JRY-HX Laboratory Drying Oven
| Brand | JRY |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JRY-HX |
| Instrument Type | General-Purpose Drying Oven |
| Temperature Fluctuation | ±0.3°C |
| External Dimensions (L×W×H) | 740 × 550 × 880 mm |
| Internal Chamber Dimensions (L×W×H) | 615 × 450 × 490 mm |
| Chamber Material | Stainless Steel (304) |
| Heating Method | Multi-Surface Radiant Heating |
| Temperature Range | RT+5°C to 400°C |
| Temperature Uniformity (at 150°C) | ±1.9°C |
| Heating Rate (to 150°C) | ≤20 min |
| Rated Power | 2.5 kW |
| Standard Shelving | 2 adjustable stainless steel trays (up to 5 optional) |
| Optional Configurations | Vacuum or inert atmosphere porting |
| Net Weight | 57 kg |
| Viewing Window Size | ≥250 × 350 mm |
| External Surface Temp (max operating) | <60°C |
| Safety Compliance | CE-marked electrical architecture, IEC 61010-1 compliant design |
Overview
The JRY-HX Laboratory Drying Oven is an engineered thermal processing system designed for precise, repeatable, and contamination-controlled drying, baking, annealing, and conditioning applications in research laboratories, quality control environments, and industrial R&D settings. It operates on the principle of convective and radiant heat transfer within a sealed, insulated chamber, delivering stable thermal profiles across its full operating range from ambient +5°C to 400°C. Its robust construction—featuring a seamless 304 stainless steel interior chamber and aluminum-coated exterior housing—ensures long-term resistance to corrosion, thermal cycling fatigue, and chemical exposure during routine use with solvents, biological residues, or mineral digestates. The oven’s multi-surface heating architecture minimizes thermal gradients, while its intelligent microprocessor-based controller maintains setpoint accuracy with ±0.3°C fluctuation at steady state (measured at 150°C), supporting method-critical workflows such as moisture content determination (per ASTM E1868 and ISO 712), pharmaceutical stability testing, polymer curing validation, and glassware sterilization protocols.
Key Features
- Full 304 stainless steel internal chamber with welded seams and rounded corners for easy cleaning and residue-free operation
- Multi-surface radiant heating elements embedded in side and bottom walls ensure rapid thermal response and uniform temperature distribution (±1.9°C uniformity at 150°C)
- High-visibility observation window (≥250 × 350 mm) with double-layer tempered glass and integrated anti-fog coating for real-time sample monitoring without door opening
- Digital PID controller with dual-display interface showing both setpoint and actual chamber temperature, elapsed/remaining timer, fan speed stage, and operational status indicators
- Efficient forced-air circulation system with adjustable-speed blower and optimized duct geometry to support consistent airflow—even during high-mass load conditions
- External surface temperature maintained below 60°C under full-load operation, complying with IEC 61010-1 touch-safety requirements
- Modular shelving system: two heavy-duty stainless steel trays included; up to five trays configurable for vertical sample stacking without compromising air exchange
- Optional vacuum or inert gas inlet/outlet ports (N₂, Ar) for oxygen-sensitive processes including catalyst activation, thin-film drying, and low-oxygen annealing
Sample Compatibility & Compliance
The JRY-HX accommodates a broad spectrum of sample formats—including Petri dishes, crucibles, beakers, glass vials, ceramic boats, and custom fixtures—within its 615 × 450 × 490 mm usable chamber volume. Its non-porous stainless steel interior prevents cross-contamination between runs and supports cleaning validation per GLP and GMP Annex 15 guidelines. The unit meets fundamental safety and electromagnetic compatibility standards aligned with CE marking directives (2014/30/EU and 2014/35/EU) and conforms to IEC 61010-1:2010 for laboratory electrical equipment. While not intrinsically rated for hazardous area use, it may be deployed in Class 10,000 cleanrooms when paired with HEPA-filtered exhaust routing. For regulated applications involving moisture loss assays (e.g., USP <731> Loss on Drying), the oven’s documented temperature stability and traceable calibration capability support audit readiness under FDA 21 CFR Part 11–enabled data logging systems (when integrated externally).
Software & Data Management
The JRY-HX features RS-485 communication interface (Modbus RTU protocol) for integration with third-party SCADA platforms or centralized lab information management systems (LIMS). When paired with optional external data loggers or PLC controllers, users can generate time-stamped temperature profiles with timestamped event markers (door open/close, setpoint change, alarm triggers), satisfying ALCOA+ data integrity principles. Though the base unit does not include onboard electronic signature or audit trail functionality, its analog/digital I/O signals are compatible with validated 21 CFR Part 11-compliant software suites used in pharmaceutical and clinical diagnostics labs. Calibration certificates traceable to NIM (National Institute of Metrology, China) or ISO/IEC 17025-accredited providers can be supplied upon request.
Applications
- Moisture content analysis in food, feed, soil, and pharmaceutical raw materials (ASTM D4442, ISO 4611)
- Thermal aging studies of polymers, elastomers, and composites per ASTM D573 and ISO 188
- Pre-drying of filter papers and gravimetric sampling media prior to particulate mass determination (EPA Method 201A)
- Protein denaturation and starch gelatinization kinetics in biochemical research
- Post-curing of printed circuit board laminates and encapsulated semiconductor assemblies
- Drying of botanical specimens, textile swatches, and ceramic green bodies under controlled humidity-deprived conditions
- Residue ashing support for EPA SW-846 Method 3010A and AOAC 990.19
- Conditioning of reference standards and calibration weights per ISO 5725 and EURACHEM guidelines
FAQ
What is the maximum recommended continuous operating temperature?
The JRY-HX is rated for continuous operation up to 400°C. Prolonged use above 350°C may reduce heater element service life and requires verification of gasket material compatibility.
Can the oven be calibrated internally without external equipment?
No. Internal calibration requires a certified reference thermometer (e.g., PT100 probe with ±0.1°C uncertainty) and documented procedure per ISO/IEC 17025. Factory calibration certificate is available as an option.
Is over-temperature protection standard or optional?
Yes—dual independent over-temperature cutoffs are built-in: a programmable digital limiter and a mechanical backup thermostat (cut-off at 420°C).
Does the unit support ramp-soak programming?
The base controller supports single-stage setpoint hold only. Multi-segment ramp-soak profiles require external programmable logic controller (PLC) integration via RS-485.
Are replacement shelves and door gaskets available as spare parts?
Yes. All consumable and wear components—including stainless steel trays, silicone door gaskets, and heating element assemblies—are stocked and available with documented part numbers and lead times.