Empowering Scientific Discovery

PerkinElmer AutoSystem XL Gas Chromatograph

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand PerkinElmer
Origin Canada
Model AutoSystem XL
Instrument Category Gas Chromatograph
Age 5–7 years
Warranty 6 months
Configuration Refurbished, Fully Tested
Regulatory Compliance Designed to meet ASTM D3606, ISO 6416, and USP <621> chromatographic system suitability requirements

Overview

The PerkinElmer AutoSystem XL Gas Chromatograph is a robust, benchtop-capable GC platform originally engineered for high-throughput routine analysis in environmental, petrochemical, and quality control laboratories. Built on a modular architecture with temperature-programmable oven, precision electronic pressure control (EPC) for carrier gas, and a dual-channel detector interface, the AutoSystem XL implements classical capillary and packed column separation principles grounded in differential partitioning kinetics and retention time-based analyte identification. This refurbished unit has undergone full functional validation—including baseline stability assessment, retention time reproducibility testing (<0.02 min RSD), and detector linearity verification across calibration ranges—by SpectraLab Scientific’s certified instrumentation engineers. All critical subsystems—including the injection port (split/splitless mode), column oven (ambient to 350 °C, ±0.1 °C stability), and detector electronics—have been recalibrated and verified per manufacturer-recommended protocols.

Key Features

  • Fully refurbished and performance-validated AutoSystem XL chassis with original PerkinElmer firmware (v3.2.x compatible)
  • Electronic Pressure Control (EPC) for helium, hydrogen, or nitrogen carrier gases—enabling precise flow programming and method transfer reproducibility
  • Dual independent detector bays supporting simultaneous FID and TCD configurations; FID detection limit ≤1.8 pg C/sec (n-decane), TCD sensitivity ≥8,000 mV·mL/mg (benzene)
  • Temperature-controlled oven with ramp rates up to 40 °C/min and isothermal hold capability for extended method robustness
  • Auto-sampler compatibility (e.g., AS-50 or equivalent third-party interfaces) validated during refurbishment
  • Integrated data acquisition via PerkinElmer TurboMass™ or Chromera™ software environment (license not included; compatible with legacy TurboChrom v6.2+)

Sample Compatibility & Compliance

The AutoSystem XL supports volatile and semi-volatile organic compound (VOC/SVOC) analysis across matrices including water, soil extracts, fuels, polymers, and pharmaceutical excipients. It accommodates standard 0.25–0.53 mm ID fused-silica capillary columns (up to 60 m length) and packed stainless-steel or glass columns. Method development adheres to ICH Q2(R2) guidelines for analytical procedure validation, and system suitability testing fulfills USP , EP 2.2.46, and ASTM D3606 (benzene/toluene/xylene in gasoline) requirements. The instrument’s hardware architecture meets electromagnetic compatibility (EMC) standards per CISPR 11 Group 1 Class A and operates within laboratory environments compliant with ISO/IEC 17025:2017 clause 6.4 (equipment management).

Software & Data Management

While the hardware is fully operational, software licensing is not included with this refurbished unit. The system is compatible with PerkinElmer’s TurboChrom v6.2 or newer, which supports 21 CFR Part 11-compliant audit trails, electronic signatures, and secure user role assignment when deployed on validated Windows OS platforms (Windows 7 SP1 or later, 64-bit). Raw data files (.ch, .raw) are stored in vendor-neutral formats readable by open-source tools such as OpenChrom. SpectraLab Scientific provides documented evidence of firmware integrity, EPC calibration certificates, and post-refurbishment system suitability reports—essential for GLP/GMP-regulated labs undergoing internal or external audits.

Applications

  • Environmental testing: EPA Method 8240C (SVOCs in solid waste), 8021B (aromatics in water)
  • Petrochemical QA/QC: ASTM D3606 (BTX in reformulated gasoline), D5186 (determining aromatic content)
  • Pharmaceutical residual solvent analysis per ICH Q3C guidelines using headspace-GC/FID
  • Food safety screening: Pesticide residue profiling (e.g., organophosphates) via GC-ECD or GC-MS coupling
  • Polymers and adhesives: Monomer purity assessment and extractables profiling

FAQ

Is this instrument supplied with original PerkinElmer documentation?
Yes—each unit includes scanned copies of the original operator manual, maintenance guide, and factory calibration records.
Can the AutoSystem XL be integrated into an existing LIMS environment?
Yes, via ODBC-compliant data export or third-party middleware (e.g., Thermo Fisher SampleManager or LabVantage); configuration support available upon request.
What consumables are recommended for immediate operation?
We recommend PerkinElmer-certified inlet septa (P/N N9302410), gold-plated ferrules (N9306010), and certified reference standards traceable to NIST SRMs.
Does the 6-month warranty cover labor and parts globally?
Warranty covers parts and labor for defects in materials or workmanship within the first six months from shipment date; service is performed remotely or via authorized field engineer dispatch where feasible.
Is method transfer support provided?
SpectraLab Scientific offers optional paid method migration assistance—including parameter translation, system suitability revalidation, and report template alignment—for regulated lab deployments.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0