PerkinElmer AutoSystem GC System with Nitrogen-Phosphorus Detector (NPD) and Flame Ionization Detector (FID)
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem GC with NPD & FID |
| Detector Types | Nitrogen-Phosphorus Detector (NPD), Flame Ionization Detector (FID) |
| Instrument Category | Gas Chromatograph (GC) |
| Age | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Compliance | Meets original PerkinElmer factory specifications for GC operation and detector performance |
Overview
The PerkinElmer AutoSystem GC is a robust, benchtop gas chromatography system originally engineered for routine and regulated analytical laboratories requiring high sensitivity, reproducibility, and method transfer capability. This refurbished unit integrates two complementary detection technologies: the Nitrogen-Phosphorus Detector (NPD), optimized for selective, low-level detection of nitrogen- and phosphorus-containing compounds (e.g., pesticides, alkaloids, organophosphates), and the Flame Ionization Detector (FID), a universal, quantitative detector widely accepted for hydrocarbon analysis across environmental, petrochemical, and quality control applications. The system operates on proven dual-beam pneumatic control architecture, supporting split/splitless injection, temperature-programmed oven ramping, and precise carrier gas flow regulation via electronic pressure control (EPC). Its modular design allows for straightforward maintenance and long-term operational stability—key attributes for laboratories managing extended instrument lifecycles under GLP or ISO/IEC 17025 frameworks.
Key Features
- Refurbished and functionally validated by SpectraLab Scientific’s certified GC service engineers, including leak testing, baseline stability assessment, detector sensitivity verification (e.g., NPD response to triethyl phosphate, FID response to n-decane), and column oven thermal calibration.
- Dual-detector configuration enables concurrent or sequential analysis without hardware reconfiguration—reducing turnaround time for multi-analyte screening workflows.
- Compatible with standard 0.53 mm, 0.32 mm, and 0.25 mm ID fused-silica capillary columns; supports both manual and autosampler-based injection (e.g., PerkinElmer AS-100 or equivalent).
- Integrated data acquisition and control via PerkinElmer TurboMass™ or third-party GC software platforms compliant with ASTM D3699 (hydrocarbon analysis) and EPA Method 8081B (organochlorine pesticides).
- Factory-aligned thermal management ensures ±0.1 °C oven temperature accuracy over 35–300 °C range; cool-down from 300 °C to 50 °C in <6 min (typical).
Sample Compatibility & Compliance
This AutoSystem GC system accommodates volatile and semi-volatile organic compounds across diverse matrices—including water extracts (EPA 508, 525), soil leachates, food homogenates, and pharmaceutical excipients—when paired with appropriate sample preparation (e.g., liquid–liquid extraction, solid-phase microextraction). The NPD delivers sub-picogram detection limits for nitrogenous analytes (e.g., 0.5 pg N/sec for methyl parathion), while the FID achieves linear dynamic range >10⁷ for C₁–C₁₂ hydrocarbons. All detector modules retain original PerkinElmer calibration protocols and are traceable to NIST-traceable standards. The system meets functional requirements for USP , ASTM E260, and ISO 17025 clause 5.9 (method validation), and supports audit-ready electronic records when operated under 21 CFR Part 11-compliant software environments.
Software & Data Management
The system ships with full firmware compatibility for PerkinElmer’s TurboMass v6.x or later, enabling peak integration, calibration curve generation, retention time locking (RTL), and automated reporting. Raw data files (.raw) are fully exportable in AIA/ANDI format for cross-platform interoperability with OpenLAB CDS, Chromeleon, or Empower. Audit trail functionality—including user login logs, method change history, and run sequence metadata—is preserved post-refurbishment. SpectraLab provides documented evidence of software reinstatement, detector parameter reset, and firmware version verification prior to shipment.
Applications
- Environmental monitoring: Pesticide residue screening in drinking water per EPA Methods 508/8081B; chlorinated hydrocarbon profiling in sediment samples.
- Food safety: Detection of mycotoxin metabolites (e.g., aflatoxin B1 derivatives) and veterinary drug residues (e.g., sulfonamides) using NPD-selective quantitation.
- Pharmaceutical QC: Residual solvent analysis (ICH Q3C) and impurity profiling of active pharmaceutical ingredients (APIs) per USP .
- Fuel and lubricant analysis: Hydrocarbon-type distribution (saturates, olefins, aromatics) in gasoline and jet fuel per ASTM D5186 and D6730.
FAQ
Is this instrument supplied with a valid calibration certificate?
Yes—each unit undergoes full functional recalibration prior to shipment, and a traceable Certificate of Performance Verification (including NPD/FID sensitivity, linearity, and retention time repeatability data) is provided.
Can I integrate this GC with my existing LIMS or CDS platform?
Yes—the system supports standard RS-232, Ethernet, and USB interfaces; drivers and protocol documentation for OpenLAB CDS, Chromeleon, and Thermo Xcalibur are available upon request.
What consumables and spare parts are included?
The package includes one set of inlet septa, three gold-plated ferrules, one O-ring kit for the NPD jet assembly, and a certified reference standard mix for initial system suitability testing.
Does the 6-month warranty cover detector components?
Yes—the warranty covers all detector electronics, thermocouples, ceramic igniters (FID), rubidium bead (NPD), and oven heater elements against manufacturing defects and refurbishment-related failures.
Is remote diagnostic support available after purchase?
Yes—SpectraLab offers optional remote connectivity setup and quarterly health-check teleconsultations for registered instruments.