Empowering Scientific Discovery

Shenyang Keye Scientific Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
Model6006
Instrument TypeThermal Anemometer
Measurement Range0.01–20.0 m/s
Resolution0.01 m/s (0.01–9.99 m/s)
Accuracy±5% of reading (m/s)
Temperature Range−20 to +70 °C
Temperature Accuracy±1.0 °C
Relative Humidity Operating Range20–85% RH
Power Supply4 × AA batteries
Dimensions60 × 120 × 34 mm
Weight180 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
Instrument TypeHot-Wire Anemometer
Measurement Range0.01–20.0 m/s
Resolution0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s)
Accuracy±5% of reading (wind speed), ±1°C (temperature)
Operating Temperature−20–70°C (probe), 5–40°C (main unit)
Operating Humidity20–85% RH
Response Time<1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature)
Display FeaturesBattery level (4-segment), FAST/SLOW averaging (1 s / 5 s), unit toggle (m/s/°C ↔ fpm/°F), hold function
Probe DimensionsØ6.1 mm (Ø10.6 mm at tip) × 205 mm
cableØ3.3 mm × ~1.5 m
Main Unit Dimensions60 × 120 × 30 mm
Weight~180 g (including batteries)
ComplianceDesigned for ISO 7726-compliant thermal environment assessment, suitable for HVAC commissioning and indoor air quality (IAQ) surveys per ASHRAE Standard 111 and EN 13790
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
Model6710
Instrument TypePitot-static Air Flow Hood
Flow Range40–4300 m³/h
Accuracy±3% of reading ±10 m³/h
Temperature Range0–60 °C
Temperature Accuracy±0.5 °C
Humidity Range0–100 %RH
Humidity Accuracy±3 %RH (10–90 %RH)
Display3.5-inch color LCD with auto-rotation
Data Storage3,000 sets
Power4 × AA batteries (up to 9 h) or DC 5 V adapter
Weight~3.5 kg
Standard Hood Size610 × 610 mm
Optional Hood Sizes305×1220 mm, 500×500 mm, 610×1220 mm, 800×800 mm, 800×1100 mm, 915×610 mm, 915×915 mm, 1220×1220 mm, 1400×800 mm
Key FunctionsBackpressure compensation, transparent viewing window, real-time clock, battery level indicator, USB communication, RS-232 printer interface, data export and deletion
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginChina (Liaoning)
Model3000-0C+
Instrument TypeOnline Fit Testing System
Flow RateSampling Flow 100 cm³/min
Particle Size Range0.02–1.0 µm
Concentration Range0–100,000 particles/cm³
Fit Factor Calculation MethodDirect Cout/Cin Ratio
Test AgentIsopropanol or Ethanol (≥99.5% purity)
Display7-inch TFT color touchscreen
LanguagesEnglish, Japanese, Chinese, French, Spanish, Portuguese
Compliance StandardsOSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, HSE INDG479, GB 19083–2010, GB 2626–2019, GB/T 32610–2016
Data InterfaceUSB, Ethernet, Wi-Fi
Software CompatibilityWindows 7/8/10, .NET Framework 3.5
Report FormatMicrosoft Excel (.xlsx)
Operating Environment10–35 °C, 20–85% RH (non-condensing)
Storage Conditions−20–50 °C, 0–85% RH (non-condensing)
Power SupplyAC 110–240 V, 50/60 Hz
Dimensions208 × 117 × 262 mm (W×H×D)
Weight2.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
Model6006
Instrument TypeHot-Wire Anemometer
Measurement Range0.01–20.0 m/s
Resolution0.01 m/s (0–9.99 m/s), 0.1 m/s (10.0–20.0 m/s)
Accuracy±5% of reading (wind speed), ±1°C (temperature)
Operating Temperature−20–70°C (probe), 5–40°C (main unit)
Operating Humidity20–85% RH
Response Time<1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature)
DisplayDual-parameter (wind speed + temperature), selectable units (m/s/°C or fpm/°F), FAST/SLOW averaging, battery level indicator (4-segment), hold function
Probe DimensionsØ6.1 mm (Ø10.6 mm at tip) × 205 mm
CableØ3.3 mm × ~1.5 m
Main Unit Dimensions60 × 120 × 30 mm
Weight~180 g (including batteries)
ComplianceDesigned per JIS B 7554 and IEC 61260-1 Class 2 requirements for environmental air velocity instrumentation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginLiaoning, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
Model6720-DP
Measurement Range±2500 Pa
Accuracy Class0.01
MediumGas
Operating Temperature0–60 °C (non-condensing)
Differential Pressure Resolution0.001 Pa
Differential Pressure Accuracy±1.5% of reading ±0.25 Pa
Air Velocity Range (with Pitot Tube)0.15–40 m/s
Air Velocity Range (with Air Velocity Matrix)0.15–15 m/s
Air Velocity Accuracy±3% of reading ±0.05 m/s (>0.25 m/s)
Air Velocity Resolution0.01 m/s
Display4.3-inch full-color touchscreen
Data Storage8,000 readings (instrument), 10,000 readings (mobile app)
Power4 × AA batteries (~14 h continuous operation), DC 5 V input
Weight~390 g
CommunicationBluetooth 4.2, USB data export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
Model6236
Instrument TypeHandheld Integrating Sound Level Meter
Frequency Range20–8,000 Hz
Measurement Ranges28–130 dB(A), 30–130 dB(C), 38–130 dB(Z)
Self-Noise0.1 dB
Accuracy±0.1 dB
Maximum Measurement Duration199 h 59 min 59 s
MicrophoneType 7146NL (Sensitivity: −28 dB re 1 V/Pa
Standalone calibration−23 dB)
ComplianceIEC 61672-1:2013 Class 1, ANSI S1.4-1983 Type 1
Time WeightingFast / Slow
DisplayBacklit LCD with Analog Bar Graph
Power Supply4 × AA batteries (≈9 h operation) or AC adapter
Dimensions & Weight86 × 285 × 46 mm, ≈450 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
Model3910+
Flow Rate50 L/min
Flow Accuracy< ±1 particle per 5 min
Timing Accuracy< ±1 s over 6-min sampling
Repeatability≤ ±10% FS
Size Distribution Error≤ ±30%
Indication Error< ±30% FS
Particle Size Channels0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm
Counting Efficiency50 ± 20% @ 0.3 µm (ISO 21501-4 compliant)
Max Concentration300,000 particles/ft³
Resolution<15% @ 0.3 µm (ISO 21501-4)
Zero CountCompliant with JIS B 9921
Data Storage10,000 sample records (expandable via USB drive)
Display6.4-inch full-color touchscreen
ComplianceISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, JJF 1190–2008, EU GMP Annex 1, US FDA 21 CFR Part 11 (audit trail & electronic signature support)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginLiaoning, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelKA25
Instrument TypeThermal Anemometer
Resolution±(3% of reading + 0.03 m/s)
Measurement Range0.01–20.0 m/s
Accuracy±(3% of reading + 0.03 m/s)
Operating Temperature (Probe)−20 to +70 °C
Temperature Accuracy±0.5 °C (at v > 0.5 m/s)
Temperature Resolution0.1 °C
Air Velocity Response Time~1 s (90% response at 1 m/s)
Temperature Response Time~30 s (90% response at 1 m/s)
Pipe Types SupportedRectangular and Circular
Dimension Input Range0.1–255.0 cm
Air Volume Resolution1 m³/h
Data Hold FunctionYes
Time Constant Options1 s / 5 s / 10 s / 20 s
DisplayTriple-level backlight LCD
Power Supply4 × AA alkaline batteries
Battery LifeApprox. 15 hours (1 m/s, 20 °C)
Body Dimensions200 × 85 × 40 mm
Probe DimensionsΦ6 mm (sensor) / Φ14 mm (handle) × 294–1060 mm (telescoping & bendable)
Cable Length2000 mm
Operating Environment (Body)5–40 °C
Storage Temperature−20 to +60 °C
Weight~220 g (without batteries)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
Model3720-06
Instrument TypeOnline Particle Counter
Flow Rate28.3 L/min (1.0 CFM)
Detectable Particle Sizes0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm (2–4 sizes configurable at factory)
Light SourceLong-life Class II laser diode
Counting EfficiencyCompliant with ISO 21501-4 and JIS B9921
Max. Concentration1,000,000 counts/ft³
Data Storage5,000 full measurement records + 4,320 buffered samples
Output InterfacesEthernet, RS-485, 4–20 mA analog, Modbus RTU/TCP
Power SupplyDC 15–28 V, PoE (IEEE 802.3af), or AC 100–240 V
Housing Material316 stainless steel with VHP- and alcohol vapor-resistant sealed enclosure
Operating Environment10–30 °C, 20–85% RH (non-condensing)
Dimensions180 × 110 × 19 mm
Weight4.0 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
Model3887D
Instrument TypeHandheld Particle Counter
Flow Rate2.83 L/min (0.1 cfm)
Flow Accuracy< ±1 particle per 5 min
Timing Accuracy±1 s within 6-min sampling
Repeatability≤ ±10% FS
Size Distribution Error≤ ±30%
Indication Error≤ ±30% FS
Particle Size Channels0.3, 0.5, 1.0, 3.0, 5.0 µm
Sampling Duration10 sec – 99 min 59 sec
Data Storage Capacity7,000 records
Power Supply4×AA Ni-MH rechargeable batteries or AC adapter (100–240 V AC)
Dimensions108(W) × 68(D) × 196(H) mm
Weight~680 g (without batteries)
Compliance StandardsISO 14644-1, GB/T 16292–2010, China GMP (2010) Annex 1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
Model6006
Instrument TypeThermal Anemometer
Measurement Range0.01–20.0 m/s
Resolution0.01 m/s (0.01–9.99 m/s)
Accuracy±5% of reading (wind speed)
Operating Temperature−20 to +70 °C
Operating Humidity20–85% RH
Power Supply4 × AA batteries
Dimensions60 × 120 × 34 mm
Weight180 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
Instrument TypeThermal Anemometer
Resolution0.01 m/s
Accuracy±2% of reading
Operating Temperature Range−20 °C to +70 °C
Operating Relative Humidity Range2.0–98.0% RH
Probe Compatibility8 interchangeable thermal anemometry probes (hot-wire/hot-film)
Data Storage CapacityUp to 20,000 measurement records
Built-in CalculationsReal-time air volume (m³/h or CFM) via user-defined duct geometry (rectangular, circular, oval cross-sections with dimensional input)
On-device StatisticsMin/Max/Avg values with hold function
Standard Accessories2 m probe cable × 1, carrying case × 1, operator manual
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginUSA
Manufacturer TypeAuthorized Distributor
Country of OriginImported
Model6236
PriceUSD 2,950 (FOB)
MicrophoneType 7146NL (Sensitivity: −28 dB re 1 V/Pa, Standalone calibration: −23 dB)
Measurement RangeA-weighted 28–130 dB, Z-weighted 39–130 dB
Frequency WeightingA, C, Z
Time WeightingFast, Slow
ConformanceIEC 61672-1:2013 Class 1, ANSI S1.4-1983 Type 1
Power Supply4 × AA alkaline batteries (≈9 h operation) or optional AC adapter
Dimensions86 × 285 × 46 mm
Weight≈450 g
DisplayBacklit LCD with real-time analog bar graph
Measurement ModesInstantaneous SPL, Equivalent Continuous Sound Level (Leq), Single-Event Noise (SEL), Lmax, Lmin, Time-Weighted Average (Lx%)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
Model3950
Flow Rate2.83 L/min (0.1 CFM)
Flow Accuracy±5%
Timing Accuracy±1 s per 6 min
Repeatability±5%
Size Resolution≤15% (vs. 0.3 µm PSL)
Counting Efficiency50±20% at 0.1 µm, 100±10% at 0.15–0.2 µm PSL
Max Concentration10⁷ particles/m³
Particle Channels0.1 µm & 0.3 µm
ComplianceJIS B9921 & ISO 21501-4
Display4.3" color TFT touchscreen
InterfaceUSB Host/Device, Ethernet, RS-485
Data Storage10,000 records (CSV)
Operating Environment15–35°C, 0–85% RH (non-condensing)
Dimensions150 × 163 × 228 mm
Weight3.4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
Model6850
Differential Pressure Range–2500 to +2500 Pa
Accuracy±0.5% of reading ±1 Pa
Resolution0.1 Pa
Air Velocity Range0.20–60.0 m/s
Velocity Accuracy±1.5% of reading (at 10.0 m/s)
Velocity Resolution0.01 m/s
Airflow Volume Range0–999999 m³/h
Volume Resolution1 m³/h
Operating Temperature0–60 °C (non-condensing)
Storage Temperature–20–70 °C (non-condensing)
Power Supply4 × AA batteries or DC 5 V AC adapter
Battery Life>15 hours
Weight (incl. batteries)~360 g
Data Storage Capacity10,000 records
Data ExportUSB flash drive support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
Instrument TypeThermal Anemometer
Model6113
Resolution0.1 m/s
Measurement Range0.1–50.0 m/s
Accuracy±(3% of reading ± 0.1) m/s
Operating Temperature0–100 °C
Operating Humidity Range5–80 %RH (with humidity-related velocity error ±(5% of reading + 0.1) m/s)
DisplayLarge LCD
InterfaceStandard RS-232C
Optional OutputAnalog output (4–20 mA or 0–5 V, configurable)
Probe InterchangeabilityYes
Data StorageOn-unit storage for simultaneous wind speed, air temperature, and differential pressure readings
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginLiaoning, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDALT6900
Flow Range36–640 m³/h (nozzle range: 4–36 m³/h)
Accuracy±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure)
Resolution0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure)
Static Pressure Range±2500 Pa
Temperature Range0–60 °C
Atmospheric Pressure Range70–130 kPa
Power SupplyDALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A
DALT6900-1E220–240 V, 1-phase, 50/60 Hz, 10 A
Weight~72 kg
Dimensions540 × 500 × 1200 mm
Data Storage1000 test records
Display4.7-inch color LCD touchscreen
Compliance StandardsEN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
Model6006
Instrument TypeThermal Anemometer
Measurement Range0.01–20.0 m/s
Resolution0.01 m/s (0–9.99 m/s), 0.1 m/s (10.0–20.0 m/s)
Accuracy±5% of reading (wind speed), ±1°C (temperature)
Operating Temperature−20–70°C (probe), 5–40°C (main unit)
Operating Humidity20–85% RH
Response Time<1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature)
DisplayDual-parameter (wind speed & temperature), 4-segment battery indicator, FAST/SLOW averaging (1 s / 5 s), unit toggle (m/s/°C ↔ fpm/°F), hold function
Probe DimensionsØ6.1 mm (Ø10.6 mm at tip) × 205 mm
cableØ3.3 mm × ~1.5 m
Main Unit Dimensions60 × 120 × 30 mm
Weight~180 g (including batteries)
Storage Temperature−10–50°C
AccessoriesInstruction manual, carrying case
Optional AccessoriesExtension rod, replacement probe
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
ModelKA33
Instrument TypeThermal Anemometer
Measurement Range0.01–50.0 m/s
Resolution0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s)
Accuracy±2% FS
Operating Temperature−20 to +100 °C
Operating Humidity2.0–98.0% RH
Display3.5-inch true-color LCD with dual digital/analog readout
Power Supply6 V DC (4 × AA batteries)
Battery LifeExtended by 25% vs. predecessor KA22/31
Probe CompatibilityInterchangeable modular probes with extendable/retractable shaft
Data FunctionsMax/Min/Avg wind speed, threshold-based pass/fail judgment mode, real-time temperature & differential pressure measurement
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
ModelKANOMAX 3443
Measurement PrincipleOptical Light Scattering
Particle Size Range0.1–10 µm
Resolution0.01 mg/m³
Accuracy±10%
Relative Error≤±2%
Data Storage Capacity500 records
Sampling IntervalConfigurable from 10 to 3600 seconds (default options: 24 s, 120 s)
Communication InterfaceRS-232C
Safety ClassificationNon-explosion-proof
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
Model6113
Instrument TypeThermal Anemometer
Velocity Range0.1–50.0 m/s
Velocity Resolution0.1 m/s
Velocity Accuracy±(3% of reading + 0.1) m/s
Temperature Range0–100 °C
Temperature Accuracy±1 °C
Pressure Range–5 to +5 kPa
Pressure Accuracy±(3% of reading + 0.01) kPa
Humidity Operating Range5–80 %RH (for velocity measurement accuracy specification)
Communication InterfaceRS-232C
Data Storage Capacity100 measurement sets
Statistical FunctionsMax/Min/Average
Built-in Thermal PrinterYes
Analog Output0–1 V
Power Supply6 × AA batteries
Dimensions210 × 120 × 133 mm
Weight1.0 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
Model3715-06D
Flow Rate2.83 L/min (0.1 CFM)
Particle Size Channels0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm
Light SourceLong-life Laser Diode
Counting EfficiencyCompliant with ISO 21501-4 and JIS B 9921
Maximum Detectable Concentration2,000,000 counts/ft³
Communication ProtocolsRS-485, Modbus RTU/TCP/IP
Data Storage Capacity4,320 records
Power OptionsDC 12–24 V, AC 100–240 V, PoE, or DC battery
Operating Temperature10–30 °C
Operating Humidity20–85% RH (non-condensing)
Dimensions217 × 69 × 110 mm
Weight1.4 kg
Vacuum Pump Lifetime8,000 h
MTBF≥10 years
Warranty3 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
Model3950-00
Flow Rate2.83 L/min (0.1 CFM)
Flow Accuracy±5%
Timing Accuracy±1 s per 6 min
Repeatability±5%
Size Distribution Error±15%
Indication Error±30%
Particle Channels0.1 μm & 0.3 μm
Detection PrincipleLight Scattering
ComplianceJIS B9921 & ISO 21501-4
Max Concentration10⁷ particles/m³
Counting Efficiency50±20% @ 0.1 μm PSL, 100±10% @ 0.15–0.2 μm PSL
False Count Rate<1 count/35 min
Size Resolution≤15% (vs. 0.3 μm PSL)
Display4.3″ Color TFT Touchscreen
CommunicationRS-485, Ethernet (10/100BASE-T), USB Host/Device
Data StorageInternal CSV (up to 10,000 records)
Operating Environment15–35 °C, 0–85% RH (non-condensing)
Dimensions150 × 163 × 228 mm
Weight3.4 kg