- All
- Favorite
- Popular
- Most rated
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | T500 |
| Display | 3.5″ 1/4 VGA TFT color LCD |
| Pipetting Volume Range | 5–50 mL (interchangeable syringe modules) |
| Accuracy | System error ≤0.15%, random error 0.05–0.07% |
| Compliance | DIN EN ISO 8655-6 Part 3 |
| Communication | 2× USB-A, 1× USB-B, 2× RS-232-C |
| Power Supply | 90–240 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 153 × 450 × 296 mm |
| Weight | 3.5 kg (with module) |
| Wetted Materials | PTFE and borosilicate glass |
| Software Compatibility | TitriSoft 3.0 |
| Daisy-chain Capacity | Up to 16 units |
| Stirring Module Options | M1 (base), M2 (includes 20 mL smart module) |
| Volume Resolution | 0.005–0.025 mL (dependent on syringe size) |
| Viscosity Limit | <10 mm²/s |
| Operating Control | Standard mouse (included), optional mini keyboard |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | FL1703 |
| Cooling Method | Air-Cooled |
| Temperature Range | -20 to +40 °C |
| Temperature Stability | ±0.5 °C |
| Refrigeration Capacity | 1.7 kW at 20 °C |
| Pump Flow Rate | 40 L/min |
| Pump Pressure | 0.5–3.0 bar |
| Reservoir Volume | 12–17 L |
| Operating Mode | Continuous |
| Refrigerant | R404A (GWP 3922) |
| Compressor | Single-Stage Hermetic |
| Communication Interface | RS232 (optional), Profibus (optional) |
| Ambient Operating Temperature | 5–40 °C |
| Dimensions (W×L×H) | 50 × 76 × 64 cm |
| Weight | 91 kg |
| Fluid Compatibility | Water, Water/Glycol Mixtures, JULABO Thermal Bath Fluids |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | PR21S / PR21S-T |
| Sample Compatibility | Liquid process streams in pipes or reactors |
| Temperature Range | 10–60 °C (PR21S), 10–120 °C (PR21S-T) |
| Refractive Index Range | nD 1.3200–1.5200 |
| Brix Range | 0–95 % |
| Accuracy | ±0.0002 nD, ±0.2 % Brix |
| Resolution | 0.0001 nD, 0.1 % Brix |
| Wavelength | 590 nm (LED source, >100,000 h lifetime) |
| Prism Material | Sapphire |
| Temperature Sensor | PT100 (range: 10–200 °C |
| accuracy | ±0.2 °C |
| resolution | 0.1 °C) |
| Output Signals | 4–20 mA analog, RS-232, optional PROFIBUS-DP |
| Enclosure Rating | IP65 |
| Dimensions | 18.0 × 19.0 × 18.0 cm |
| Weight | 3.5 kg |
| Temperature Compensation | ICUMSA-compliant or user-definable |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | FLW7006 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | −20 to +40 °C |
| Temperature Stability | ±0.5 °C |
| Refrigeration Capacity | 7.4 kW at 20 °C |
| Pump Flow Rate | 60 L/min |
| Pump Pressure Range | 0.5–6.0 bar |
| Reservoir Volume | 39–47 L |
| Operating Mode | Continuous |
| Refrigerant | R404A (GWP = 3922) |
| Compressor | Single-Stage |
| Refrigerant Charge | 1500 g |
| CO₂-Equivalent Emissions | 5.883 t |
| Communication Interface | RS232 (optional), Profibus (optional) |
| Ambient Operating Temperature | 5–40 °C |
| Dimensions (W × L × H) | 78 × 85 × 148 cm |
| Weight | 220 kg |
| Sound Pressure Level (1 m) | ≤74 dBA |
| Fluid Compatibility | Water, Water/Glycol Mixtures, JULABO Thermal Bath Fluids |
| Inlet/Outlet Port | G1¼" external thread |
| Reservoir Fill Port | Top-access |
| Max. Return Fluid Temperature | ≤80 °C |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | M2000SP-X |
| Humidity Range | <7–95 %RH (at 23 °C) |
| Humidity Accuracy | ±0.8 %RH (at 23 °C) |
| Temperature Range | 10–55 °C |
| Temperature Accuracy | ±0.15 °C (NVLAP-calibrated) |
| Humidity Stability | 0.2 %RH (at 23 °C) |
| Temperature Stability | 0.1 °C (at 23 °C) |
| Humidity Uniformity | 0.1 %RH @ 50 %RH / 23 °C |
| Temperature Uniformity | 0.1 °C @ 50 %RH / 23 °C |
| Equilibration Time | 3–5 min (at 23 °C) |
| External Gas Flow Rate | 3 L/min (with external recirculation) |
| Internal Chamber Dimensions (standard) | 250 × 200 × 100 mm |
| Optional Extended Chamber (M2000SP-XR) | 300 × 250 × 150 mm |
| Probe Diameter Options | 10, 12, 15, 18 mm |
| Calibration Certificate | NVLAP-accredited |
| Communication Interface | RS485 (optional), software-controllable or user-programmable |
| Brand | JULABO |
|---|---|
| Model | APT-50 |
| Origin | Germany |
| Temperature Range | –25 °C to +110 °C |
| Temperature Stability | ±0.05 °C to ±0.1 °C |
| Display | 5.7″ TFT Touchscreen, 0.01 °C Resolution |
| Heating Power | 6 kW |
| Cooling Power | 7.5 kW @ 20 °C |
| Pump Flow Rate | 35–76 L/min |
| Maximum Pump Pressure | 3.2 bar |
| Primary Circulation Pump | Integrated High-Performance Dynamic Pump |
| Heat Exchanger | Single-stage, Water-Cooled Compressor System |
| Fluid Compatibility | Glycol/Water Mixtures & Other Inert Heat Transfer Media |
| Dimensions (W×D×H) | 53 cm × 66.5 cm × 126 cm |
| Compliance | CE, RoHS, ISO 9001 Design Principles |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model Series | DYNEO DD-BC4 / DD-BC6 / DD-BC12 / DD-BC26 |
| Temperature Range | +5 to 200 °C |
| Temperature Stability | ±0.01 °C |
| Set/Display Resolution | 0.01 °C |
| Display | 3.5" TFT Color Touchscreen |
| Pump Flow Rate | 8–27 L/min |
| Pump Pressure | 0.1–0.7 bar |
| Max. Bath Fluid Viscosity | ≤550 cSt |
| Bath Opening × Depth (mm) | 13×15 × 15 |
| Internal Diameter (mm) | 8 / 12 |
| Working Volume (L) | 3–4.5 |
| Ambient Operating Temperature | 5–40 °C |
| Safety Certification | DIN 12876-1 Class III (FL) for flammable fluids |
| Cooling | Integrated cooling coil (external water supply required) |
| External Sensor Input | PT100 compatible |
| Communication Interfaces | Standard USB ×2 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DM-250.2N |
| Density Range | 0–3 g/cm³ (0–3000 kg/m³) |
| Density Accuracy | ±0.0003 or ±0.0005 g/cm³ (±0.3 or ±0.5 kg/m³) |
| Temperature Range | −40 to +85 °C |
| Temperature Accuracy | ±0.1 or ±0.2 °C |
| Density Repeatability | ±0.00015 or ±0.00025 g/cm³ (±0.15 or ±0.25 kg/m³) |
| Temperature Repeatability | ±0.1 °C |
| Max. Immersion Depth | 30 m |
| Data Storage Capacity | 2000 measurements |
| Battery | NiMH 3.6 V, 1500 mAh |
| Operating Time (fully charged) | ~12 h |
| Display | OLED with backlight |
| Sensor Materials | SS 316L stainless steel, NiSpan C, or Hastelloy C-22 (optional) |
| Compliance | ATEX, IECEx, UL/CSA HazLoc |
| Units Supported | g/cm³, kg/m³, lb/gal, lb/ft³, API gravity, specific gravity (SG), ASTM D1250 petroleum tables, alcohol tables, temperature (°C/°F) |
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | CS-5B |
| Temperature Stability | ±0.03 °C |
| Bath Volume | 4.5 L |
| Circulation Type | Internal & External |
| Temperature Control | Heating & Cooling |
| Heating Method | Stainless Steel Immersion Heater |
| Control Technology | PID1 + ACC Algorithm |
| Calibration | ATC1 Single-Point Self-Calibration |
| Safety Features | Overtemperature Protection, Low-Level Float Switch with Audio-Visual Alarm & Power Cut-off, Lockable Power Plug, Dry-Run Prevention |
| Noise Level | Low-Noise Design |
| Dimensions (W×L×H) | 17 × 33 × 36 cm |
| Bath Opening/Depth | 15 × 15 / 15 cm |
| Time to Boil | 15 min |
| Pump Flow Rate | 6 L/min at 0.1 bar |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Vdose4400 |
| Instrument Type | Microfluidic Syringe Pump |
| Flow Rate | 1.25 µL/min – 375 mL/min |
| Accuracy | ≤ 0.5% (±5 ‰) |
| Weight | 9.1 kg |
| Dimensions (H×W×D) | 305 × 178 × 330 mm |
| Syringe Volume Range | 50 µL – 25 mL |
| Valve Material | Viton / PTFE |
| Wetted Materials | Glass, PTFE |
| Resolution | 1/6000 of syringe volume |
| Communication Interface | RS-232 / RS-485 |
| Power Supply | 110–240 VAC, 50/60 Hz |
| Ordering Code | V900702 |
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | CORIO CD-600F |
| Temperature Range | –35 to +150 °C |
| Temperature Stability | ±0.03 °C |
| Bath Volume | 5–7.5 L |
| Circulation Type | Internal & External |
| Cooling Method | Air-Cooled Single-Stage Compression |
| Refrigerant | R404A (GWP 3922) |
| Pump Flow Rate | 15 L/min |
| Max. Pump Pressure | 0.35 bar |
| Bath Opening | 22 × 15 × 15 cm (W × L × D) |
| Interface | USB |
| Compliance | DIN 12876-1 Class III (FL) |
| Power Supply | 230 V, 50/60 Hz |
| Weight | 36 kg |
| Dimensions (W × L × H) | 33 × 47 × 69 cm |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Digtor 22C |
| Instrument Type | Benchtop Centrifuge |
| Max Speed | 3000 rpm |
| Max RCF | 2425 × g |
| Capacity | 4 × 100 mL (for 6" or 8" tubes) |
| Dimensions (W × D × H) | 540 × 650 × 400 mm |
| Weight | 77 kg |
| Power Supply | 220–230 V, 50–60 Hz, 1260 W |
| Compliance | ASTM D91, D96, D893, D1796, D2273, D2709, D2711, D4007, D5546 |
| Safety Certifications | EN 61010-1, EN 61010-2-020, EN 61326-2-6, EN 61326-1, EN 61010-2-010 |
| Optional GRS (Gas Release System) | Air inlet pressure 2 bar, exhaust flow ≥10 L/min, cycle interval 5 min, noise <40 dB(A), power consumption 20 W |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | THI 350 |
| Temperature Range | −60 °C to +500 °C |
| Temperature Accuracy | ±1.0 °C (15–35 °C), ±2.0 °C (−33–500 °C and outside nominal range) |
| Emissivity Adjustment | 0.1–1.0 (default 0.95) |
| Temperature Resolution | 0.1 °C (−9.9 to 199.9 °C) |
| Response Time | 1 s |
| Relative Humidity Range | 1–99 % RH |
| RH Accuracy | ±3 % RH (20–80 % RH), ±5 % RH (outside that range) |
| Distance-to-Spot Ratio | 12:1 |
| Operating Ambient Temperature | 0–50 °C |
| Power | 2 × AAA alkaline batteries (typical life: 180 h, min. 140 h continuous) |
| Dimensions (L×W×H) | 46 × 143 × 184.8 mm |
| Calibration | Factory-calibrated with traceable certificate |
| Probe Types Supported | Fixed capacitive (TFH 610), flexible cable-mounted capacitive (TFH 620), and integrated infrared + capacitive (THI 350) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | EMS115 |
| Max. Flask Capacity | 72 L |
| Stirring Speed Range | 100–1850 rpm |
| Max. Heating Temperature | 450 °C |
| Power | 600 W (EMS115 variant) |
| Internal Depth | 110 mm |
| External Diameter | 305 mm |
| External Height | 298 mm |
| Weight | 3.6 kg |
| Compliance | CE, RoHS, IEC 61000-6-3 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | BR-100/300 |
| Material | SS316Ti or Hastelloy C |
| Max Operating Pressure | 200 bar |
| Max Temperature (bare) | 300 °C |
| Max Temperature (PTFE-lined) | 230 °C |
| Internal Volume | 75–225 mL |
| Sealing | Quick-release clamp with LC-KEY safety interlock |
| Stirring | Bottom-mounted magnetic stirrer (BR-100) / Top-mounted magnetic coupling stirrer (BR-300) |
| Safety Features | Burst disc, pressure relief valve (optional), nitrogen leak-tested, 1.6× pressure certification |
| Heating | Optional electric heating jacket |
| Cooling | Integrated cooling ring with solenoid valve |
| Compliance | Designed per PED 2014/68/EU, ASME BPVC Section VIII Div. 1 (as-built configuration) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | PPG |
| Reactor Volume | 10–100 L |
| Material | High-Purity Borosilicate Glass (DIN ISO 3585) |
| Operating Pressure Range | –1 to +0.5 bar (gauge) |
| Vacuum Capability | ≤20 mbar (abs) |
| Max Continuous Stirring Speed | 500 rpm |
| Short-Term Max Speed | 800 rpm |
| Jacket Inlet/Outlet Port | DN25 |
| Condenser Surface Area | 0.6 m² (DN50 P-type) |
| Temperature Range | –60 °C to +200 °C |
| Wetted Materials | Borosilicate Glass, PTFE, PFA |
| Flange Standard | DIN 2817 / ISO 2852 |
| Top Plate Configuration | 7-port DN300 lid (1×DN25 CN, 1×DN80, 3×DN40, 1×DN25, 1×DN50) |
| Bottom Valve Bore | 0–25 mm |
| Optional Accessories | Pneumatic bottom valve, integrated Pt100 temperature sensor (600–900 mm immersion length), AR1.8 Automated Reaction Control System |
| Compliance | Designed for GMP-aligned laboratory synthesis environments |
| Brand | ChemTron |
|---|---|
| Model | AEOLUS |
| Type | Membrane-Based Nitrogen Generator Module |
| Output Pressure | 7.6 bar (108 psi) |
| Flow Options | 40 / 80 / 120 L/min (at 95–96% purity) |
| Purity Options | Up to 99% N₂ |
| Compressed Air Inlet | 8.5–10 bar, ISO 8573-1 Class 1.3.1 (oil-free, dew point ≤ –20 °C) |
| Ambient Operating Temperature | 15–35 °C |
| Noise Level | < 58 dB(A) |
| Dimensions (W × D × H) | 324 × 265 × 1204 mm |
| Weight | 25–27 kg |
| Air Inlet | OD 10 mm or G1/4" |
| N₂ Outlet | OD 6 mm or G1/4" |
| Mounting | Benchtop or Wall-Mountable |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DCA400 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Surface/Interfacial Tension Accuracy | ±0.02 mN/m |
| Measurement Method | Wilhelmy Plate Method |
| Tension Range | 1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Maximum Sample Load | ≤110 g |
| Density Measurement Range (with optional accessories) | 0.5–2.25 g/cm³ |
| Density Readability/Repeatability | ±0.00005 g/cm³ |
| Power Supply | 230 V (−15% / +10%), 50 Hz, 10 VA |
| Dimensions (W × D × H) | 210 × 370 × 380 mm |
| Weight | 8 kg |
| Standard Accessories | Manual-adjustable motorized Z-stage, custom borosilicate glass plate (24 × 24 × 0.15 mm), platinum-iridium Wilhelmy plate, glass measurement beaker, temperature-controlled jacketed cup (optional), Du Noüy ring kit (optional) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Acurex 501 |
| Type | Manual Bottle Top Dispenser |
| Volume Range | 0.2–30 mL |
| Minimum Increment | 0.1–1.0 mL (model-dependent) |
| Compliance | EN ISO 8655 |
| Certification | Individual QC Certificate per Unit |
| Sterilization | Fully Autoclavable (121°C, 20 min) |
| Safety | TÜV-Certified Explosion-Safe Design |
| Wetted Materials | PTFE, FEP, ETFE, PP — Metal-Free & Static-Dissipative |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | PREMIUM |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–320,000,000 mPa·s |
| Temperature Range | −40 to +300 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Speed Range | 0.01–250 rpm (2600 selectable speeds) |
| Viscosity Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Compliance Standards | ASTM D1076, D1084, D1286, D1417, D1439, D1638, D1824, D2196, D2336, D2364, D2393, D2556, D2669, D2849, D2983, D2994, D3232, D3236, D3716 |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | FP52-SL-150C / FP55-SL-150C |
| Bath Volume | 24 L / 27 L |
| Temperature Range | −60 °C to +150 °C |
| Temperature Stability | ±0.05 °C |
| Display Resolution | 0.01 °C |
| Heating Power | 3 kW (FP52), 5.5 kW (FP55) |
| Refrigeration Power (at −60 °C) | 0.1 kW (FP52), 0.13 kW (FP55) |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Refrigerant | R404A |
| GWP | 3922 |
| DIN 12876-1 Classification | Class III (FL) |
| Communication Interfaces | RS232, RS485 (optional Profibus) |
| Programmable Ramp/Soak | 6×60 steps |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | GSA |
| Density Measurement Range | 0.9000–1.0500 g/cm³ |
| Particle Size Range | 0.001–0.1 mm |
| Sample Capacity | 12 simultaneous measurements |
| Temperature Compensation | Automatic, based on Stokes’ law |
| Repeatability | < 2% RSD |
| Compliance | ASTM D422, ISO/TS 17892-4 |
| Programmable Parameters | Soil density, gravitational acceleration, data acquisition interval, sedimentation duration |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | HP PLUS RACK |
| Nitrogen Generation Principle | CPSA (Compressed Pressure Swing Adsorption) |
| Output Flow Rate | 500 mL/min |
| Output Pressure | 5 bar (75 psig) ±0.05 bar |
| Nitrogen Purity | 99.999% |
| Dew Point | < −50 °C |
| Power Consumption | 270 W |
| Noise Level | 46 dB(A) |
| Dimensions | 19″ W × 3U H × 500 mm D |
| Input Air Requirements | 7–10 bar, oil-free and dry air per ISO 8573-1:2010 Class 1.2.1 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Camera |
| Material | SS 316 Ti |
| Max. Working Pressure | 50 bar (725 psi) |
| Max. Temperature | 300 °C (230 °C with FPM seals) |
| Volume Range | 1200–6000 mL |
| Standard Volume | 1800 mL |
| Vacuum/Pressure Rating | –1 to +25 bar (gauge) |
| Viewing Windows | Two opposing quartz windows (Ø21 mm) with integrated LED illumination |
| Explosion Protection | Ex d IIB T4 or higher (Zones 0, 1) |
| Stirring System | Magnetic coupling drive (RV 100, 100 N·cm torque, 300 °C rated, max. viscosity 4000 mPa·s) |
| Pressure Monitoring | Intrinsically safe pressure transducer (25 bar, SS 316 L) |
| Temperature Sensing | ATEX-certified Pt-100 (250 mm × 1.5 mm sheath) |
| Seals | FPM (Viton) or optional FFKM (Perlast) O-rings |
| Safety Components | Monel rupture disc (20 bar, PFA-coated, certified) |
| Jacket Type | Double-wall circulation jacket for external heating/cooling |
Show next