Kanomax 3715-06 Remote Airborne Particle Counter
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3715-06 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Maximum Detectable Concentration | 2,000,000 counts/ft³ |
| Communication Protocols | RS-485, Modbus RTU/TCP/IP |
| Data Storage Capacity | 4,320 records |
| Internal Vacuum Pump Lifetime | 8,000 hours |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Storage Conditions | −10–50 °C, ≤95% RH (non-condensing) |
| Dimensions | 217 × 69 × 110 mm |
| Weight | 1.4 kg |
| Power Supply | DC 12–24 V / AC 100–240 V |
| Display | 4.3-inch capacitive touchscreen |
| Optional Sensors | Integrated temperature & humidity probe |
| Power Options | PoE, AC adapter, DC input, or external switch-mode power supply |
Overview
The Kanomax 3715-06 Remote Airborne Particle Counter is a high-reliability, ISO-compliant environmental monitoring instrument engineered for continuous, unattended operation in cleanroom validation, pharmaceutical manufacturing, semiconductor fabrication, and HVAC system performance verification. Utilizing a stable, low-noise laser diode light source and a precision-engineered optical sensing chamber, the 3715-06 applies the principle of light scattering to detect and size airborne particulates in real time. Its six-channel simultaneous counting capability—spanning 0.3 µm to 10.0 µm—enables comprehensive particle distribution profiling aligned with international cleanroom classification standards (ISO 14644-1, EU GMP Annex 1). Designed for permanent installation, the unit features an integrated vacuum pump with an 8,000-hour service life and supports remote configuration, data retrieval, and alarm triggering via industrial-grade communication protocols.
Key Features
- Simultaneous six-size-channel detection at 0.3, 0.5, 1.0, 3.0, 5.0, and 10.0 µm—with counting efficiency certified to ISO 21501-4 and JIS B 9921.
- Stable 2.83 L/min (0.1 CFM) volumetric flow rate maintained by a built-in, brushless vacuum pump—calibrated and traceable to NIST-traceable flow standards.
- Modular power architecture supporting PoE (IEEE 802.3af), AC 100–240 V, DC 12–24 V, and external switch-mode supplies—ideal for integration into diverse facility infrastructures.
- 4.3-inch capacitive touchscreen interface enabling local setup, real-time trend visualization, and manual sampling control without external software.
- Onboard data logging capacity of 4,320 timestamped records—including particle counts per channel, temperature, relative humidity (with optional probe), flow status, and alarm flags.
- Ruggedized aluminum alloy housing rated for long-term deployment in controlled environments; resistant to condensation, vibration, and ambient electromagnetic interference.
Sample Compatibility & Compliance
The 3715-06 is validated for use in ISO Class 3–8 cleanrooms and classified production areas where continuous environmental monitoring is mandated under FDA 21 CFR Part 11, EU Annex 11, and PIC/S guidance. It meets the metrological requirements for airborne particle instrumentation specified in ISO 21501-4 (Determination of particle size distribution—Light scattering single particle counter methods) and JIS B 9921. The device supports audit-ready data integrity through timestamped logs, configurable alarm thresholds (0–100% of limit), and addressable Modbus node identification (1–247). Optional temperature/humidity sensing enables correlated environmental parameter logging—critical for root-cause analysis during excursion investigations.
Software & Data Management
Data export is supported via USB mass storage mode or network transfer using Modbus TCP/IP, allowing seamless integration with SCADA systems, MES platforms, and centralized environmental monitoring systems (EMS). Logged records include full metadata: sampling start/stop time, duration, channel-specific counts, flow verification status, pump runtime, and sensor health indicators. Firmware updates are performed over-the-air or via microSD card—retaining all calibration and configuration settings. All communications are non-proprietary and fully compatible with third-party historian databases and compliance reporting tools used in regulated industries.
Applications
- Real-time cleanroom classification and re-certification per ISO 14644-1 and IEST-G-CC1002.
- Continuous monitoring of critical process zones in aseptic filling lines, isolators, and RABS.
- Filter integrity testing support through upstream/downstream particle trending.
- HVAC system commissioning, balancing, and fault diagnostics via spatial particle mapping networks.
- Environmental qualification of laboratory animal facilities and biosafety cabinets (BSCs).
- Supporting ISO/IEC 17025-accredited calibration laboratories requiring traceable, auditable particle measurement workflows.
FAQ
Does the 3715-06 require annual recalibration?
No scheduled annual recalibration is required; however, users must perform routine flow verification and zero-count checks per internal SOPs. Full factory recalibration is recommended every 24 months or after repair, using NIST-traceable reference aerosols.
Can multiple 3715-06 units be daisy-chained on a single RS-485 bus?
Yes—up to 32 units can be addressed on one RS-485 network using Modbus RTU, provided proper termination and biasing resistors are installed per EIA-485 specifications.
Is the internal pump suitable for high-static-pressure duct applications?
The integrated pump is optimized for ambient-pressure sampling and low-resistance inlet configurations. For duct-mounted installations with static pressure >50 Pa, an external booster pump is recommended.
How is data security handled when using Modbus TCP/IP?
Modbus TCP/IP operates at Layer 4 and does not natively encrypt payloads. Secure deployment requires network segmentation, firewall rules, and VLAN isolation—consistent with ISA/IEC 62443-3-3 recommendations for OT environments.
What documentation is supplied for regulatory submissions?
Standard delivery includes Factory Calibration Certificate (traceable to JCSS), ISO 21501-4 Conformance Statement, CE Declaration of Conformity, RoHS Compliance Report, and full user manual with traceability diagrams and maintenance log templates.