Empowering Scientific Discovery

MakeWave MKX-X2G40A 40-Position High-Throughput Microwave Digestion System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand MakeWave
Origin Shandong, China
Manufacturer Type Direct Manufacturer
Country of Origin China
Model MKX-X2G40A
Microwave Source Dual Magnetron
Max Temperature 220 °C (standard), 300 °C (short-term)
Max Pressure 8 MPa (800 bar)
Sample Capacity 40 × 55 mL PFA vessels per run
Cavity Volume ~60 L
Microwave Frequency 2450 MHz
Rated Power Output 1600 W (continuous, non-pulsed)
Safety Leakage <5 mW/cm²
Compliance ISO 9001 certified
Power Supply 220 V AC / 50 Hz
Weight 100 kg
Dimensions (W×H×D) 545 × 662 × 650 mm

Overview

The MakeWave MKX-X2G40A is an industrial-grade, high-throughput microwave digestion system engineered for reproducible, trace-level elemental analysis in regulated and research-intensive laboratories. It operates on the principle of closed-vessel microwave-assisted acid digestion—utilizing controlled electromagnetic energy at 2450 MHz to rapidly elevate temperature and pressure within chemically inert PFA reaction vessels. This enables complete mineralization of complex organic and inorganic matrices under precisely monitored conditions, ensuring quantitative recovery of analytes such as Cr, Cd, Hg, As, and Pb. Designed for compliance-driven workflows, the system supports method validation according to EPA Method 3051A/3052, ISO 11466, ASTM D5762, and USP , making it suitable for environmental monitoring, food safety testing, pharmaceutical QA/QC, and materials characterization where regulatory traceability is mandatory.

Key Features

  • 40-position digestion capacity per batch using standardized 55 mL PFA vessels—enabling high sample throughput without compromising vessel integrity or thermal uniformity
  • Dual-magnetron microwave generation with continuous, non-pulsed 1600 W output ensures stable energy delivery and minimizes hot-spot formation across the cavity
  • Robust 304 stainless steel monolithic cavity with multi-layer PTFE coating resists aggressive reagents (e.g., HNO₃/HF/HClO₄ mixtures) and withstands sustained operation at up to 300 °C and 8 MPa
  • Real-time, vessel-specific monitoring via dual-circumferential infrared temperature sensing and contactless in-situ pressure transducers—each vessel independently tracked throughout the digestion cycle
  • 360° orbital rotation mechanism guarantees homogeneous microwave coupling and eliminates positional bias in heating profiles
  • Integrated LED illumination and high-resolution color video monitoring allow visual verification of sample behavior—including reflux, color change, and gas evolution—without interrupting digestion
  • PLC-based control architecture with industrial-grade touchscreen interface supports programmable ramp-hold-cool protocols, automatic data logging, and audit-ready event tracing

Sample Compatibility & Compliance

The MKX-X2G40A accommodates a broad spectrum of solid and semi-solid samples, including soil, sediment, plant tissue, food composites (dairy, cereals, beverages, tea), polymers, textiles, catalysts, coal, ores, and biological tissues. Its sealed PFA vessel system maintains chemical compatibility with hydrofluoric acid, enabling silicate dissolution for geological and metallurgical applications. All operational parameters—including temperature, pressure, power, and time—are recorded with timestamped metadata, supporting GLP/GMP documentation requirements. The system meets ISO 9001 quality management standards and exceeds national safety limits for microwave leakage (<5 mW/cm²). Optional configuration supports 2000 W power upgrade and 110 mL vessel expansion for high-mass or low-surface-area samples.

Software & Data Management

The embedded control software provides real-time graphical display of temperature, pressure, and microwave power curves for all vessels simultaneously. Data are stored internally in CSV-compatible format and exportable via USB interface for integration into LIMS or statistical analysis platforms (e.g., JMP, Minitab). Multi-user password protection, electronic signature support, and configurable audit trails align with FDA 21 CFR Part 11 requirements for electronic records. Up to 100 user-defined digestion methods can be saved, edited, duplicated, or deleted directly from the touchscreen interface. Firmware updates are performed offline via secure USB media to maintain system integrity during routine operation.

Applications

This system serves as a primary sample preparation platform for ICP-OES, ICP-MS, AAS, and HG-AFS instrumentation across multiple sectors: environmental labs conducting heavy metal profiling in water, sludge, and airborne particulates; food testing facilities verifying compliance with EU Commission Regulation (EC) No 1881/2006; pharmaceutical manufacturers validating elemental impurities per ICH Q3D; and industrial R&D centers analyzing catalyst poisons, polymer additives, or battery electrode materials. Its reliability under repeated high-pressure cycles makes it especially suited for accredited laboratories requiring consistent inter-batch precision and long-term instrument stability.

FAQ

What safety certifications does the MKX-X2G40A hold?

The system complies with ISO 9001 quality management standards and meets or exceeds national electromagnetic safety regulations (microwave leakage <5 mW/cm²). While not CE-marked for EU placement, its mechanical and electrical design follows IEC 61000-4 immunity guidelines and incorporates redundant hardware interlocks.

Can the system be integrated with laboratory information management systems (LIMS)?

Yes—raw digestion data (time-stamped T/P/power logs) are exportable in CSV format. Custom API integration is available upon request for enterprise-level LIMS connectivity.

Is HF acid digestion supported?

Yes—PFA vessels and cavity coating are fully compatible with hydrofluoric acid up to 49% concentration at temperatures ≤220 °C. Vessel caps include reinforced pressure-relief mechanisms rated for 3 MPa burst tolerance.

What maintenance is required for long-term reliability?

Routine cleaning of cavity walls and waveguide cover, annual calibration of IR sensors and pressure transducers, and periodic inspection of door gasket integrity constitute the recommended preventive maintenance schedule. No consumable magnetron replacement is needed within the first 5,000 operating hours.

Does the system support remote monitoring or network connectivity?

Standard configuration includes local USB data export only. Ethernet or Wi-Fi modules are available as optional add-ons for remote diagnostics and scheduled firmware updates—subject to site-specific cybersecurity policies.