- All
- Favorite
- Popular
- Most rated
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LB-6000 |
| Instrument Type | Palm-Sized Centrifuge |
| Speed Range | 0–6,000 rpm |
| Max RCF | 1,600 × g |
| Max Capacity | 8 × 2.0 mL tubes |
| Rotor Configuration | Fixed-angle rotor (dual-standard: 1.5/2.0/0.5/0.2 mL tubes and 4 × 8-strip PCR tubes) |
| Dimensions | 150 × 120 × 180 mm (W × D × H) |
| Safety Features | Lid interlock, automatic rotor recognition, over-speed protection, imbalance detection |
| Housing Material | Reinforced polymer composite |
| Compliance | CE-marked per IEC 61010-1 for laboratory equipment safety |
| Brand | Langbo |
|---|---|
| Model | DMK-1 |
| Temperature Range | −10 °C to 100 °C |
| Stability @ 100 °C | ≤ ±0.5 °C |
| Uniformity @ 40 °C | ≤ ±0.3 °C |
| Max. Module ΔT @ 40 °C | 0.3 °C |
| Display Resolution | 0.1 °C |
| Timer Range | 0–99 h 59 min |
| Heating Time (20 °C → 100 °C) | ≤15 min |
| Cooling Time (20 °C → −5 °C, 30 °C ambient) | ≤20 min |
| Cooling Time (20 °C → −10 °C, 25 °C ambient) | ≤30 min |
| Max. Power | 200 W |
| Dimensions (W×D×H) | 300 × 220 × 170 mm |
| Net Weight | 5 kg |
| Compliance | CE-marked design principles |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | FS-1 |
| Price | USD 280 (FOB Jiangsu) |
| Speed Range | 0–20,000 rpm |
| Maximum Sample Volume | 150 mL |
| Minimum Sample Volume | 5 mL |
| Shaft Material | Stainless Steel 316L |
| Drive Mechanism | Brushless DC Motor |
| Speed Control | Analog Knob with Digital RPM Display |
| Footprint | 180 × 140 × 220 mm |
| Weight | 3.2 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Safety Certification | CE, RoHS compliant |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | LB-211B |
| Instrument Type | Air-Bath Constant-Temperature Orbital Shaker |
| Timer Range | 1–999 min |
| Oscillation Frequency | 50–250 rpm |
| Oscillation Amplitude | 30 mm |
| Temperature Range | 4–60 °C |
| Platform Quantity | 1 |
| Capacity | 250 mL × 40 or 2000 mL × 6 (standard configuration) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | BLQX-220 |
| Price | USD 19,200 (FOB Jiangsu) |
| Construction | AISI 304 Stainless Steel Cabinet & Chamber |
| Door | Single Front-Loading Pull-Out Door |
| Control System | PLC-Based Microprocessor Controller with LCD Interface |
| Wash Programs | Pre-Programmed & User-Defined Cycles |
| Water Inlets | Three Independent Connections (Cold Water, Hot Water, Deionized Water) |
| Drying System | Heated Air Circulation with Dual-Layer Rack Support |
| Filtration | Integrated HEPA-Filtered Recirculated Air System |
| Safety Protections | Overtemperature Cut-off, Phase Failure Detection, Door Interlock, Leakage Current Protection |
| Optional Module | Integrated Pure Water Generation System (UPW, ≥18.2 MΩ·cm resistivity) |
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Region | Domestic (China) |
| Model | LBJK-3A |
| Price | USD 40,200 (FOB Jiangsu) |
| Temperature Range | 0–800 °C (Resolution: 0.1 °C |
| Control Accuracy | ±0.5 °C) |
| Heating Program | 0–250 °C @ 8 °C/min (30 min), 250–800 °C @ 3 °C/min (160 min) |
| Y-value Repeatability | ±2 mm (Y > 20 mm), ±1 mm (Y ≤ 20 mm) |
| X-value Repeatability | ±3 mm |
| Thermocouple | Armored K-type, Class 0.5 |
| Load Cell Accuracy | 0.02 % FS |
| Volume Sensor Accuracy | 0.05 % FS |
| Probe Displacement Sensor Accuracy | 0.01 % FS |
| Exhaust Motor Power | 60 W |
| Push Rod Max Force | 800 N |
| Dimensions | 600 × 450 × 1150 mm |
| Power Supply | 220 V, 50 Hz, 8 kW (dual furnace) |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | GFGDJS-1500 |
| Internal Dimensions (W×D×H) | 1000 × 1000 × 1500 mm |
| Temperature Range | −40 °C to +100 °C |
| Temperature Cycling Range | −40 °C to +100 °C |
| Humidity Range | 30–98% RH (at 40–90 °C) |
| Humidity Cycling Range | 75–95% RH (at 25–85 °C) |
| Temperature Uniformity | ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Deviation | +2 / −3% RH |
| Heating/Cooling Rate | 1.0–2.0 °C/min (linearly adjustable) |
| Timer Range | 0–9999 h |
| Power Supply | AC 380 V, 50 Hz |
| Total Power Consumption | 32 kW |
| Refrigerant | R23 / R404A |
| Control Resolution | 0.1 °C |
| Display | 5.7″ LED touchscreen interface |
| Compliance | GB/T 19394–2003, GB/T 9535–1998, GB/T 6492–1986, IEC 61215:2005, IEC 61646, IEC 61345:1998 |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | SW-CJ-1D |
| Price | USD 680 (FOB Jiangsu) |
| Cleanliness Class | ISO Class 5 (equivalent to Fed. Std. 209E Class 100 @ ≥0.5 µm) |
| Microbial Count | ≤0.5 CFU/plate·hour (Φ90 mm settle plate) |
| Average Air Velocity | 0.25–0.45 m/s (dual-speed control) |
| Noise Level | ≤62 dB(A) |
| Vibration Peak-to-Peak | ≤1.0 µm (X/Y/Z axes) |
| Illuminance | ≥300 lx |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 130 W |
| Net Weight | <85 kg |
| HEPA Filter Size & Qty | 695 × 455 × 50 mm × 1 |
| Fluorescent Lamp / UV Lamp | 15 W × 1 / 15 W × 1 |
| Work Area Dimensions | 700 × 500 × 500 mm |
| Overall Dimensions | 850 × 580 × 1600 mm |
| User Capacity | Single operator, front-facing access |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Voltage | 220–230 V AC, 50–60 Hz |
| Temperature Range | 5–50 °C |
| Temperature Uniformity | ≤ ±1 °C |
| Temperature Stability (Fluctuation) | ≤ ±1 °C |
| Compressor Power | 230 W |
| Heating Power | 300 W |
| Control System | PID-based Digital Temperature Controller |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | LHH-150GSP, LHH-250GSP |
| Internal Dimensions (L×W×H) | 600×405×620 mm |
| Temperature Range | 0–65°C (dark), 10–65°C (light) |
| Humidity Range | 40–98% RH |
| Illumination | 0–6000 lx (adjustable) |
| Temperature Control Accuracy | ±0.1°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Uniformity | ±3% RH |
| Temperature Sensor | Imported Swiss PT100 Platinum Resistance Thermometer |
| Humidity Sensing | Direct-reading PT100-based RH sensor |
| Power Supply | 380 V, 50 Hz, 3-phase 5-wire |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | LB-2102 |
| Timer Range | 0–999 h |
| Oscillation Frequency | 40–280 rpm |
| Orbit Diameter | 50 mm |
| Temperature Range | 4–60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Stability | ±0.5 °C |
| Tray Dimensions | 750 × 500 mm |
| Number of Trays | 2 |
| Max Capacity | 70 × 250 mL or 50 × 500 mL or 24 × 1000 mL |
| Drive Type | Brushless DC Motor |
| Control System | Microprocessor-based with Programmable Multi-Stage Profile (up to 10 segments) |
| Safety Features | Independent Over-Temperature Cut-off, Door Interlock Switch, Motor Overheat Protection, Power-Fail Recovery, Soft-Start Acceleration |
| Optional | Humidity Control Module, USB Data Logging Interface, Stainless Steel Mirror-Finish Interior, Tempered Glass Viewing Window, Inert Gas Inlet Port |
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | LBJK-3 |
| Price | USD 27,500 (FOB Jiangsu) |
| Temperature Control Range | 0–800 °C |
| Control Accuracy | ±3 °C |
| Power Supply | 220 V, 50 Hz, 8 kW |
| Y-value Accuracy | <2 mm (Y > 20 mm), <1 mm (Y < 20 mm) |
| X-value Accuracy | ΔX < 3 mm |
| Thermocouple Type | K-type |
| Accuracy Class | 0.5 |
| Load Cell Range | 0–10 kg |
| Displacement Sensor Range | 0–100 mm, Class 0.01 |
| Stepper Motor Holding Torque | 10 N·cm |
| Probe Design | Rotating, Auto-Alignment |
| Data Acquisition | PC-based, Real-time Curve Rendering (X/Y Volume Curves) |
| Compliance | Fully Conforms to GB/T 479–2016 |
| Safety | Integrated Power-Failure Protection |
| Software | Custom GUI with ASTM/ISO-aligned reporting templates, Manual & Auto Measurement Modes |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LH-010, LH-225 |
| Temperature Range | RT+10°C to 200°C |
| Temperature Uniformity | ≤ ±1.5°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Heating Rate | ~50 min (20°C → 200°C) |
| Air Exchange Rate | 10–300 cycles/hour (adjustable) |
| Sample Rack Rotation Speed | 10–12 rpm |
| Compliance | JB/T 7444–1994, IEC 60540 |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | HS-100 / DHS-100 |
| Internal Volume | 100 L |
| Interior Dimensions (W×D×H) | 400 × 500 × 500 mm |
| Temperature Range | HS-type: RT+10°C to 100°C |
| DHS-type | 0°C to 100°C |
| Humidity Range | HS-type: 85–98% RH |
| DHS-type | 45–98% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Humidification Method | Shallow-water tray evaporation (surface evaporation) |
| Construction | Stainless steel inner chamber, polyurethane foam insulation |
| Cooling System | Finned stainless steel heat exchanger with multi-stage evaporator |
| Refrigeration Options | Single-stage or cascade (dual-stage) refrigeration (air-cooled or water-cooled) |
| Compressor | Imported hermetic scroll compressor |
| Controller | Fuji Electric PID temperature & humidity controller (Japan) |
| Sensors | Imported high-accuracy capacitive RH sensor and Pt100 temperature probe |
| Safety Protections | Leakage current protection, low-water-level cutoff, overtemperature cutoff, fast-acting fuse, compressor high-pressure protection |
| Test Conditions | All specifications measured at ambient temperature (QT) = 25°C, empty chamber, steady-state operation |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | MS-015 / MS-025 |
| Temperature Range | 20–80 °C |
| Humidity Range | 45–98 %RH |
| Humidity Deviation | ≤ +2 to –3 %RH |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ≤ ±0.5 °C |
| Controller | Fuji Electric Programmable Temperature & Humidity Controller |
| Interior Material | Stainless Steel (AISI 304) |
| Exterior Material | Powder-Coated Carbon Steel |
| Humidification Method | Surface Evaporation |
| Refrigeration System | Imported Compressor-Based Cooling |
| Safety Protections | Over-Temperature, Over-Pressure, and Low-Water-Level Interlocks |
| Compliance | GB/T 2423.16–1999 (IEC 60068-2-10), GJB 150.10A–2009 |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HH-4 (Single-Row) |
| Temperature Range | Ambient to 100°C |
| Heating Power | 1000 W |
| Working Chamber Dimensions | 610 × 160 × 130 mm |
| Display | Digital LED Controller |
| Construction | Stainless Steel Inner Tank & Powder-Coated Steel Exterior |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LB-90 |
| Instrument Type | High-Temperature Forced-Air Drying Oven |
| Temperature Range | RT+10°C to 250°C |
| Temperature Uniformity | ±1°C |
| External Dimensions | 450 × 400 × 300 mm (W×D×H) |
| Internal Chamber Dimensions | 250 × 320 × 80 mm (W×D×H) |
| Power Supply | 220 V ±10%, 50 Hz |
| Rated Power | 500 W |
| Net Weight | ~20 kg |
| Air Exchange Rate | 15 cycles/hour |
| Chamber Material | 304 Stainless Steel |
| Heating Element | Embedded Stainless Steel Sheathed Tubular Heater |
| Door Seal | High-Temperature Silicone Gasket with Mechanical Compression Lock |
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-1030 |
| Price | USD 2,750 (FOB Jiangsu) |
| Temperature Range | −10 to 100 °C |
| Temperature Stability | ±0.05 °C |
| Chamber Dimensions | 400 × 325 × 230 mm (L×W×H) |
| Capacity | 30 L |
| Circulation Pump Flow Rate | 15 L/min |
| Opening Dimensions | 310 × 280 mm |
| Construction | Full Stainless Steel Interior and Work Surface |
| Control System | Digital Microprocessor-Based PID Controller with Dual Internal/External Circulation Modes |
| Safety Protections | Compressor Overheat & Overcurrent Protection |
| Optional Accuracy | ±0.01 °C or ±0.001 °C (with high-stability sensor and advanced PID tuning) |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | GDJS-010 |
| Temperature Range | −20 °C to +150 °C |
| Refrigeration | Hermetic Compressor Cooling |
| Explosion-Proof | Standard (Non-Explosion-Proof) |
| Temperature Uniformity | ±1 °C |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Deviation | ±1 °C |
| Heating Rate | ≤60 min (−20 °C → +150 °C) |
| Cooling Rate | ≤80 min (+150 °C → −20 °C) |
| Interior Dimensions | 450 × 450 × 450 mm |
| Internal Volume | 91.1 L |
| Humidity Range | 30–98 %RH |
| Humidity Control Accuracy | ±2–3 %RH |
| Controller | Fuji PID-based Touchscreen HMI with Programmable Profile Storage |
| Construction | SUS304 Stainless Steel Interior |
| Insulation | Polyurethane Foam (≥100 mm Thickness) |
| Viewing Window | Double-Layer Hollow Glass with Anti-Condensation Heater |
| Safety Protections | Low-Water Cut-off, Over-Temperature Cut-off, Compressor High-Pressure Protection |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | YQX-II |
| Instrument Type | Manual Anaerobic Incubator |
| Oxygen Concentration Range | 0–20% (adjustable) |
| Temperature Control Range | Ambient +5°C to 50°C |
| Temperature Uniformity & Stability | ±1°C |
| Humidity Capability | Compatible with ambient humidity ≤75% RH |
| Gas Supply | Nitrogen (N₂) |
| Chamber Dimensions (W×D×H) | 820 × 550 × 660 mm |
| Internal Volume | Approx. 297 L |
| Deoxygenation Method | Catalytic Oxygen Removal + Vacuum/Flush Protocol |
| Safety Features | Over-Temperature Cut-Off, UV Sterilization Lamp, Locked Gas Valves, Dual-Glove Access |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Models | DC-0515, DC-1006 |
| Temperature Range | −5 °C to 100 °C (DC-0515) |
| Internal Dimensions (W×D×H) | 250×200×200 mm (DC-0515), 300×250×200 mm (DC-1006) |
| Working Volume | 10 L (DC-0515), 15 L (DC-1006) |
| Temperature Uniformity | ≤ ±0.1 °C |
| Temperature Stability | ≤ ±0.5 °C |
| Circulation Flow Rate | ≥ 8 L/min |
| Construction | Stainless Steel Interior Tank, Powder-Coated Steel Exterior |
| Control System | Microprocessor-Based PID Controller with Digital Display |
| Heating Method | Enclosed Immersion Heater |
| Cooling Method | Integrated Refrigeration System with Internal Coiled Heat Exchanger |
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DHG-1600A |
| Price Range | USD 70,000 – 140,000 |
| Channels | 36 (standard), up to 72 or custom-configurable |
| Temperature Range | Ambient to 80 °C |
| Temperature Accuracy | ±0.5 °C |
| Airflow Control Range | 0.01–10 L/min |
| Airflow Accuracy | ±1.0 % FS |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±40 ppm (0–3,000 ppm), ±2 % (3,000–10,000 ppm) |
| O₂ Detection Range | 0–25 % |
| O₂ Detection Accuracy | ±1 % FS |
| Pressure Range | 0–200 kPa |
| Pressure Accuracy | ±1 % FS |
| Reaction Vessel Volume | 3.5 L per chamber |
| Total Chambers | 18 |
| Power Supply | 220 V AC, 50 Hz, 3000 W |
| Dimensions | 3600 × 810 × 1930 mm |
| Weight | 1100 kg |
| Compliance | GB/T 19277.1–2011, GB/T 19277.2–2013, GB/T 22047–2008, ISO 14855-1:2012, ISO 14855-2:2018, ISO 17556:2012, ASTM D5338, EN 13432, GB/T 20197–2016 |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | SHA-C |
| Price | USD 680 (FOB Jiangsu) |
| Temperature Range | Ambient +5°C to 100°C |
| Oscillation Frequency | 0–300 rpm |
| Stroke | 20 mm (Reciprocating) |
| Heating Power | 1800 W |
| Timer | 0–120 min or Continuous Operation |
| Capacity | 12 × 250 mL, 8 × 500 mL, or 4 × 1000 mL Erlenmeyer Flasks |
| Temperature Accuracy | ≤ ±1°C |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | TCLB-6A |
| Instrument Type | Inverting Shaker |
| Temperature Range | Ambient +5°C to 60°C |
| Timer Range | 0–999 h |
| Speed Range | 0–45 rpm (no-load), 30 ±2 rpm (loaded, 2 L bottles) |
| Number of Shaking Plates | 2 |
| Chamber Material | Stainless steel housing with electrostatic powder coating |
| internal fixtures | aluminum alloy |
| Safety Features | Overload protection |
| Compatible Vessels | 2 L glass, PE, PTFE, and ZHE containers |
| Compliance | Designed for GLP-compliant laboratory workflows requiring traceable, repeatable sample inversion under controlled thermal conditions |