Empowering Scientific Discovery

XiYou XYH-300 Hydrogen Generator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand XiYou
Origin Shanghai, China
Model XYH-300
Hydrogen Output Flow 0–300 mL/min
Output Pressure 0–0.4 MPa (factory-set at 0.3 MPa)
Hydrogen Purity 99.999%
Power Consumption 150 W
Generation Principle Pure Water Electrolysis
Construction Electropolished Stainless Steel Tubing, Dual-Stage Purification, Anti-Backflow Design, Cylindrical Electrolytic Cell with Imported Noble-Metal Catalysts
Warranty 1-year system warranty, 3-year electrolyzer warranty

Overview

The XiYou XYH-300 Hydrogen Generator is a laboratory-grade, on-demand hydrogen source engineered for continuous, high-purity gas supply in analytical applications—particularly as a carrier or fuel gas for gas chromatography (GC), GC-MS, and other instrumentation requiring ultra-high-purity hydrogen. It employs zero-additive pure water electrolysis (no KOH or NaOH required), eliminating alkali handling hazards and minimizing maintenance overhead. The core electrolytic cell adopts a cylindrical, thermally stabilized architecture with imported noble-metal catalysts, ensuring consistent catalytic activity, uniform current distribution, and extended operational lifetime under sustained load. Hydrogen is generated at ambient temperature and pressure, then pressurized via an integrated diaphragm compressor to a maximum of 0.4 MPa (60 psi), with factory default setpoint at 0.3 MPa for optimal compatibility with standard GC pneumatic controllers. All wetted gas-path components—including tubing, fittings, and purification modules—are constructed from electropolished 316L stainless steel and subjected to ultrasonic cleaning prior to assembly, guaranteeing low metallic leaching and minimal background contamination.

Key Features

  • Pure water electrolysis technology—no caustic electrolytes; only deionized or distilled water required for operation
  • Stable hydrogen output flow (0–300 mL/min) with real-time pressure feedback and automatic flow tracking to match instrument demand
  • Dual-stage gas purification: integrated palladium-doped molecular sieve + copper-based oxygen scavenger, achieving ≥99.999% H₂ purity (≤1 ppm O₂, ≤1 ppm H₂O, ≤0.1 ppm total hydrocarbons)
  • Patented anti-backflow design prevents liquid ingress into the electrolyzer or connected instruments—even during sudden pressure drops or shutdown
  • Overpressure protection circuitry with mechanical relief valve (set at 0.45 MPa) and electronic cut-off at 0.42 MPa
  • Thermally regulated electrolytic cell maintains constant operating temperature (±0.5 °C), enhancing efficiency reproducibility and reducing thermal stress on catalyst layers
  • Low power draw (150 W nominal) and silent operation (<45 dB(A)) suitable for benchtop deployment in shared lab environments

Sample Compatibility & Compliance

The XYH-300 is compatible with all major GC manufacturers’ carrier-gas inlets (Agilent, Thermo Fisher, Shimadzu, PerkinElmer) and supports both split/splitless injectors and microfluidic ECD/TCD/FID detectors. Its gas delivery profile meets ASTM D7217–22 requirements for hydrogen purity in chromatographic carrier applications. The unit complies with IEC 61010-1:2010 safety standards for electrical equipment for measurement, control, and laboratory use. While not certified to ATEX or IECEx for hazardous area installation, it includes internal hydrogen sensors (0–100% LEL) and automatic shutdown logic if ambient H₂ concentration exceeds 1% vol. Documentation supports GLP/GMP traceability: full audit trail of runtime hours, pressure logs, and error codes is stored onboard and exportable via USB.

Software & Data Management

The XYH-300 operates in standalone mode with front-panel LED display and tactile push-button interface—no driver installation or PC dependency required. For integration into centralized lab infrastructure, optional RS-232/USB-C digital interface enables remote monitoring of flow rate, outlet pressure, cell temperature, and cumulative runtime via ASCII command protocol. All operational parameters are timestamped and retained in non-volatile memory for ≥12 months. Data exports conform to CSV format and are compatible with LabVantage, STAR, and OpenLab CDS for inclusion in instrument qualification records (IQ/OQ/PQ). Firmware updates are delivered via signed .bin files to ensure integrity and traceability per FDA 21 CFR Part 11 Annex 11 principles.

Applications

  • Carrier gas for capillary GC and GC-MS systems requiring high-purity, low-moisture hydrogen
  • Fuel gas for flame ionization detectors (FID) and flame photometric detectors (FPD)
  • Reductant gas in hydride generation atomic absorption spectroscopy (HG-AAS)
  • Blank gas in residual solvent analysis and polymer degradation studies
  • Calibration gas generator in environmental air monitoring labs where cylinder logistics are constrained
  • Research-scale hydrogenation support in catalysis labs using flow reactors (when paired with mass-flow controllers)

FAQ

What type of water must be used?
Deionized water with resistivity ≥18.2 MΩ·cm and total organic carbon (TOC) < 5 ppb is mandatory. Tap water, distilled water without post-treatment, or water from non-certified purification systems will cause rapid catalyst fouling and void warranty.
Can the XYH-300 supply multiple GCs simultaneously?
Yes—provided total combined flow demand remains within 0–300 mL/min and backpressure across the manifold does not exceed 0.35 MPa. Use of stainless steel distribution manifolds with individual needle valves is recommended for balanced allocation.
How often does the electrolyzer require servicing?
Under normal operation (8 h/day, 5 days/week), no scheduled maintenance is needed for the first 36 months. After 3 years, catalyst activity verification via polarization curve analysis is advised; replacement electrolyzer modules are available with serialized calibration certificates.
Is the hydrogen output suitable for use with palladium membrane purifiers?
Yes—the 99.999% base purity and sub-ppm moisture/oxygen content meet inlet specifications for commercial Pd-diffusion purifiers (e.g., VICI Metronics Ultra-Pure series), enabling further refinement to 99.99999% when required.
Does the unit include documentation for regulatory audits?
Yes—each unit ships with Factory Acceptance Test (FAT) report, Certificate of Conformance (CoC), material traceability for all wetted parts (EN 10204 3.1), and electronic IQ/OQ templates aligned with ISO/IEC 17025 and USP guidelines.