Empowering Scientific Discovery

GreenPrima PM8202 CL Residual Chlorine and Chlorine Dioxide Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand GreenPrima
Origin United Kingdom
Manufacturer Type Original Equipment Manufacturer (OEM)
Product Category Imported Instrument
Model PM8202 CL
Instrument Type Online Analyzer
Measurement Principle Amperometric Detection at Fixed Potential (Constant Voltage Method)
Measured Parameters Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone
Range 0.00–20.00 ppm / 0.00–200.00 ppb
Accuracy ±2% of Full Scale (F.S.)
Resolution 0.001 ppm / 0.01 ppm
Temperature Compensation –10 to +130 °C (NTC10K or PT1000 sensor compatible)
Operating Temperature –10 to +70.0 °C
Storage Temperature –20 to +70.0 °C
Display Backlit Graphic LCD (Chinese/English Switchable)
Data Storage 600,000 records
Power Supply 90–260 VAC, 50/60 Hz or 24 VDC (optional)
Output Dual isolated 4–20 mA (0.1% F.S., max. loop resistance 500 Ω), RS485 Modbus RTU
Relay Outputs 2 programmable SPDT relays (5 A / 250 VAC / 30 VDC)
Cleaning Control Adjustable interval (0.1–1000 h) and duration (1–1000 s)
Alarm Logic Dual independent Hi/Lo setpoints with user-defined hysteresis
Enclosure Rating IP65
Dimensions (W×H×D) 144 × 144 × 108 mm
Panel Cutout 138 × 138 mm
Weight 0.87 kg
Mounting Options Wall-mounted, Pipe-mounted, Panel-mounted

Overview

The GreenPrima PM8202 CL is an online amperometric residual disinfectant analyzer engineered for continuous, reagent-free monitoring of free chlorine, total chlorine, chlorine dioxide, and ozone in aqueous systems. It operates on the constant-voltage amperometric principle—applying a fixed polarization potential across a dual-electrode sensing system (Pt/Pt or Au/Au configuration) to selectively oxidize target disinfectants at the working electrode surface. The resulting diffusion-controlled current is linearly proportional to analyte concentration, enabling stable, drift-resistant measurements without chemical reagents, membranes, or electrolyte replenishment. Designed for integration into municipal drinking water distribution networks, hospital wastewater treatment streams, secondary water supply systems, and industrial process water loops, the PM8202 CL delivers high reproducibility under variable flow and temperature conditions through its integrated BAF615 constant-flow cell and real-time NTC10K/PT1000 temperature compensation.

Key Features

  • True reagentless operation: No colorimetric reagents, membrane replacements, or internal electrolyte refills required—reducing maintenance intervals and operational cost of ownership.
  • Dual-electrode amperometric sensor architecture (Bsens650 Pt/Pt or Bsens660 Au/Au) provides inherent interference rejection against common oxidants and reducing agents, improving measurement robustness in complex matrices.
  • Integrated BAF615 constant-flow cell ensures laminar, pulse-free sample delivery at precisely regulated velocity—critical for stabilizing diffusion layer thickness and minimizing flow-dependent signal variance.
  • Triple-analyte capability: Single instrument platform supports sequential or simultaneous calibration and measurement of free chlorine, chlorine dioxide, and ozone—validated per ASTM D6503, ISO 7393-2, and EN 15354 protocols.
  • Configurable dual 4–20 mA analog outputs with independent scaling; each output assignable to measured parameter, temperature, or diagnostic status—compliant with IEC 61000-6-2/4 EMC standards.
  • Modbus RTU over RS485 enables seamless integration into SCADA, DCS, and PLC-based supervisory systems; firmware supports standard function codes 03 (read holding registers) and 06 (preset single register).
  • Full data integrity architecture: Local storage of 600,000 timestamped records (parameter value, temperature, sensor status, calibration event) with automatic overwrite policy; no external memory card required.
  • Multi-mode mounting: Field-configurable for wall, pipe, or panel installation; IP65-rated enclosure withstands humid, chemically aggressive environments typical of pump stations and utility vaults.

Sample Compatibility & Compliance

The PM8202 CL is validated for use in potable water, low-conductivity process water (<500 µS/cm), and mildly contaminated effluents (COD < 50 mg/L). It meets key regulatory and quality framework requirements including EPA Method 334.0 (amperometric chlorine), ISO 7393-2 (electrochemical chlorine determination), and EN 15354 (chlorine dioxide in drinking water). Its design supports GLP-compliant data handling: all calibrations, alarms, and configuration changes are logged with user ID (via password-protected access), timestamp, and pre-/post-event values. Optional audit trail export via Modbus enables alignment with FDA 21 CFR Part 11 electronic record requirements when deployed in pharmaceutical or healthcare facility water systems.

Software & Data Management

The embedded firmware implements deterministic real-time control with 1-second measurement cycle time and configurable averaging (1–128 samples). All configuration parameters—including calibration coefficients, alarm thresholds, relay logic, and cleaning schedules—are stored in non-volatile EEPROM with write-cycle protection. Data export is supported via ASCII-formatted serial dump (RS485) or periodic analog snapshot; no proprietary software is required for basic commissioning. For advanced diagnostics, optional GreenPrima Analytics Suite (Windows-based) provides trend visualization, calibration history review, sensor health assessment (including polarization voltage stability and zero-current drift metrics), and CSV report generation compliant with ISO/IEC 17025 documentation standards.

Applications

  • Municipal drinking water distribution: Real-time verification of chlorine residual at entry points, booster stations, and zone boundaries to ensure regulatory compliance (e.g., WHO Guidelines, EU Drinking Water Directive 98/83/EC).
  • Hospital central sterile supply departments (CSSD): Continuous monitoring of chlorine dioxide concentration in water used for instrument reprocessing to prevent biofilm formation and meet HTM 01-05 specifications.
  • Food & beverage production lines: In-line verification of sanitizing rinse water (e.g., post-CIP chlorine concentration) to satisfy SQF Code Edition 9 and BRCGS Global Standard for Food Safety.
  • Pharmaceutical purified water (PW) and water-for-injection (WFI) loops: Monitoring of ozone residuals during periodic sanitization cycles per USP and Annex 1 (EMA) requirements.
  • Industrial cooling tower systems: Detection of free chlorine decay kinetics to optimize biocide dosing frequency and minimize corrosion risk.

FAQ

What electrochemical principle does the PM8202 CL employ?
It uses constant-potential amperometry—applying a fixed bias voltage between working and counter electrodes to drive selective oxidation of residual disinfectants, generating a diffusion-limited current proportional to concentration.
Can the same sensor measure chlorine, chlorine dioxide, and ozone simultaneously?
No—measurements are performed sequentially using dedicated calibration curves and optimized polarization potentials; however, a single instrument can be configured for any one of the three analytes per operational cycle.
Is temperature compensation automatic or manual?
Both modes are supported: automatic compensation via integrated NTC10K or PT1000 probe, or manual offset input within ±10 °C range.
Does the analyzer support remote calibration verification?
Yes—through Modbus register interrogation of sensor zero-current baseline, polarization voltage stability, and response time metrics; full calibration requires physical standard addition.
What is the maximum allowable sample turbidity or suspended solids content?
For optimal performance, turbidity should remain below 5 NTU and suspended solids below 10 mg/L; higher levels necessitate upstream filtration or flow-cell cleaning cycle optimization.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0