drying to achieve ISO 8573-1 Class 2:2:2 compressed air quality prior to PSA feed
  • Integrated PLC-based control system compliant with IEC 61131-3 standards; supports remote diagnostics via RS232 and configurable analog I/O for integration into building management systems
  • Full safety suite: compressor motor rated IP54, low-outlet-pressure alarm, automatic depressurization before restart, thermal overload protection, and fail-safe solenoid isolation valves
  • No phthalates or plasticizers in wetted materials—validated per USP <381> and ISO 10993-5 for biocompatibility-critical applications

Sample Compatibility & Compliance

The WIND XL 500H is compatible with all nitrogen-dependent instrumentation requiring Grade 5 (99.999%) or lower purity levels—including LC-MS/MS, ELSD, CAD, nitrogen blow-down evaporators, purge-and-trap concentrators, and thermal desorption units. Its compressed air feed path adheres to ISO 8573-1:2010 Class 2 (solid particles ≤ 0.1 µm, dew point ≤ −40 °C, oil content ≤ 0.1 mg/m³), ensuring molecular sieve longevity and consistent separation performance. While not certified to FDA 21 CFR Part 11 out-of-the-box, the system’s audit-trail-capable data logger (with user-accessible CSV export) and password-protected parameter configuration support alignment with GLP and GMP documentation requirements. All wetted components are constructed from stainless steel 316L and EPDM-free fluorocarbon elastomers to prevent extractables contamination.

Software & Data Management

The embedded control firmware records all operational parameters—including inlet pressure, outlet pressure, flow rate, purity value, temperature, and alarm events—at user-defined intervals (default: 1 minute). Historical data is stored locally on a non-volatile SD card (≥16 GB) and can be exported via USB or serial dump for offline analysis. Trend curves for nitrogen purity versus time are rendered directly on the HMI and may be overlaid with flow or pressure traces for root-cause diagnostics. Optional Modbus RTU integration enables connection to SCADA or LIMS platforms for centralized gas utility monitoring. Firmware updates are performed via secure USB stick with SHA-256 signature verification.

Applications

  • Centralized nitrogen supply for multi-instrument LC-MS and GC-MS laboratories, eliminating cylinder logistics and purity variability
  • Pharmaceutical manufacturing: inerting of reactors, blanketing of API synthesis vessels, and packaging line purging under cGMP conditions
  • Semiconductor wafer processing: chamber purging, photolithography tool blanketing, and CVD/PVD process gas support
  • Food and beverage packaging: MAP (modified atmosphere packaging) nitrogen dosing systems requiring ≥99.9% purity
  • Materials science labs: glovebox inerting, thermal analysis (TGA/DSC) purge gas, and metal additive manufacturing build chambers
  • Environmental testing labs: calibration gas dilution, purge-and-trap sample preparation, and headspace analysis

FAQ

What is the typical service life of the PSA molecular sieve beds?
Under proper air pretreatment (as specified in ISO 8573-1 Class 2), the zeolite beds are rated for ≥30,000 operating hours or 8–10 years of continuous use, with annual performance verification recommended.
Can the system be integrated into an existing lab gas pipeline network?
Yes—the WIND XL 500H includes ANSI B16.5 Class 150 flanged or VCR-compatible stainless steel outlet ports (configurable per project spec) and supports pressure setpoint modulation via 4–20 mA input.
Does the system meet regulatory requirements for pharmaceutical cleanroom use?
While not intrinsically classified as “cleanroom-rated,” its particle- and hydrocarbon-free output, coupled with validated installation protocols (IQ/OQ documentation available), supports compliance with EU GMP Annex 1 and USP <1231> for process gases.
How is maintenance scheduled and tracked?
The HMI displays cumulative runtime, filter replacement timers, and predictive alerts based on pressure drop differentials across pre-filters and dryers; full maintenance logs are exportable and timestamped.
Is external cooling water required?
No—all thermal management is air-cooled; ambient operating temperature range is 10–35 °C with relative humidity ≤80% non-condensing.