Empowering Scientific Discovery

JRY-Z08 Fully Automatic Inversion Oscillator for Extraction and Homogenization

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand JRY
Origin Hunan, China
Manufacturer Type Direct Manufacturer
Country of Origin China
Model JRY-Z08
Price Range USD 700–2,100 (FOB)
Rotational Speed 0–60 rpm (adjustable)
Oscillation Mode Horizontal Circular Motion
Amplitude 6 mm
Display Digital LED Speed & Time Readout
Temperature Control Range Ambient to 65 °C
Temperature Accuracy ±1 °C
Timer Range 0–24 h
Bidirectional Rotation Programmable Forward/Reverse/Hold Intervals
Sample Capacity 8 × 2 L Bottles
Construction Material Full Stainless Steel Housing
Motor Power 120 W
Power Supply 220 V, 50 Hz
Net Weight 65 kg
Compliance Designed per HJ 299–2007 & HJ 300–2007 (China EPA Standards)
Customization Available for non-standard bottle configurations and control logic

Overview

The JRY-Z08 Fully Automatic Inversion Oscillator is an engineered platform for standardized leaching extraction and homogeneous sample mixing in environmental solid waste analysis. It operates on the principle of controlled horizontal circular oscillation—mechanically inverting sample bottles along a fixed axis at programmable angular velocity and dwell time—to ensure reproducible mass transfer between solid matrices and leaching agents (e.g., sulfuric–nitric acid mixture or acetic acid buffer). Unlike vortex or orbital shakers, this device maintains consistent mechanical stress across all sample positions via synchronized bidirectional rotation, minimizing shear-induced particle fragmentation while maximizing solute diffusion kinetics. Its design directly supports regulatory compliance with China’s Ministry of Ecology and Environment standards HJ 299–2007 and HJ 300–2007, which define mandatory protocols for toxicity characteristic leaching procedure (TCLP)-equivalent testing of industrial sludge, contaminated soils, fly ash, and municipal solid waste residues.

Key Features

  • Programmable bidirectional oscillation: Independent configuration of forward duration, reverse duration, and pause intervals ensures precise replication of EPA-aligned leaching dynamics.
  • Integrated Peltier-assisted temperature regulation: Maintains chamber ambient-to-65 °C stability within ±1 °C tolerance—critical for pH-sensitive extractions where thermal drift alters metal speciation and organic acid dissociation.
  • Full stainless steel construction (AISI 304): Corrosion-resistant housing withstands prolonged exposure to aggressive leachates including 5% v/v HNO₃/H₂SO₄ and 0.11 M CH₃COOH/CH₃COONa buffer solutions.
  • Digital dual-display interface: Simultaneous real-time readout of rotational speed (rpm), elapsed time (h:min), and setpoint temperature (°C) with non-volatile memory retention after power interruption.
  • Sealed operational chamber with acrylic viewing window: Enables visual verification of bottle integrity and liquid meniscus without interrupting the extraction cycle—reducing contamination risk and operator exposure to volatile organics or acidic vapors.
  • Patented dual-axis drive coupling and vibration-damping base mount: Minimizes structural resonance transmission to laboratory benches, ensuring long-term metrological stability during extended 24-hour runs.

Sample Compatibility & Compliance

The JRY-Z08 accommodates eight standard 2 L EPA-style wide-mouth HDPE or borosilicate glass extraction bottles (diameter ≤110 mm, height ≤320 mm), secured via spring-loaded clamps with silicone gasket seals. It is validated for use with both aqueous and semi-aqueous leachants specified in HJ 299–2007 (sulfuric–nitric acid method) and HJ 300–2007 (acetic acid buffer method), including spiked reference materials such as NIST SRM 2710a (Montana Soil) and IAEA-375 (fly ash). While not certified to ISO/IEC 17025 or ASTM D5233, its operational parameters align with the mechanical performance criteria outlined in US EPA Method 1311 (TCLP) and EN 12457-4 (characterization of waste—leaching—up-flow percolation test). The unit supports GLP documentation workflows through timestamped parameter logging and user-accessible audit trails.

Software & Data Management

The oscillator includes embedded firmware with USB-C data export capability (CSV format), recording start time, target rpm, temperature setpoint, forward/reverse timing sequence, and end-of-cycle status flag. No proprietary software installation is required—data files are compatible with Excel, LabArchives, and ELN platforms supporting FDA 21 CFR Part 11-compliant electronic signatures when paired with institutional validation protocols. Optional RS-485 Modbus RTU interface enables integration into centralized laboratory automation systems for remote monitoring and batch-level metadata synchronization.

Applications

  • Toxicity characteristic leaching procedure (TCLP) simulation for RCRA-regulated waste classification
  • Heavy metal mobility assessment in contaminated sediments and mining tailings
  • Organic contaminant (PAHs, PCBs, pesticides) release profiling under controlled pH and redox conditions
  • Validation of stabilization/solidification treatment efficacy prior to landfill disposal
  • Method development for emerging contaminants (e.g., PFAS, microplastics) requiring low-shear, high-contact-time extraction
  • Academic research in geochemistry, environmental engineering, and soil science laboratories requiring ISO 5725-2 traceability

FAQ

What leaching standards does the JRY-Z08 support?
It is explicitly designed to meet the mechanical and temporal requirements of HJ 299–2007 and HJ 300–2007, and functionally compatible with US EPA Method 1311 and EN 12457-4.
Can the unit operate unattended for full 24-hour cycles?
Yes—programmable timer, thermal cut-off protection, and auto-shutdown upon completion ensure safe overnight operation.
Is calibration traceable to national metrology institutes?
While factory calibration is performed using NIST-traceable tachometers and PT100 probes, end-user calibration verification must follow internal SOPs per ISO/IEC 17025 Clause 6.5.
Are replacement parts available internationally?
Stainless steel clamps, silicone gaskets, and control board assemblies are stocked for global distribution; lead time is 4–6 weeks ex-warehouse Changsha.
Does it comply with electrical safety standards for export?
The unit meets IEC 61010-1:2010 for laboratory equipment and carries CE marking per EU Directive 2014/35/EU (LVD); UL/cUL listing requires local certification agency engagement.