Empowering Scientific Discovery

HUANKONG APK2600 Multi-Channel Gas Bag Autosampler

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HUANKONG
Origin Shandong, China
Manufacturer Type Direct Manufacturer
Product Category Domestic
Model APK2600
Instrument Type Gas Chromatography Autosampler
Max Sample Capacity 15 gas bags
Minimum Injection Volume 0.1 µL
Quantitative Loop Volume Software-Controlled
Positioning Accuracy <0.3 mm
Actuation Method Pump-Driven Aspiration
Needle Wash Mode Internal & External Wall Rinse
Repeat Injection Capability Unlimited cycles per sample

Overview

The HUANKONG APK2600 Multi-Channel Gas Bag Autosampler is an engineered solution for automated, high-integrity introduction of gaseous samples from flexible sampling media—including Tedlar® bags, stainless-steel canisters, and direct gas lines—into gas chromatography (GC) systems. Designed specifically for trace-level volatile organic compound (VOC) analysis, environmental monitoring, industrial hygiene, and emissions testing, the APK2600 operates on a pump-driven aspiration principle to ensure precise volumetric transfer without pressure-dependent variability. Unlike syringe-based or pressure-balance autosamplers, this system eliminates reliance on carrier gas backpressure or bag elasticity, thereby delivering consistent injection volumes across heterogeneous bag materials and aging conditions. Its architecture supports seamless integration with both standalone GC instruments and comprehensive online monitoring platforms requiring unattended multi-sample sequencing.

Key Features

  • 15 independent sampling channels with individual valve control, enabling parallel preparation and sequential injection without cross-contamination.
  • Pump-driven aspiration mechanism ensures stable, repeatable draw-and-inject cycles regardless of bag fill pressure (0.5–30 psi typical range) or ambient temperature fluctuations.
  • Positioning accuracy of <0.3 mm guarantees reproducible needle insertion depth into septum-sealed GC inlets, minimizing carryover and septum wear.
  • Integrated dual-stage needle wash station performs simultaneous internal lumen flush and external surface rinse using programmable solvent sequences (e.g., methanol, acetone, nitrogen purge), validated per ASTM D6420-22 protocols for VOC analysis.
  • Software-controlled quantitative loop volume selection allows dynamic adjustment between 0.1 µL and 1.0 mL increments, supporting both ultra-trace detection and higher-concentration calibration standards.
  • Unlimited repeat injection capability per sample position supports method validation requirements including precision testing (n ≥ 7 injections), retention time stability assessment, and system suitability checks.

Sample Compatibility & Compliance

The APK2600 accommodates standard 1–10 L Tedlar®, FlexFoil®, and aluminum-laminated gas sampling bags compliant with EPA Method TO-14A and TO-15 specifications. It also interfaces directly with 6- and 11-mL SUMMA®-coated canisters via optional adapter modules. All wetted surfaces—needle, loop, valves, and tubing—are constructed from electropolished 316 stainless steel and PFA-lined components to prevent adsorption or catalytic degradation of reactive species (e.g., formaldehyde, hydrogen sulfide, chlorine dioxide). The system meets mechanical design requirements outlined in ISO/IEC 17025:2017 for accredited testing laboratories and supports audit-ready operation under GLP and GMP environments when paired with 21 CFR Part 11-compliant software extensions.

Software & Data Management

Controlled via Windows-based HUANKONG GC-Link™ software, the APK2600 provides full method scripting, real-time status monitoring, and event-logged diagnostics. Users define injection sequences, dwell times, wash cycles, and loop fill parameters through intuitive graphical workflow editors. Audit trails record all user actions, parameter changes, and hardware events with timestamped, non-editable entries. Raw sequence files are exportable in .csv and .xml formats compatible with LIMS platforms (e.g., LabWare, Thermo Fisher SampleManager). Optional OPC UA server integration enables bidirectional communication with distributed control systems in continuous emission monitoring (CEMS) applications.

Applications

  • Regulatory air quality monitoring per EPA Methods TO-14A, TO-15, and ASTM D5504 for sulfur compounds.
  • Workplace exposure assessment under OSHA ID-255 and NIOSH 1501 protocols.
  • Odorant profiling and leak detection in petrochemical, wastewater, and landfill gas facilities.
  • Method development and validation for thermal desorption–gas chromatography (TD-GC) coupling where bag-derived standards require high-fidelity transfer.
  • Automated calibration verification using multi-level gas standards across extended runtime (72+ hours unattended).

FAQ

Is the APK2600 compatible with third-party GC systems?
Yes — it supports analog trigger input/output, RS-232/485 serial commands, and Ethernet-based protocol emulation for Agilent, Thermo Fisher, Shimadzu, and PerkinElmer GC platforms.
Can the system handle humid or particulate-laden gas streams?
With optional inline moisture traps (Nafion® or chilled condenser modules) and 0.5 µm particulate filters, the APK2600 maintains performance in ambient air or stack gas applications per ISO 16000-6 guidelines.
Does the software support IQ/OQ/PQ documentation packages?
HUANKONG provides vendor-qualified installation qualification (IQ) and operational qualification (OQ) templates; performance qualification (PQ) protocols are customizable per client SOPs and regulatory jurisdiction.
What maintenance intervals are recommended for long-term reliability?
Valve actuation life exceeds 500,000 cycles; needle replacement is advised every 10,000 injections; pump diaphragms require replacement annually under continuous operation.

InstrumentHive