PerkinElmer
Filter
Showing 1–30 of 175 results
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | LPC500 + Avio500 |
| Application | Elemental Analysis & Particle Counting in Lubricants |
| Sample Volume | <1 mL per dual analysis |
| Cycle Time | ≤45 seconds per sample |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 2400 Series II |
| Analysis Modes | CHN, CHNS, O |
| Typical Analysis Time | 4–8 min per mode |
| Sample Weight Range | 1–2 mg (CHN/CHNS), matrix-dependent for O |
| Detection Principles | Combustion–Reduction–Gas Chromatography–Thermal Conductivity Detection (TCD) |
| Gas Requirements | Helium or Argon carrier gas |
| Compliance | Designed for GLP/GMP environments |
| Software | Elemental Analyzer Data Manager (EADM) v3.x |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 2400 |
| Operating Modes | CHN, CHNS, O |
| Analysis Time | 4–8 min |
| Accuracy (CHN/CHNS/O) | ≤0.3% |
| Precision (CHN/CHNS/O) | ≤0.2% |
| Detection Range (C/H/N/S/O) | 0.001–6.0 mg |
| Combustion/Reduction/Pyrolysis Furnace Temp | 100–1800 °C |
| Carrier Gases | He, Ar |
| Brand | PerkinElmer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Mode Flame/GF-AAS |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + AC Zeeman |
| Spectral Resolution | 0.1 nm |
| Sensitivity | Flame (Cu): ≤0.02 µg/mL |
| GF-AAS (Cd) | ≤5.0×10⁻¹³ g |
| Precision (RSD) | Flame (Cu): ≤0.45% |
| GF-AAS (Cd) | ≤3.0% |
| Detection Limit | Flame (Cu): ≤0.003 µg/mL |
| GF-AAS (Cd) | ≤1.0×10⁻¹² g |
| Baseline Stability | ≤0.002 A/30 min (static) |
| Lamp Turret | 8-position Auto-rotating |
| Graphite Furnace | Transversely Heated |
| Magnetic Field | AC Zeeman, 0.6–1.1 T adjustable in 0.1 T increments |
| Optional Features | Integrated Graphite Furnace Viewing System |
| Brand | PerkinElmer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | XES-40S3-TT-200 |
| Light Source Type | Xenon Arc Lamp |
| Illumination Mode | External Irradiation |
| Radiation Area | 40 × 40 mm² |
| Spectral Match | AM1.5G (Class A) |
| Temporal Instability | <1% (Class A) |
| Spatial Uniformity | ±2% (Class A) |
| Initial Irradiance | 1.0 sun (100 mW/cm²) |
| Adjustable Irradiance Range | 70–130% of 1.0 sun |
| Lamp Lifetime | 2000 h (1000 h warranty) |
| Collimation Angle | ±4° |
| Shutter Timing Range | 0.1 s to 9990 h |
| Output Orientation Options | Vertical downward, vertical upward, horizontal left/right, 45° mirror-reflected |
| Expandable Functions | Neutral density attenuation, spectral bandpass filtering |
| Input Voltage | AC 100–220 V ±10%, 50/60 Hz |
| Operating Environment | 5–35 °C, 20–85% RH |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 200 |
| Instrument Type | Atomic Absorption Spectrometer (Flame & Graphite Furnace Capable) |
| Optical System | True Dual-Beam Stepped Optics with Solid-State Detector |
| Gas Control | Fully Automated Flame Gas Management with Integrated Safety Interlocks |
| Warranty | 6 Months Limited Hardware Warranty |
| Operational Age | 3–4 Years |
| Compliance | Designed to meet ASTM E1941, ISO 8288, and USP <731> requirements for elemental analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 200 / AAnalyst 400 |
| Optical System | Echelle grating double-beam monochromator |
| Wavelength Range | 190–900 nm |
| Spectral Bandpass | 0.15 nm (AAnalyst 200), 0.12 nm (AAnalyst 400) |
| Focal Length | 300 mm |
| Grating Size | 36 × 185 mm, 79 lines/mm |
| Detector | Segmented solid-state detector |
| Lamp Support | Dual power supply for hollow-cathode lamps (HCLs) and electrodeless discharge lamps (EDLs) |
| Safety | Full flame interlock system with gas flow, burner head, drain level, and flame monitoring |
| Operating Temperature | 15–35 °C |
| Relative Humidity | 20–80 % RH (non-condensing) |
| Dimensions | 70 × 65 × 65 cm |
| Weight | 49 kg |
| Power | 100–230 V AC, ±10 %, 50/60 Hz, ≤300 VA |
| Refurbishment Age | 3–4 years |
| Warranty | 6 months |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AAnalyst 400 |
| Operational Age | 4–5 Years |
| Warranty | 6 Months |
| Configuration | Fully Refurbished with PC and AA Software |
| Compliance Status | Fully Tested and Certified per ASTM E1908-22 and ISO/IEC 17025 Calibration Protocols |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 600 |
| Instrument Type | Atomic Absorption Spectrometer |
| Age | 4 years |
| Warranty | 6 months |
| Compliance | ASTM E2173, ISO/IEC 17025-compatible operation |
| Software | WinLab32 v3.52 with instrument control and data reporting modules |
| Lamp Compatibility | Hollow Cathode Lamps (HCLs) and Electrodeless Discharge Lamps (EDLs) |
| Atomization | Flame and Graphite Furnace (with optional GF-3000 upgrade path) |
| Detection Limit (Flame) | Sub-ppb for Cu |
| (GF) | Low-pg range for Cd/Pb |
| Optical System | Double-beam, monochromator with 0.1/0.2/0.5/1.0 nm slit widths |
| Wavelength Range | 190–900 nm |
| Data Output | CSV, XML, PDF reports compliant with GLP audit trails |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AAnalyst 600 |
| Service Fee | USD 700–1,400 (excl. parts) |
| Field Experience | 10+ years |
| Instrument Type | Analytical Instrument |
| Response Time | Within 12 hours |
| Service Scope | AAS hardware diagnostics, optical alignment, burner head cleaning & replacement, nebulizer & spray chamber servicing, graphite furnace maintenance (if applicable), software calibration verification, lamp alignment & intensity optimization |
| Geographic Coverage | Beijing-based on-site support with nationwide remote diagnostics capability |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 600 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal |
| Resolution | 0.3 nm |
| Sensitivity | Cu 5 ppm, Absorbance > 0.3 A |
| Repeatability (RSD) | < 0.3% |
| Detection Limit | Cu ≤ 0.006 mg/L |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 800 |
| Wavelength Range | 189–900 nm |
| Detector | Array-type CCD with integrated low-noise CMOS charge amplifier |
| Slit Width & Height | Motorized automatic selection |
| Lamp Compatibility | Hollow Cathode Lamps (HCL) and Electrodeless Discharge Lamps (EDL) |
| Flame System | Titanium burner head, inert pre-mix chamber, adjustable nebulizer |
| Graphite Furnace | Integrated power supply, IR temperature monitoring with voltage and resistance compensation, STPF platform-coated graphite tubes |
| Sample Introduction | Direct suspension injection for flame and furnace modes |
| Hydride Generation Compatibility | Fully compatible with domestic HG systems (e.g., As, Sb, Se, Hg) |
| FIAS-GF Coupling | Supported for online preconcentration |
| Software | WinLab32 v3.50+ (peak area/height quantitation, lamp auto-identification, method automation) |
| Compliance | Designed to support GLP/GMP workflows |
| Warranty | 6 months limited hardware warranty |
| Operational Age | 4 years |
| Certification | Factory-tested and performance-verified by SpectraLab Scientific |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 800 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Automatic Deuterium/Hollow Cathode Lamp (D₂/HCL) |
| Spectral Resolution | 0.3 nm |
| Sensitivity | ≥ 0.3 A for 5 ppm Cu solution |
| Precision (RSD) | < 0.3% |
| Detection Limit (Cu) | ≤ 0.006 mg/L |
| Compliance | ASTM E1921, ISO 7185, USP <731>, FDA 21 CFR Part 11–ready software environment |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Altus HPLC A10 |
| Instrument Age | 4–5 years in service (7-year total design life) |
| Warranty | 6 months |
| Configuration | PDA Detector, Solvent & Sample Module, Column Module, LabSolutions-compatible PC, tubing and interconnects included |
| Compliance | Fully tested per ASTM E2653-22 (Standard Guide for Verification of HPLC Systems) |
| Software Environment | Compatible with Waters Empower 3 (via standard ASCII/CSV export) and PerkinElmer’s legacy Turbochrom software |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | ARVO X3 |
| Condition | Factory-Refurbished |
| Configuration | Complete System with Onboard Software, Filter Wheels, and Standard Optical Modules |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S/SL |
| Product Category | Chromatography |
| Usage Duration | 4–5 Years |
| Warranty Period | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AutoSystem GC |
| Instrument Type | Gas Chromatograph |
| Year of Manufacture | ~2016–2018 (7-year-old unit) |
| Warranty | 6 months |
| Configuration | Capillary/Split-Splitless Inlet, Programmable Temperature Vaporizing (PTV) Inlet, Cold-On-Column Inlet, Packed Column Inlet, Autosampler, FID/PID/NPD/ECD/TCD/FPD Detectors |
| Compliance | Fully refurbished and functionally validated per ISO/IEC 17025-aligned internal protocol |
| Software | Turbochrom v6.3.2 (or later compatible version) |
| Delivery Status | Ready-to-ship, bench-tested and calibrated |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem ECD |
| Instrument Type | Gas Chromatograph |
| Detector Configuration | Dual Electron Capture Detector (ECD) |
| Age | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Regulatory Compliance | Designed to meet ASTM D5845, EPA Method 8081B/8270, and ISO 10380 requirements for trace halogenated compound analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem GC with NPD & FID |
| Detector Types | Nitrogen-Phosphorus Detector (NPD), Flame Ionization Detector (FID) |
| Instrument Category | Gas Chromatograph (GC) |
| Age | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Compliance | Meets original PerkinElmer factory specifications for GC operation and detector performance |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem TCD |
| Instrument Category | Gas Chromatograph |
| Detector Type | Thermal Conductivity Detector (TCD) |
| Automation | Integrated Autosampler |
| Condition | Refurbished & Fully Tested |
| Operational Age | >7 years |
| Warranty | 6 months |
| Regulatory Compliance | Designed to meet ASTM D1945, ISO 6974, and USP <621> gas chromatography requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem GC |
| Detector Configuration | Dual FID |
| Instrument Category | Gas Chromatograph |
| Age | 5–7 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Regulatory Compliance | Meets ASTM D3606, ISO 15528, and USP <621> for hydrocarbon and volatile organic compound analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Model 40 Headspace |
| Product Category | Chromatography |
| Operational Age | 5–7 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PID-ELCD |
| Product Category | Chromatography |
| Operational Age | 5–7 Years |
| Warranty Period | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem XL |
| Instrument Category | Gas Chromatograph |
| Age | 5–7 years |
| Warranty | 6 months |
| Configuration | Refurbished, Fully Tested |
| Regulatory Compliance | Designed to meet ASTM D3606, ISO 6416, and USP <621> chromatographic system suitability requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Autosystem XL |
| Instrument Type | Gas Chromatograph |
| Year of Manufacture | ≥7 years old |
| Warranty | 6 months |
| Regulatory Compliance | Designed to meet ASTM D3606, ISO 10301, and USP <621> chromatographic system suitability requirements |
| Software Compatibility | Native support for TurboChrome v5.x and optional migration to Chromeleon CDS (via hardware interface adapter) |
| Detector Options Supported | FID, TCD, ECD, NPD, FPD, PID |
| Injector Types Supported | Split/splitless capillary inlet, programmable temperature vaporizing (PTV) inlet, cold-on-column (COC) inlet, packed column inlet |
| Automation | Compatible with PerkinElmer AS-100/AS-200 series autosamplers |
| Operating Environment | 15–35 °C, 20–80% RH non-condensing |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Avio 200 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Gas Consumption | <8 L/min Ar (typical operational mode) |
| Startup Time | <5 minutes from cold start to analysis-ready |
| Dual-View Capability | Axial and Radial Simultaneous Observation without Sensitivity Loss |
| Linear Dynamic Range | Up to 9 orders of magnitude |
| Detector | Back-Illuminated CCD with On-Chip Background Correction |
| Plasma Technology | Flat Plate™ RF Generator and PlasmaShear™ Air-Based Tail Flame Elimination |
| Torch Orientation | Vertical, Tool-Free Adjustable Base with Interchangeable Injector Tubes |
| Software Platform | Syngistix for ICP-OES (21 CFR Part 11 Compliant) |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Avio 500 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Argon Consumption | <10 L/min (typical operational mode) |
| Plasma Orientation | Dual-View (Axial & Radial) |
| Plasma Technology | Flat Plasma™ |
| Background Correction | Real-Time Synchronous Background Correction |
| Detection Capability | Multi-element, simultaneous quantitative analysis of metals and some non-metals in liquid samples |
| Software Platform | Syngistix™ for ICP-OES |
| Brand | PerkinElmer |
|---|---|
| Model | Avio 550 |
| Origin | Imported |
| Configuration | Refurbished Unit |
| Dimensions (W×D×H) | 76 × 84 × 87 cm |
| Plasma Observation | Dual-view (Axial and Radial) |
| Detection Principle | Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) |
| Nebulization System | 4-channel, 12-roller peristaltic pump |
| Plasma Torch Design | Vertical, tool-free, maintenance-free torch with integrated tail-flame cutoff |
| Argon Consumption | Ultra-low |
| Diagnostic Capability | Real-time plasma imaging via integrated color plasma camera |
| Data Acquisition | Universal Data Acquisition (UDA) — full-wavelength, simultaneous, time-resolved detection |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Avio 550/560 |
| Pricing | Upon Request |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Plasma Configuration | Dual-View (Axial and Radial) |
| Detection Technology | Solid-State CCD Detector Array |
| Gas Consumption | Ultra-Low Argon Flow (<10 L/min typical plasma gas) |
| Torch Design | Vertical, Tool-Free, Maintenance-Free Plasma Torch with Integrated Tail-Flame Suppression |
| Optical System | Flat-Field Echelle Spectrometer with UV-Visible Wavelength Coverage (165–900 nm) |
| Pump System | 4-Channel, 12-Roller Peristaltic Pump |
| Dimensions (W×D×H) | 76 × 84 × 87 cm |
| Camera Integration | Integrated Color Plasma Torch Imaging System for Real-Time Torch & Injector Monitoring |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Avio® 550 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Plasma Orientation | Vertical Torch Configuration |
| Software Platform | Syngistix™ for ICP |
| Sample Introduction System | Scott/Cross-Flow Nebulizer with Cyclonic Spray Chamber |
| Optional Capability | HF-Compatible Sample Handling |