Empowering Scientific Discovery

HUANKONG GHD-5001 Multifunctional Gas Autosampler for Summa Canisters and Tedlar Bags

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HUANKONG
Origin Shandong, China
Manufacturer Type Direct Manufacturer
Instrument Type Gas Chromatography Autosampler
Maximum Sample Capacity 16 positions
Motion Control Fully Automated
Syringe Wash Capability Unlimited wash cycles
Repeat Injection Capability Unlimited injections per sequence
Purge Function Not integrated
View Window Not included

Overview

The HUANKONG GHD-5001 Multifunctional Gas Autosampler is an engineered solution for high-throughput, unattended introduction of volatile organic compound (VOC) samples stored in evacuated Summa canisters and Tedlar® gas sampling bags. Designed specifically for ambient air, industrial emission, and indoor air quality monitoring workflows, the system operates on a pressure-driven gas transfer principle—leveraging precise electronic pressure control and calibrated flow paths to deliver reproducible sample volumes into pre-concentrators or directly into gas chromatography (GC) or GC–mass spectrometry (GC–MS) systems. Its architecture supports full compliance with U.S. EPA Method TO-14A, TO-15, and Compendium Method TO-11A, as well as Chinese national standards HJ 759–2015 and HJ 1078–2019 for ambient air VOC analysis. The autosampler does not rely on syringe-based liquid-phase injection; instead, it maintains integrity of gaseous analytes through inert, passivated flow paths—eliminating adsorption losses and memory effects common in non-silanized systems.

Key Features

  • Fully automated 16-position carousel accommodating standard 6-L, 3-L, 1-L, and 0.5-L Summa canisters, plus flexible-volume Tedlar bags (with optional bag holder kits)
  • Integrated electronic pressure regulation and real-time flow monitoring for accurate, volume-controlled sample transfer
  • Entire gas pathway—including valves, fittings, and transfer lines—treated with dimethylchlorosilane (DMCS) silanization to minimize surface reactivity and analyte adsorption
  • Large-format LCD touchscreen interface with intuitive icon-driven navigation, supporting method setup, sequence programming, and real-time status feedback
  • Modular I/O architecture enabling seamless integration with commercial thermal desorption pre-concentrators (e.g., Markes UNITY, Gerstel MPS, Thermo TriPlus) via TTL/RS-232/RS-485 protocols
  • Unattended operation with programmable start times, fixed-volume injections (e.g., 100 mL, 250 mL), time-based sequences, and multi-injection repeat logic
  • Scalable deployment: multiple GHD-5001 units can be daisy-chained under centralized software control for extended batch processing

Sample Compatibility & Compliance

The GHD-5001 is validated for use with electropolished stainless-steel Summa canisters (NIST-traceable calibration compatible) and low-diffusion fluorinated ethylene propylene (FEP) Tedlar bags. All wetted materials meet USP Class VI and ASTM F2473 requirements for VOC stability. The system supports audit-ready operation under GLP and ISO/IEC 17025 frameworks: instrument logs record timestamped events (valve actuation, pressure stabilization, injection completion), and method files are digitally signed and version-controlled. While the unit itself does not include built-in purge functionality, its open architecture permits external purge gas integration via third-party mass flow controllers when required by method specifications such as TO-15 Annex A.

Software & Data Management

Control is managed via embedded firmware with local touchscreen operation; optional PC-based software (GHD-Control Suite v3.x) provides advanced sequence scheduling, remote diagnostics, and CSV/Excel-compatible export of injection metadata (sample ID, timestamp, canister pressure, transfer volume, system status). All software modules support user role management (administrator/operator), electronic signatures per FDA 21 CFR Part 11 (when deployed with validated Windows OS environment), and automatic backup of method and log files to network drives or USB storage. Audit trails capture all parameter modifications, login/logout events, and error recovery actions—retained for ≥18 months per laboratory data retention policy.

Applications

  • Ambient and source emission monitoring per EPA and MEE regulatory frameworks
  • Indoor air quality assessment in commercial buildings, schools, and healthcare facilities
  • Method validation studies requiring high-reproducibility gas-phase sample introduction
  • Long-term trend analysis using archived canister samples from air monitoring networks
  • Calibration gas delivery for GC detector linearity verification and response factor determination
  • Multi-lab intercomparison programs where standardized sample handling across platforms is critical

FAQ

Does the GHD-5001 support internal standard addition during sample transfer?
No—internal standard spiking must be performed upstream at the canister or bag level prior to autosampler loading.
Can it handle humid or particulate-laden air samples?
Yes, provided samples are filtered inline (e.g., 0.2-µm PTFE membrane) before entering the autosampler; condensation must be removed via Nafion dryer or chilled trap.
Is firmware upgradable in the field?
Yes—updates are delivered via USB stick with cryptographic signature verification to ensure integrity and traceability.
What maintenance intervals are recommended for valves and seals?
Valve manifolds require inspection every 6 months or after 5,000 injections; silanized tubing is rated for ≥2 years under continuous VOC service.
Does the system provide pressure leak detection?
Yes—automated pressure hold test (15-minute stabilization + drift threshold ≤0.5 psi/min) is executed before each sequence.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0