Empowering Scientific Discovery

HUANKONG GHK-1302 Dual-Channel VOC Sampler with Thermal-Regulated Adsorption Tube Support

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HUANKONG
Origin Shandong, China
Manufacturer Type Direct Manufacturer
Instrument Type 24-Hour Constant-Temperature & Constant-Flow Gas Sampler
Configuration Dual-Channel Gas Sampler
Flow Range 0.010–0.300 L/min (field-selectable)
Mass Flow Meter Accuracy ≥ ±2.5% FS

Overview

The HUANKONG GHK-1302 Dual-Channel VOC Sampler is an engineered solution for compliant, field-deployable collection of volatile organic compounds (VOCs) from ambient air and stationary source emissions. Designed specifically for adsorption tube-based sampling workflows, it operates on the principle of controlled volumetric aspiration through sorbent-packed tubes—enabling quantitative capture of target analytes including total VOCs (TVOCs), benzene, toluene, xylenes (BTX), aldehydes, and amide-class compounds. Its architecture adheres to the fundamental requirements of standardized thermal desorption–gas chromatography–mass spectrometry (TD-GC-MS) and GC-FID methodologies. The instrument maintains stable flow and temperature conditions across extended sampling durations (up to 24 hours), ensuring adherence to U.S. EPA Method TO-17, ISO 16017-1, and key Chinese environmental standards—including HJ 644–2013, HJ 583–2010, HJ 584–2010, HJ 734–2014, and HJ 801–2016—thereby supporting legally defensible data generation in regulatory monitoring, industrial hygiene, and emission inventory programs.

Key Features

  • Dual independent sampling channels with fully programmable start/stop timing, real-time flow monitoring, and asynchronous operation—enabling parallel sampling at different flow rates or time windows
  • Brushless DC vacuum pump with high load tolerance and >10,000-hour service life; optimized for low acoustic emission (<45 dB(A)) in field environments
  • High-stability mass flow sensors calibrated to NIST-traceable standards, delivering repeatability ≤±1.5% RSD over full operational range (0.010–0.300 L/min)
  • Integrated rechargeable Li-ion battery pack supporting ≥8 hours of continuous dual-channel operation at 0.2 L/min per channel
  • Two-stage particulate filtration system (2 µm sintered stainless steel + hydrophobic membrane) upstream of flow sensors and pump—minimizing maintenance and extending calibration stability
  • Non-volatile memory with automatic power-fail recovery: all active sampling parameters, timestamps, and cumulative flow data retained during unexpected shutdown
  • Modular thermal management options: optional refrigerated sampling chamber (0–5 °C) for cold-trap adsorption tubes; optional heated sampling lines with PID-controlled temperature uniformity ±2 °C
  • Expandable configuration support: serial connection of backup adsorption tubes for breakthrough validation; PTFE-lined sample probes to minimize analyte adsorption and memory effects

Sample Compatibility & Compliance

The GHK-1302 supports standard 6 mm OD × 90 mm adsorption tubes (e.g., Tenax TA, Carbopack B/C, Graphitized Carbon Black, and mixed-bed sorbents) as specified in HJ 644–2013 and ISO 16017-1. It accommodates both ambient air (via tripod-mounted passive inlet) and stack/duct sampling (with optional heated probe and pitot-static interface). All firmware and hardware design elements align with GLP-compliant data integrity principles: audit-trail-capable event logging, user-access levels, and tamper-evident parameter storage. While not pre-certified to IEC 61000-6-2/4 or ATEX, its electrical safety conforms to GB 4793.1–2019 (equivalent to IEC 61010-1), and electromagnetic compatibility meets Class B limits per GB/T 18268.1–2010.

Software & Data Management

Onboard 128 MB flash memory stores >500 sampling records per channel—including date/time stamps, setpoint vs. actual flow profiles, battery voltage history, temperature logs (when equipped), and error codes. Data export is supported via USB-C or Bluetooth 5.0 (BLE) to Windows/macOS platforms using HUANKONG’s PC Utility v3.2—software that generates CSV- and PDF-formatted reports compliant with QA/QC documentation requirements. Optional Bluetooth thermal printer integration enables immediate hardcopy generation of field verification sheets. Firmware updates are delivered via signed binary packages with SHA-256 checksum validation.

Applications

  • Ambient air quality monitoring networks targeting BTX, C2–C12 aliphatics, and oxygenated VOCs
  • Compliance testing of fixed emission sources per China’s “Standard for Emission of Volatile Organic Compounds from Industrial Enterprises” (GB 37822–2019)
  • Workplace exposure assessment in petrochemical, pharmaceutical, and coating manufacturing facilities
  • Method validation and laboratory intercomparison studies requiring traceable, multi-point sampling
  • Indoor air quality investigations in schools, hospitals, and newly renovated buildings
  • Research-grade sampling for atmospheric chemistry modeling and source apportionment studies

FAQ

Does the GHK-1302 meet U.S. EPA or EU regulatory requirements for VOC sampling?
It complies with technical performance criteria aligned with EPA Method TO-17 and EN 13649–2 for sampling efficiency and flow stability, though formal EPA certification requires third-party validation under local jurisdictional protocols.
Can the unit operate unattended for 24 hours?
Yes—when powered by AC mains and configured for single-channel operation at ≤0.15 L/min, it sustains precise constant-flow sampling for 24 hours; dual-channel operation at rated flow requires external power or periodic battery recharging.
Is calibration traceable to national standards?
Factory calibration uses NIST-traceable dry calibrators; users may perform field verification with primary-standard bubble meters or electronic calibrators meeting ISO 4031 requirements.
What sorbent tube types are validated for use?
Tenax TA, Carbopack X, and multi-bed tubes (e.g., Carbograph 1TD/Carbopack B) have been verified per HJ 644–2013 protocols; custom sorbent configurations require method-specific validation.
How is data integrity ensured during long-term deployment?
All critical operational parameters are logged at 10-second intervals with write-once memory architecture; timestamping is synchronized via internal RTC with ±2 sec/month drift specification.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0