Chu Ding Technology XYA-5000G Oil-Free Air Generator for GC Carrier & Instrument Air Supply

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Chu Ding Technology
Origin Shanghai, China
Manufacturer Type Authorized Distributor
Model XYA-5000G
Output Flow Range 0–5000 mL/min
Output Pressure Range 0–200 psi (0–1.38 MPa)
Hydrocarbon Content <0.1 ppm (v/v)
Input Pressure Range 0–0.6 MPa
Operating Ambient Temperature 0–40 °C
Relative Humidity <85% RH
Power Supply 220 V ±10%, 50 Hz ±5%
Inlet Temperature Control Range 0–80 °C
Ramp Rate (Heating) 20 °C/min
Cool-down Rate 10 °C/min
Injector Max Temp 100 °C
Injector Pressure Setpoint Range 0–9 psi
Total Injector Flow Setpoint Range 0–5000 mL/min

Overview

The Chu Ding Technology XYA-5000G Oil-Free Air Generator is a laboratory-grade, high-purity compressed air source engineered specifically for gas chromatography (GC) systems and auxiliary instrumentation requiring clean, dry, hydrocarbon-free air. Unlike conventional oil-lubricated compressors, the XYA-5000G integrates a certified进口 (imported) oil-free scroll compressor—ensuring zero risk of oil carryover into sensitive GC pneumatic circuits, detector gas supplies (e.g., FID, NPD), or sample introduction pathways. Its core function is to generate instrument-grade air meeting ASTM D6299 and ISO 8573-1 Class 1.2.1 requirements for particulate, moisture, and hydrocarbon content. The system operates on ambient air intake, conditioning it through multi-stage filtration, catalytic hydrocarbon removal (XY-A adsorption module), stainless-steel pressure regulation, and precision flow control—delivering stable, repeatable output across the full 0–5000 mL/min range with pressure control up to 200 psi.

Key Features

  • Imported oil-free scroll compressor: Eliminates lubricant contamination, extends service life, and ensures long-term stability in GC carrier and detector gas applications.
  • Integrated XY-A hydrocarbon removal module: Catalytically adsorbs and decomposes volatile organic compounds (VOCs), esters, and trace hydrocarbons to <0.1 ppm (v/v), critical for low-background FID operation and method robustness.
  • Electropolished stainless-steel gas path: All wetted components—including tubing, regulators, and the internal 5 L storage tank—are constructed from 316L stainless steel and electropolished to Ra <0.4 µm, minimizing surface adsorption and corrosion-induced particulates.
  • Dual-stage filtration and pressure stabilization: Comprises pre-filter (coalescing), activated carbon + molecular sieve bed, and two independent stainless-steel pressure regulators delivering ±0.5 psi pressure accuracy under dynamic load conditions.
  • Auto-drain stainless-steel reservoir: Equipped with timed electronic condensate ejection to prevent rust formation and eliminate manual draining—critical for maintaining ISO 8573-1 Class 2 moisture compliance.
  • Low-noise architecture (<52 dB[A] at 1 m): Optimized acoustic enclosure and vibration-damped mounting enable seamless integration into shared analytical labs without acoustic interference.
  • Intelligent low-pressure start-up circuit: Reduces inrush current and mechanical stress on the compressor motor, improving MTBF (mean time between failures) by ≥40% versus standard start configurations.

Sample Compatibility & Compliance

The XYA-5000G is compatible with all major GC platforms—including Agilent 8890/8860, Thermo Scientific TRACE 1300/1600, Shimadzu GC-2030, and PerkinElmer Clarus series—as well as auxiliary instruments requiring clean air: nitrogen generators (membrane or PSA), autosamplers, purge-and-trap concentrators, and flame photometric detectors. It meets ISO 8573-1:2010 Class 1.2.1 (solid particles ≤0.1 µm, dew point ≤−40 °C, hydrocarbons ≤0.1 ppm), supports GLP/GMP-compliant environments via optional audit trail logging (when paired with Chu Ding’s CD-Link software), and conforms to IEC 61010-1 safety standards for laboratory equipment. Its pressure and flow stability are validated per ASTM E260-22 Annex A1 for GC carrier gas performance.

Software & Data Management

While the XYA-5000G operates as a standalone hardware unit, it supports digital integration via optional RS-232/USB interface and Chu Ding’s CD-Link v3.2 software suite. This enables real-time monitoring of outlet pressure, flow rate, compressor runtime, filter saturation status, and temperature diagnostics. Data logs are timestamped and exportable in CSV format for QC record retention. When deployed in regulated environments (e.g., pharmaceutical QC labs), the software optionally complies with FDA 21 CFR Part 11 requirements—including electronic signatures, role-based access control, and immutable audit trails—for full traceability during method validation and routine operation.

Applications

  • Primary carrier gas supply for packed and capillary GC columns where helium or hydrogen alternatives are used.
  • FID and NPD detector support gas (air for flame combustion and oxidizer).
  • Actuation air for pneumatic GC valves, pressure-programmed injectors, and backflush systems.
  • Instrument purge air for optical cells, detector housings, and mass spectrometer ion sources.
  • Lab-wide utility air for non-critical tasks—provided downstream filtration is added per application-specific purity needs.

FAQ

What is the maximum continuous operating pressure and flow specification?
The XYA-5000G delivers up to 5000 mL/min at pressures up to 200 psi (1.38 MPa) with sustained stability; derating is not required below 4000 mL/min at full pressure.
Does the unit require periodic replacement of filters or catalysts?
Yes—the XY-A hydrocarbon removal cartridge requires replacement every 12 months or after 3000 hours of operation; the coalescing pre-filter is rated for 6 months under typical lab conditions (ISO 8573-1 Class 4 inlet air).
Can this generator be used as a stand-alone air compressor for non-GC applications?
It is optimized for analytical instrumentation; general-purpose compressed air tools or spray systems are not supported due to flow/pressure duty-cycle limitations and lack of industrial-grade thermal protection.
Is the output air suitable for use with electron capture detectors (ECD)?
No—ECD requires ultra-high-purity nitrogen or argon/methane mixtures; the XYA-5000G is not designed for ECD carrier gas and does not meet the sub-ppb electronegative impurity specifications required.
How is compliance with ISO 8573-1 verified upon installation?
Chu Ding provides a factory calibration certificate (traceable to NIST standards) covering hydrocarbon, moisture, and particulate testing; end-users may perform on-site verification using ISO-certified portable analyzers (e.g., Parker Balston 7000 series).