BrandChemTron
OriginGermany
ModelT500
Display3.5″ 1/4 VGA TFT color LCD
Pipetting Volume Range5–50 mL (interchangeable syringe modules)
AccuracySystem error ≤0.15%, random error 0.05–0.07%
ComplianceDIN EN ISO 8655-6 Part 3
Communication2× USB-A, 1× USB-B, 2× RS-232-C
Power Supply90–240 V AC, 50/60 Hz
Dimensions (W×D×H)153 × 450 × 296 mm
Weight3.5 kg (with module)
Wetted MaterialsPTFE and borosilicate glass
Software CompatibilityTitriSoft 3.0
Daisy-chain CapacityUp to 16 units
Stirring Module OptionsM1 (base), M2 (includes 20 mL smart module)
Volume Resolution0.005–0.025 mL (dependent on syringe size)
Viscosity Limit<10 mm²/s
Operating ControlStandard mouse (included), optional mini keyboard
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJulabo
OriginGermany
ModelFL1703
Cooling MethodAir-Cooled
Temperature Range-20 to +40 °C
Temperature Stability±0.5 °C
Refrigeration Capacity1.7 kW at 20 °C
Pump Flow Rate40 L/min
Pump Pressure0.5–3.0 bar
Reservoir Volume12–17 L
Operating ModeContinuous
RefrigerantR404A (GWP 3922)
CompressorSingle-Stage Hermetic
Communication InterfaceRS232 (optional), Profibus (optional)
Ambient Operating Temperature5–40 °C
Dimensions (W×L×H)50 × 76 × 64 cm
Weight91 kg
Fluid CompatibilityWater, Water/Glycol Mixtures, JULABO Thermal Bath Fluids
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelPR21S / PR21S-T
Sample CompatibilityLiquid process streams in pipes or reactors
Temperature Range10–60 °C (PR21S), 10–120 °C (PR21S-T)
Refractive Index RangenD 1.3200–1.5200
Brix Range0–95 %
Accuracy±0.0002 nD, ±0.2 % Brix
Resolution0.0001 nD, 0.1 % Brix
Wavelength590 nm (LED source, >100,000 h lifetime)
Prism MaterialSapphire
Temperature SensorPT100 (range: 10–200 °C
accuracy±0.2 °C
resolution0.1 °C)
Output Signals4–20 mA analog, RS-232, optional PROFIBUS-DP
Enclosure RatingIP65
Dimensions18.0 × 19.0 × 18.0 cm
Weight3.5 kg
Temperature CompensationICUMSA-compliant or user-definable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJulabo
OriginGermany
ModelFLW7006
Instrument TypeIntegrated Circulating Chiller
Cooling MethodWater-Cooled
Temperature Range−20 to +40 °C
Temperature Stability±0.5 °C
Refrigeration Capacity7.4 kW at 20 °C
Pump Flow Rate60 L/min
Pump Pressure Range0.5–6.0 bar
Reservoir Volume39–47 L
Operating ModeContinuous
RefrigerantR404A (GWP = 3922)
CompressorSingle-Stage
Refrigerant Charge1500 g
CO₂-Equivalent Emissions5.883 t
Communication InterfaceRS232 (optional), Profibus (optional)
Ambient Operating Temperature5–40 °C
Dimensions (W × L × H)78 × 85 × 148 cm
Weight220 kg
Sound Pressure Level (1 m)≤74 dBA
Fluid CompatibilityWater, Water/Glycol Mixtures, JULABO Thermal Bath Fluids
Inlet/Outlet PortG1¼" external thread
Reservoir Fill PortTop-access
Max. Return Fluid Temperature≤80 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelM2000SP-X
Humidity Range<7–95 %RH (at 23 °C)
Humidity Accuracy±0.8 %RH (at 23 °C)
Temperature Range10–55 °C
Temperature Accuracy±0.15 °C (NVLAP-calibrated)
Humidity Stability0.2 %RH (at 23 °C)
Temperature Stability0.1 °C (at 23 °C)
Humidity Uniformity0.1 %RH @ 50 %RH / 23 °C
Temperature Uniformity0.1 °C @ 50 %RH / 23 °C
Equilibration Time3–5 min (at 23 °C)
External Gas Flow Rate3 L/min (with external recirculation)
Internal Chamber Dimensions (standard)250 × 200 × 100 mm
Optional Extended Chamber (M2000SP-XR)300 × 250 × 150 mm
Probe Diameter Options10, 12, 15, 18 mm
Calibration CertificateNVLAP-accredited
Communication InterfaceRS485 (optional), software-controllable or user-programmable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJULABO
ModelAPT-50
OriginGermany
Temperature Range–25 °C to +110 °C
Temperature Stability±0.05 °C to ±0.1 °C
Display5.7″ TFT Touchscreen, 0.01 °C Resolution
Heating Power6 kW
Cooling Power7.5 kW @ 20 °C
Pump Flow Rate35–76 L/min
Maximum Pump Pressure3.2 bar
Primary Circulation PumpIntegrated High-Performance Dynamic Pump
Heat ExchangerSingle-stage, Water-Cooled Compressor System
Fluid CompatibilityGlycol/Water Mixtures & Other Inert Heat Transfer Media
Dimensions (W×D×H)53 cm × 66.5 cm × 126 cm
ComplianceCE, RoHS, ISO 9001 Design Principles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJulabo
OriginGermany
Model SeriesDYNEO DD-BC4 / DD-BC6 / DD-BC12 / DD-BC26
Temperature Range+5 to 200 °C
Temperature Stability±0.01 °C
Set/Display Resolution0.01 °C
Display3.5" TFT Color Touchscreen
Pump Flow Rate8–27 L/min
Pump Pressure0.1–0.7 bar
Max. Bath Fluid Viscosity≤550 cSt
Bath Opening × Depth (mm)13×15 × 15
Internal Diameter (mm)8 / 12
Working Volume (L)3–4.5
Ambient Operating Temperature5–40 °C
Safety CertificationDIN 12876-1 Class III (FL) for flammable fluids
CoolingIntegrated cooling coil (external water supply required)
External Sensor InputPT100 compatible
Communication InterfacesStandard USB ×2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelDM-250.2N
Density Range0–3 g/cm³ (0–3000 kg/m³)
Density Accuracy±0.0003 or ±0.0005 g/cm³ (±0.3 or ±0.5 kg/m³)
Temperature Range−40 to +85 °C
Temperature Accuracy±0.1 or ±0.2 °C
Density Repeatability±0.00015 or ±0.00025 g/cm³ (±0.15 or ±0.25 kg/m³)
Temperature Repeatability±0.1 °C
Max. Immersion Depth30 m
Data Storage Capacity2000 measurements
BatteryNiMH 3.6 V, 1500 mAh
Operating Time (fully charged)~12 h
DisplayOLED with backlight
Sensor MaterialsSS 316L stainless steel, NiSpan C, or Hastelloy C-22 (optional)
ComplianceATEX, IECEx, UL/CSA HazLoc
Units Supportedg/cm³, kg/m³, lb/gal, lb/ft³, API gravity, specific gravity (SG), ASTM D1250 petroleum tables, alcohol tables, temperature (°C/°F)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJULABO
OriginGermany
ModelCS-5B
Temperature Stability±0.03 °C
Bath Volume4.5 L
Circulation TypeInternal & External
Temperature ControlHeating & Cooling
Heating MethodStainless Steel Immersion Heater
Control TechnologyPID1 + ACC Algorithm
CalibrationATC1 Single-Point Self-Calibration
Safety FeaturesOvertemperature Protection, Low-Level Float Switch with Audio-Visual Alarm & Power Cut-off, Lockable Power Plug, Dry-Run Prevention
Noise LevelLow-Noise Design
Dimensions (W×L×H)17 × 33 × 36 cm
Bath Opening/Depth15 × 15 / 15 cm
Time to Boil15 min
Pump Flow Rate6 L/min at 0.1 bar
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelVdose4400
Instrument TypeMicrofluidic Syringe Pump
Flow Rate1.25 µL/min – 375 mL/min
Accuracy≤ 0.5% (±5 ‰)
Weight9.1 kg
Dimensions (H×W×D)305 × 178 × 330 mm
Syringe Volume Range50 µL – 25 mL
Valve MaterialViton / PTFE
Wetted MaterialsGlass, PTFE
Resolution1/6000 of syringe volume
Communication InterfaceRS-232 / RS-485
Power Supply110–240 VAC, 50/60 Hz
Ordering CodeV900702
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJULABO
OriginGermany
ModelCORIO CD-600F
Temperature Range–35 to +150 °C
Temperature Stability±0.03 °C
Bath Volume5–7.5 L
Circulation TypeInternal & External
Cooling MethodAir-Cooled Single-Stage Compression
RefrigerantR404A (GWP 3922)
Pump Flow Rate15 L/min
Max. Pump Pressure0.35 bar
Bath Opening22 × 15 × 15 cm (W × L × D)
InterfaceUSB
ComplianceDIN 12876-1 Class III (FL)
Power Supply230 V, 50/60 Hz
Weight36 kg
Dimensions (W × L × H)33 × 47 × 69 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelDigtor 22C
Instrument TypeBenchtop Centrifuge
Max Speed3000 rpm
Max RCF2425 × g
Capacity4 × 100 mL (for 6" or 8" tubes)
Dimensions (W × D × H)540 × 650 × 400 mm
Weight77 kg
Power Supply220–230 V, 50–60 Hz, 1260 W
ComplianceASTM D91, D96, D893, D1796, D2273, D2709, D2711, D4007, D5546
Safety CertificationsEN 61010-1, EN 61010-2-020, EN 61326-2-6, EN 61326-1, EN 61010-2-010
Optional GRS (Gas Release System)Air inlet pressure 2 bar, exhaust flow ≥10 L/min, cycle interval 5 min, noise <40 dB(A), power consumption 20 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelTHI 350
Temperature Range−60 °C to +500 °C
Temperature Accuracy±1.0 °C (15–35 °C), ±2.0 °C (−33–500 °C and outside nominal range)
Emissivity Adjustment0.1–1.0 (default 0.95)
Temperature Resolution0.1 °C (−9.9 to 199.9 °C)
Response Time1 s
Relative Humidity Range1–99 % RH
RH Accuracy±3 % RH (20–80 % RH), ±5 % RH (outside that range)
Distance-to-Spot Ratio12:1
Operating Ambient Temperature0–50 °C
Power2 × AAA alkaline batteries (typical life: 180 h, min. 140 h continuous)
Dimensions (L×W×H)46 × 143 × 184.8 mm
CalibrationFactory-calibrated with traceable certificate
Probe Types SupportedFixed capacitive (TFH 610), flexible cable-mounted capacitive (TFH 620), and integrated infrared + capacitive (THI 350)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelEMS115
Max. Flask Capacity72 L
Stirring Speed Range100–1850 rpm
Max. Heating Temperature450 °C
Power600 W (EMS115 variant)
Internal Depth110 mm
External Diameter305 mm
External Height298 mm
Weight3.6 kg
ComplianceCE, RoHS, IEC 61000-6-3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelBR-100/300
MaterialSS316Ti or Hastelloy C
Max Operating Pressure200 bar
Max Temperature (bare)300 °C
Max Temperature (PTFE-lined)230 °C
Internal Volume75–225 mL
SealingQuick-release clamp with LC-KEY safety interlock
StirringBottom-mounted magnetic stirrer (BR-100) / Top-mounted magnetic coupling stirrer (BR-300)
Safety FeaturesBurst disc, pressure relief valve (optional), nitrogen leak-tested, 1.6× pressure certification
HeatingOptional electric heating jacket
CoolingIntegrated cooling ring with solenoid valve
ComplianceDesigned per PED 2014/68/EU, ASME BPVC Section VIII Div. 1 (as-built configuration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelPPG
Reactor Volume10–100 L
MaterialHigh-Purity Borosilicate Glass (DIN ISO 3585)
Operating Pressure Range–1 to +0.5 bar (gauge)
Vacuum Capability≤20 mbar (abs)
Max Continuous Stirring Speed500 rpm
Short-Term Max Speed800 rpm
Jacket Inlet/Outlet PortDN25
Condenser Surface Area0.6 m² (DN50 P-type)
Temperature Range–60 °C to +200 °C
Wetted MaterialsBorosilicate Glass, PTFE, PFA
Flange StandardDIN 2817 / ISO 2852
Top Plate Configuration7-port DN300 lid (1×DN25 CN, 1×DN80, 3×DN40, 1×DN25, 1×DN50)
Bottom Valve Bore0–25 mm
Optional AccessoriesPneumatic bottom valve, integrated Pt100 temperature sensor (600–900 mm immersion length), AR1.8 Automated Reaction Control System
ComplianceDesigned for GMP-aligned laboratory synthesis environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
ModelAEOLUS
TypeMembrane-Based Nitrogen Generator Module
Output Pressure7.6 bar (108 psi)
Flow Options40 / 80 / 120 L/min (at 95–96% purity)
Purity OptionsUp to 99% N₂
Compressed Air Inlet8.5–10 bar, ISO 8573-1 Class 1.3.1 (oil-free, dew point ≤ –20 °C)
Ambient Operating Temperature15–35 °C
Noise Level< 58 dB(A)
Dimensions (W × D × H)324 × 265 × 1204 mm
Weight25–27 kg
Air InletOD 10 mm or G1/4"
N₂ OutletOD 6 mm or G1/4"
MountingBenchtop or Wall-Mountable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelDCA400
Instrument TypeBenchtop Laboratory Analyzer
Contact Angle Measurement Range0–180°
Surface/Interfacial Tension Accuracy±0.02 mN/m
Measurement MethodWilhelmy Plate Method
Tension Range1–1000 mN/m
Resolution0.01 mN/m
Maximum Sample Load≤110 g
Density Measurement Range (with optional accessories)0.5–2.25 g/cm³
Density Readability/Repeatability±0.00005 g/cm³
Power Supply230 V (−15% / +10%), 50 Hz, 10 VA
Dimensions (W × D × H)210 × 370 × 380 mm
Weight8 kg
Standard AccessoriesManual-adjustable motorized Z-stage, custom borosilicate glass plate (24 × 24 × 0.15 mm), platinum-iridium Wilhelmy plate, glass measurement beaker, temperature-controlled jacketed cup (optional), Du Noüy ring kit (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelAcurex 501
TypeManual Bottle Top Dispenser
Volume Range0.2–30 mL
Minimum Increment0.1–1.0 mL (model-dependent)
ComplianceEN ISO 8655
CertificationIndividual QC Certificate per Unit
SterilizationFully Autoclavable (121°C, 20 min)
SafetyTÜV-Certified Explosion-Safe Design
Wetted MaterialsPTFE, FEP, ETFE, PP — Metal-Free & Static-Dissipative
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelPREMIUM
Instrument TypeBenchtop Rotational Viscometer
Viscosity Range1–320,000,000 mPa·s
Temperature Range−40 to +300 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.2 °C
Speed Range0.01–250 rpm (2600 selectable speeds)
Viscosity Accuracy±1% of full scale
Repeatability±0.2%
Compliance StandardsASTM D1076, D1084, D1286, D1417, D1439, D1638, D1824, D2196, D2336, D2364, D2393, D2556, D2669, D2849, D2983, D2994, D3232, D3236, D3716
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJulabo
OriginGermany
ModelFP52-SL-150C / FP55-SL-150C
Bath Volume24 L / 27 L
Temperature Range−60 °C to +150 °C
Temperature Stability±0.05 °C
Display Resolution0.01 °C
Heating Power3 kW (FP52), 5.5 kW (FP55)
Refrigeration Power (at −60 °C)0.1 kW (FP52), 0.13 kW (FP55)
Pump Flow Rate22–26 L/min
Max. Pump Pressure0.7 bar
RefrigerantR404A
GWP3922
DIN 12876-1 ClassificationClass III (FL)
Communication InterfacesRS232, RS485 (optional Profibus)
Programmable Ramp/Soak6×60 steps
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelGSA
Density Measurement Range0.9000–1.0500 g/cm³
Particle Size Range0.001–0.1 mm
Sample Capacity12 simultaneous measurements
Temperature CompensationAutomatic, based on Stokes’ law
Repeatability< 2% RSD
ComplianceASTM D422, ISO/TS 17892-4
Programmable ParametersSoil density, gravitational acceleration, data acquisition interval, sedimentation duration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelHP PLUS RACK
Nitrogen Generation PrincipleCPSA (Compressed Pressure Swing Adsorption)
Output Flow Rate500 mL/min
Output Pressure5 bar (75 psig) ±0.05 bar
Nitrogen Purity99.999%
Dew Point< −50 °C
Power Consumption270 W
Noise Level46 dB(A)
Dimensions19″ W × 3U H × 500 mm D
Input Air Requirements7–10 bar, oil-free and dry air per ISO 8573-1:2010 Class 1.2.1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelCamera
MaterialSS 316 Ti
Max. Working Pressure50 bar (725 psi)
Max. Temperature300 °C (230 °C with FPM seals)
Volume Range1200–6000 mL
Standard Volume1800 mL
Vacuum/Pressure Rating–1 to +25 bar (gauge)
Viewing WindowsTwo opposing quartz windows (Ø21 mm) with integrated LED illumination
Explosion ProtectionEx d IIB T4 or higher (Zones 0, 1)
Stirring SystemMagnetic coupling drive (RV 100, 100 N·cm torque, 300 °C rated, max. viscosity 4000 mPa·s)
Pressure MonitoringIntrinsically safe pressure transducer (25 bar, SS 316 L)
Temperature SensingATEX-certified Pt-100 (250 mm × 1.5 mm sheath)
SealsFPM (Viton) or optional FFKM (Perlast) O-rings
Safety ComponentsMonel rupture disc (20 bar, PFA-coated, certified)
Jacket TypeDouble-wall circulation jacket for external heating/cooling