Waters 2996 Photodiode Array Detector
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | 2996 PDA Detector (Refurbished) |
| Product Category | Chromatography |
| Operational Age | 3–4 Years |
| Warranty | 6 Months |
| Condition | Fully Tested & Certified Refurbished |
| Regulatory Compliance | Meets Original Waters Factory Specifications for Performance and Safety |
Overview
The Waters 2996 Photodiode Array (PDA) Detector is a high-performance, benchtop UV-Vis spectral detection system designed for integration with Waters Alliance and other compatible HPLC platforms. Engineered for precision chromatographic analysis, it employs a 1024-element silicon photodiode array to acquire full-spectrum data (190–800 nm) across the entire chromatographic peak—enabling real-time spectral deconvolution, peak purity assessment, and compound identification without post-run re-injection. Its optical architecture features a fixed-pathlength flow cell (typically 10 mm × 10 µL), dual-beam referencing, and thermoelectrically stabilized optics to ensure baseline stability and wavelength accuracy (±1 nm). As a legacy but widely validated instrument in regulated laboratories, the 2996 PDA complies with core instrumental performance requirements outlined in USP , ICH Q2(R2), and ASTM E2675 for UV-Vis detector qualification.
Key Features
- Full-spectrum acquisition at up to 20 Hz sampling rate, supporting dynamic spectral monitoring during gradient elution
- Wavelength range: 190–800 nm with 1.2 nm resolution (nominal); calibrated using holmium oxide and didymium filters per NIST-traceable protocols
- Photometric linearity verified over 0–2.5 AU range (typical), with noise ≤ ±2.5 × 10⁻⁶ AU (254 nm, 1 sec bandwidth)
- Integrated flow cell temperature control (ambient ±2 °C) to minimize refractive index drift and retention time variability
- Rugged mechanical design with sealed optical path and redundant lamp monitoring (deuterium + tungsten halogen sources)
- Factory-refurbished units undergo full electrical calibration, optical alignment verification, and leak-tightness validation of the flow path
Sample Compatibility & Compliance
The 2996 PDA is compatible with standard HPLC mobile phases—including aqueous buffers, acetonitrile, methanol, and THF—provided they are UV-transparent within the selected detection window. It supports stainless steel, PEEK, and fused silica capillary connections (1/16″ OD tubing, 0.005″ ID typical). All refurbished units are certified to meet original Waters specifications for wavelength accuracy, photometric accuracy, and signal-to-noise ratio as defined in Waters Service Manual 71500-00100. Documentation includes Certificate of Refurbishment, IQ/OQ test reports aligned with ISO/IEC 17025 principles, and traceability to manufacturer-recommended maintenance intervals. Units are suitable for GLP-compliant environments when deployed with appropriate audit trail-enabled software (e.g., Empower 3 FR or OpenLab CDS).
Software & Data Management
The detector operates natively under Waters Empower™ Chromatography Data System (CDS) versions 2.x and 3.x (Fixed Response and FR modes), supporting full spectral library generation, peak tracking, and spectral overlay. Raw data files (.arw) retain complete wavelength-time-intensity matrices, enabling retrospective analysis and multivariate curve resolution (MCR). For laboratories requiring 21 CFR Part 11 compliance, Empower 3 FR provides electronic signatures, role-based access control, and immutable audit trails for all acquisition and processing events. SpectraLab Scientific supplies each unit with a validated installation package including firmware version logs, calibration history, and configuration backup files—all archived for customer access.
Applications
- Pharmaceutical impurity profiling and forced degradation studies requiring peak purity confirmation (ICH Q5A)
- Method development and transfer support for stability-indicating assays per ICH Q1–Q5 guidelines
- Natural product fingerprinting and botanical extract characterization via spectral library matching
- Quality control of small-molecule APIs where multi-wavelength quantitation improves selectivity in complex matrices
- Educational and research labs requiring cost-effective, spectrally resolved HPLC detection with proven method robustness
FAQ
Is this unit eligible for extended warranty or service contracts?
Yes—SpectraLab Scientific offers optional 12- or 24-month extended service agreements covering parts, labor, and on-site calibration by Waters-certified field engineers.
Does the refurbishment include replacement of critical wear components?
Yes—each unit receives new deuterium and tungsten lamps, flow cell gaskets, and optical window seals; all replaced components are logged in the Certificate of Refurbishment.
Can the 2996 PDA be integrated with non-Waters HPLC systems?
It supports analog voltage output (0–1 V) and RS-232 communication for basic integration; however, full spectral control and data acquisition require native Empower or OpenLab CDS drivers.
What documentation accompanies the shipment?
Customers receive a comprehensive dossier: Certificate of Refurbishment, IQ/OQ test report, firmware version record, calibration certificate (wavelength & photometric), and shipping manifest with serial-number traceability.
Are spare parts and consumables available through SpectraLab Scientific?
Yes—we maintain inventory of flow cells (catalog #WAT026270), lamp kits (WAT026271, WAT026272), and diode array alignment tools for rapid field support.