Yuelian YL-8807 Tape Retentivity Tester

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Yuelian
Origin Guangdong, China
Model YL-8807
Test Stations 10 independent stations
Load per Station 1 kg (×10)
Timer Range 0 s to 999 h 59 min (sexagesimal, LCD display, battery-powered)
Test Plate Material Mirror-finish SUS#304 stainless steel
Dimensions (W×D×H) 87 × 25 × 69 cm
Weight 45 kg
Compliance GB/T 2792, GB/T 4851, PSTC-7, CNS 11888

Overview

The Yuelian YL-8807 Tape Retentivity Tester is an engineered mechanical testing system designed for standardized evaluation of pressure-sensitive adhesive (PSA) tape holding power under static load conditions. It operates on the principle of vertical shear retention: a defined length of tape is affixed to a highly polished stainless steel substrate (SUS#304), loaded with a precisely calibrated mass (1 kg per station), and monitored for time-to-failure—i.e., the duration until complete debonding occurs under constant stress. This method quantifies the viscoelastic resistance of the adhesive layer to creep deformation at ambient temperature (typically 23 ± 2 °C, 50 ± 5 % RH per ISO 291), providing objective, repeatable data essential for quality control in adhesive manufacturing, packaging R&D, and regulatory documentation. Unlike dynamic peel or tack testers, the YL-8807 focuses exclusively on long-term bond stability—a critical parameter for applications such as medical tapes, electrical insulation wraps, labeling films, and automotive trim adhesives.

Key Features

  • 10 independent test stations enabling parallel evaluation of multiple samples or formulations—significantly improving throughput and statistical robustness.
  • Self-contained, battery-powered LCD timers (0 s to 999 h 59 min) with sexagesimal display; no external power required during operation, ensuring uninterrupted timing even during facility outages.
  • Mirror-finish SUS#304 stainless steel test plates conforming to surface roughness requirements specified in GB/T 2792 and PSTC-7 (Ra ≤ 0.2 µm), minimizing interfacial variability.
  • Integrated glass storm door to eliminate air currents that could induce premature detachment or measurement drift—critical for achieving high inter-laboratory reproducibility.
  • Rigid structural frame with precision-machined load application arms ensures uniform force distribution across all 10 stations without cross-talk or mechanical interference.
  • Modular connector design allows rapid plate replacement and cleaning; each station features dedicated mechanical alignment to maintain consistent tape overlap geometry (25 mm width × 100 mm length per standard).

Sample Compatibility & Compliance

The YL-8807 accommodates standard PSA tape widths up to 25 mm and thicknesses up to 0.5 mm, including acrylic, rubber-based, silicone, and hot-melt formulations. Sample mounting follows strict conditioning protocols outlined in ISO 291 and ASTM D3330 prior to testing. The instrument fully supports international test standards including GB/T 2792 (China), GB/T 4851 (China), PSTC-7 (Pressure Sensitive Tape Council, USA), and CNS 11888 (Taiwan). While not inherently compliant with FDA 21 CFR Part 11, raw timer output data (time-to-failure per station) can be manually transcribed into validated LIMS or ELN systems supporting audit trails and electronic signatures—making it suitable for GLP environments when integrated into documented SOPs.

Software & Data Management

The YL-8807 is a hardware-only platform with no embedded firmware or digital connectivity. All timing data are displayed locally on individual LCD modules and retained upon detachment event. For traceable recordkeeping, users are advised to log results using paper-based test records or third-party digital capture tools (e.g., barcode-scanned entry into LabVantage or LabWare). To meet GMP documentation requirements, laboratories commonly pair the YL-8807 with calibrated stopwatch validation logs and periodic performance verification using NIST-traceable weights and certified reference tapes. Optional accessories—including calibration kits and certified test plates—are available through authorized Yuelian distributors.

Applications

  • Quality assurance of production batches against internal specifications or customer technical agreements.
  • Comparative screening of adhesive formulations during R&D—e.g., evaluating crosslinker concentration effects on creep resistance.
  • Stability assessment of tapes subjected to accelerated aging (post-aging retesting per ASTM D1000).
  • Supplier qualification where contractual hold-time thresholds exceed 72 hours (e.g., industrial masking tapes requiring >168 h retention).
  • Root cause analysis of field failures linked to insufficient cohesive strength or thermal softening.
  • Supporting regulatory submissions for Class I/II medical devices where adhesive durability is referenced in biocompatibility dossiers (ISO 10993-5).

FAQ

What environmental conditions must be maintained during testing?
Testing shall be conducted in a controlled environment at 23 ± 2 °C and 50 ± 5 % relative humidity per ISO 291 and GB/T 2918. Specimens must be conditioned for ≥2 h prior to application.
Can the YL-8807 be used for elevated-temperature hold testing?
No—the instrument lacks thermal control. For elevated-temperature evaluations (e.g., 40 °C or 60 °C), users must integrate it into an externally regulated environmental chamber while ensuring mechanical stability and cable management for timer visibility.
Is the 1 kg load adjustable?
No—the load is fixed at 1 kg per station per design compliance with GB/T 4851 and PSTC-7. Custom load configurations require modification outside manufacturer warranty scope.
How often should the stainless steel plates be cleaned and inspected?
Plates must be cleaned with isopropyl alcohol and lint-free wipes before each test series; surface scratches or contamination exceeding Ra > 0.3 µm require plate replacement to maintain standard conformance.
Does the YL-8807 include calibration certification?
The unit ships with a factory inspection report. Full metrological calibration—including load verification with Class M1 weights and timer accuracy validation against a traceable quartz chronometer—is the responsibility of the end-user’s QA department or accredited third-party lab.