- All
- Favorite
- Popular
- Most rated
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKX-WD6A |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Category | Reaction Vessel |
| Usable Volume | Large-scale (35 L cavity |
| Construction Material | AISI 304 Stainless Steel |
| Operating Pressure | High-pressure capable (vacuum-compatible) |
| Capacity | 35 L total cavity volume |
| Microwave Frequency | 2450 MHz |
| Max. Temperature | 1700 °C |
| Microwave Power Output | 6–30 kW (continuous, non-pulsed, infinitely variable) |
| Power Density | ≥170 W/L |
| Microwave Leakage | <5 mW/cm² (per GB 10436 & IEC 62233) |
| Compliance | ISO 9001 certified |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKW-XG-2 |
| Pricing | Available Upon Request |
| Input Power | 3-phase, 380 V / 50 Hz, ~10 kVA |
| Microwave Output Power | 1.6 kW (continuously adjustable) |
| Max Operating Temperature | 800 °C (process-controlled), 1200 °C (quartz vessel rating) |
| Dimensions (L×W×H) | 2.5 × 1.5 × 1.8 m |
| Feed System | Dual-stage 304 stainless steel screw feeder with jacketed water cooling on second stage |
| Fluidization Gas Inlet | Preheated via electrically heated quartz tubing |
| Reaction Vessel | Quartz glass, fitted with high-temp porous gas distributor plate |
| Exhaust Line | 304 stainless steel, externally heated & insulated |
| Temperature Sensing | 0–1200 °C armored thermocouple, inserted directly into fluidized bed zone |
| Control System | PLC-based with HMI touchscreen interface, closed-loop temperature & power regulation, real-time data logging and export (CSV) |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MHX-16B |
| Frequency | 2450 MHz |
| Time Control Range | 0–99 h |
| Sample Capacity | 1 vessel |
| Temperature Range | 0–900 °C |
| Temperature Control Accuracy | ±1 °C |
| Maximum Power Output | 16 kW (pyrolysis mode), 5 kW (thermal decomposition mode) |
| Chamber Volume | 66 L |
| Chamber Material | Fused quartz |
| Atmosphere Options | Vacuum or oxidizing (air-assisted) |
| Control System | PLC-based industrial automation with real-time monitoring of temperature, pressure, microwave power, and process sequencing |
| Exhaust Compliance | Meets GB 18484–2001 “Pollution Control Standard for Hazardous Waste Incineration” |
| Microwave Leakage | <5 mW/cm² (per GB 10436–2008) |
| Key | Brand: HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | MSX-G2A |
| Microwave Power | 0–1600 W (continuously adjustable, 2450 MHz) |
| Cavity Volume | 33 L |
| Cavity Material | Industrial-grade 304 stainless steel, fully welded, interior coated with multi-layer PTFE |
| Temperature Range | 0–300 °C (steam/microwave-controlled), optional thermocouple up to 1200 °C |
| UV System | Dual-sided UVC irradiation (254 nm) |
| Steam System | Sealed, recirculating high-temperature steam generator with pressure regulation |
| Air Management | Independent ducted airflow with motorized gate valves for humidification, steaming, drying, and dehumidification modes |
| Control System | PLC-based intelligent controller with 7-inch color touchscreen, multi-stage programmable protocols, real-time temperature/time curve display, data export (USB) |
| Safety Compliance | Interlocked door switch, surface temperature <50 °C, microwave leakage <5 mW/cm² (GB 4706.21–2008), explosion-proof & corrosion-resistant design |
| Dimensions (W×D×H) | 520 × 550 × 618 mm |
| Configuration Options | MSX-G2A1 (Sterilization-Optimized), MSX-G2A2 (Drying-Optimized) |
| Sample Capacity | 1–4 layer stackable trays (metal or PTFE-coated polymer) |
| Regulatory Context | Designed for GLP-compliant sample prep environments |
| Brand | MakeWave (makewave) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | MHS-R Series |
| Pricing | Upon Request |
| Brand | Makewave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | MKX-E1B |
| Microwave Power | 800 W (continuous, non-pulsed) |
| Microwave Frequency | 2450 MHz |
| Temperature Control Range | 0–300 °C |
| Temperature Accuracy | ±1 °C |
| Cavity Material | 304 Stainless Steel with Multi-Layer PTFE Coating |
| Cavity Volume | ~20 L |
| Maximum Vessel Capacity | 2000 mL |
| Microwave Leakage | <5 mW/cm² |
| Power Supply | 220 V AC / 50 Hz |
| Total Power Consumption | 2000 W |
| Dimensions (W×H×D) | 350 × 1350 × 360 mm |
| Weight | 65 kg |
| Certification | ISO 9001 Certified |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXN-W40S |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | 0–300°C |
| Temperature Control Accuracy | ±0.1°C |
| Maximum Sample Volume Capacity | 40 L |
| Microwave Power | 0–800 W at 2450 MHz |
| Electric Heating Power | 1600 W |
| Cavity Volume | 40 L |
| Construction | Stainless Steel Monolithic Welded Body with PTFE Anti-Corrosion Coating |
| Evaporation Vessels | One 2000 mL Ceramic Tray (microwave mode) or Two 2000 mL Standard Glass Beakers (electric heating mode) |
| Acid Removal & Ashing Capacity | Three 100 mL Ceramic Crucibles |
| Temperature Monitoring | Dual-mode — Non-contact Infrared + Thermocouple |
| Exhaust System | Corrosion-Resistant Centrifugal Fan (≤60 dB) |
| Control System | PLC-based Intelligent Touchscreen Interface with LED Internal Illumination and Transparent Observation Window |
| Dimensions (W×D×H) | 760 × 550 × 610 mm |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MKX-M1B |
| Instrument Type | Crucible-Type Muffle Furnace |
| Maximum Temperature | 1200 °C |
| Temperature Control Accuracy | ±3 °C |
| Rated Microwave Power | 800 W (2450 MHz, continuous non-pulsed output) |
| Heating Rate to Max Temp | ≤30 min |
| Internal Cavity Dimensions | 401 mm (W) × 590 mm (H) × 436 mm (D) |
| Effective Heating Volume | ~1.2 L |
| Power Supply | 220 VAC / 50 Hz |
| Total Power Consumption | 1300 W |
| Net Weight | 50 kg |
| Safety Compliance | Microwave Leakage < 5 mW/cm² (per GB 10436–2008, exceeding national limits) |
| Quality Certification | ISO 9001 certified |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HXG-T225 |
| Instrument Type | High-Temperature Microwave Drying Oven |
| Temperature Range | 0–1200 °C (thermocouple) / 0–500 °C (infrared pyrometer) |
| Temperature Uniformity | ±1 °C |
| External Dimensions | 1500 × 750 × 1640 mm |
| Internal Volume | 225 L |
| Chamber Material | AISI 304 Stainless Steel |
| Heating Method | 2450 MHz Microwave + Auxiliary Convection |
| Microwave Power Output | 0–4800 W (infinitely adjustable) |
| Electrical Input Power | 1000 W |
| Microwave Leakage | <5 mW/cm² (GB 10436-2008 compliant) |
| Airflow System | Adjustable axial-flow forced convection |
| Control System | PLC-based with color touchscreen interface |
| Tray Configuration | 1–4 removable perforated stainless steel shelves |
| Safety Features | Interlocked door switch, overtemperature cutoff, pressure-relief venting, explosion-resistant chamber design, EMI-shielded RF cavity |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXO-T50 |
| Power Supply | 220 V ±10 V, 50 Hz ±1 Hz |
| Total Power | 3000 W |
| Temperature Range | 0–1200 °C |
| Control System | PLC-based touchscreen interface with dual-zone 20-segment programmable ramp/soak profiles |
| Heating Tube Dimensions | Ø50 mm × 900 mm |
| Sample Holder | Ceramic boat |
| Temperature Sensing | Type K thermocouples, accuracy ±1 °C |
| Oxidation Configuration | Multi-gas inlet with independent mass flow control (O₂, air, CO₂/O₂ mix), dual-stage condensation for H₂O(³H) capture, tandem alkaline absorption traps for CO₂(¹⁴C) recovery |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKG-H1C1B |
| Reactor Type | Benchtop Continuous-Flow Microwave Reactor |
| Vessel Capacity | 20 L |
| Construction Material | 316 Stainless Steel |
| Operating Pressure Range | 0–0.5 MPa (optional up to 2 MPa) |
| Vacuum Capability | Up to 2 MPa (gauge, negative pressure) |
| Microwave Power Output | 0–800 W (continuous, non-pulsed, linearly adjustable) |
| Frequency | 2450 ± 50 MHz |
| Reaction Temperature Range | 0–100 °C (optional up to 200 °C) |
| Flow Rate Range | 0–1000 mL/min |
| Tubing Diameter | Φ6 mm (Φ1–Φ10 mm optional) |
| Control System | PLC-based with 7-inch color touchscreen HMI |
| Safety Compliance | Microwave leakage < 5 mW/cm² (per GB 10436 & IEC 61000-3-2), door interlock, pressure/temperature monitoring, forced-air exhaust, overpressure relief |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MGS-M30 |
| Pricing | Upon Request |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MKX-R4HB |
| Price Range | USD 14,000 – 42,000 (FOB China) |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXN-W50 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | 0–100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Maximum Sample Volume per Cycle | 5 L |
| Total Throughput Capacity | 50–100 L (automated sequential concentration) |
| Microwave Output Power | 3200 W |
| Temperature Sensor | Thermocouple (±1 °C accuracy) |
| Evaporation Vessel | 5 L microwave-compatible ceramic-coated stainless steel dish |
| Cavity Material | Stainless steel with multi-layer PTFE coating |
| Exhaust System | Corrosion-resistant variable-frequency centrifugal blower (2.5 m³/min airflow) |
| Control System | PID controller or optional PLC-based touchscreen interface |
| Safety Interlock | Door-activated power cutoff with multi-layer RF leakage suppression |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKC-G1C1B |
| Instrument Type | High-Temperature Drying Oven |
| Temperature Range | 0–300 °C |
| Temperature Uniformity | ±1 °C |
| External Dimensions | 782 × 800 × 450 mm (W × H × D) |
| Cavity Material | 304 Stainless Steel, Seamless Welded Construction |
| Heating Method | Microwave Energy (2450 MHz) + Far-Infrared Radiant Heating |
| Microwave Output | 800 W, Continuous Non-Pulsed |
| Far-Infrared Power | 1500 W |
| Cavity Volume | ~20 L |
| Weighing Capacity | 1000 g |
| Weight Resolution | 0.01 g |
| Stirring Mechanism | Motorized Vertical Lift Stirrer (Φ100 mm Platform) |
| Safety Compliance | Microwave Leakage < 5 mW/cm² (IEC 61000-4-3 / GB 4706.21) |
| Control System | PLC-Based Touchscreen Interface with Data Logging |
| Power Supply | 220 V AC, 50 Hz |
| Total Power Consumption | 3000 W |
| Weight | 80 kg |
| Certification | ISO 9001 Certified |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Category | Domestic |
| Model | MW-3 |
| Instrument Type | Box-Type Muffle Furnace |
| Max Temperature | 0–1000 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 0–10 kW |
| Heating Rate to Max Temp | 40 min |
| Heating Method | Electric Resistance Heating |
| Internal Dimensions | 700 × 860 × 820 mm |
| Chamber Volume | 35 L |
| Temperature Sensor | Dual Platinum-Rhodium Thermocouples (Type S) |
| Airflow System | Multi-Port Uniform-Flow Through-Ventilation |
| Exhaust | Integrated Negative-Pressure Extraction with Adjustable Dampers |
| Control System | PLC-Based Closed-Loop PID Control with Color Touchscreen Interface |
| Safety Features | Interlocked Door Switch, Surface Temp <50 °C, Explosion-Resistant Casing, Corrosion-Resistant Interior Lining |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKM-CH1GA |
| Price Range | USD 14,000–28,000 (FOB) |
| Temperature Range | 0–500 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Reaction Units | 1 |
| Maximum Reaction Volume | 1 L |
| Microwave Source | Solid-State, 0–1000 W at 2450 MHz |
| VSWR | ≤5 |
| Cavity Material | Welded Stainless Steel, Positive-Pressure Sealed, Top-Opening Design |
| Cavity Volume | 1 L Annular Single-Mode Chamber with PTFE Coating |
| Reaction Vessels | Helical Tubing (PTFE or Borosilicate Glass) |
| Temperature Sensing | Radial Infrared (0–500 °C), Axial Fiber-Optic (0–300 °C, Optional) |
| Control System | PLC-Based Intelligent Controller with Color Touchscreen |
| Data Logging | Real-Time Temperature/Power Curves, Multi-Protocol Memory, USB Export |
| Atmosphere Control | Inlet/Outlet Gas Ports for Inert, Reducing, or Oxidizing Environments |
| Dimensions (W×D×H) | 615 × 450 × 500 mm |
| Brand | Makewave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKG-M5TB |
| Chamber Volume | Small-scale |
| Construction Material | Stainless Steel |
| Operating Pressure | Low-pressure |
| Capacity | 1 m³ |
| Vacuum Level | –0.098 Pa |
| Microwave Frequency | 2450 MHz |
| Microwave Power Output | 4 kW |
| Input Power Requirement | 3-phase, 380 V ±5%, 50 Hz |
| Total Electrical Load | ≥7.5 kVA |
| Internal Cavity Dimensions | 400 × 400 × 400 mm (W × H × D) |
| Borosilicate Glass Tube Dimensions | Horizontal section — 700 mm length × 230 mm OD |
| Microwave Leakage | <5 mW/cm² (per GB 10436-2008 / IEC 62233) |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MGX-J Series |
| Price Range | USD 21,000 – 42,500 (FOB) |
| Usable Volume | Large-scale (1000 L) |
| Construction Material | 304 Stainless Steel |
| Operating Pressure | Low-pressure (≤0.6 MPa gauge) |
| Vacuum Capability | Atmospheric operation only (no vacuum rating) |
| Frequency | 2450 MHz |
| Microwave Power Output | 8–50 kW (adjustable, industrial-grade frequency-variable magnetron source) |
| Auxiliary Electric Heating Power | 30–100 kW |
| Temperature Range | Ambient to 250 °C |
| Control Interface | PLC-based HMI touchscreen terminal |
| Compliance | GB 5959.6–2008, ISO 9001 certified |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKX-H2G1A |
| Price Range | USD 14,000 – 28,000 (FOB) |
| Temperature Range | 0–220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Reaction Volume | 40 L (cavity capacity) |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 1600 W (continuous, non-pulsed output) |
| Safety Leakage | <5 mW/cm² |
| Power Supply | 220 V AC / 50 Hz |
| Total Power Consumption | 3000 W |
| Net Weight | 80 kg |
| Dimensions (W×H×D) | 782 × 610 × 523 mm |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKZ-G2A |
| Instrument Type | Vacuum Drying Oven |
| Temperature Range | Ambient to 100 °C (infrared non-contact measurement) |
| Temperature Uniformity | ±1 °C |
| External Dimensions | 652 × 550 × 800 mm (W × H × D) |
| Internal Chamber Dimensions | 305 × 305 × 305 mm (W × H × D) |
| Chamber Material | AISI 304 Stainless Steel |
| Heating Method | 2450 MHz Microwave Energy |
| Microwave Power | 1600 W (industrial-grade variable-frequency generator) |
| Ultimate Vacuum | –0.099 MPa |
| Chamber Volume | 26 L |
| Power Supply | 220 VAC / 50 Hz |
| Total Power Consumption | 3000 W |
| Net Weight | 100 kg |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | MKX-E1G6A |
| Microwave Output Power | 800 W (continuous, non-pulsed) |
| Microwave Frequency | 2450 MHz |
| Temperature Control Range | 0–220 °C |
| Temperature Accuracy | ±1% of setpoint |
| Cavity Material | Seamless 304 stainless steel with multi-layer PTFE coating |
| Cavity Volume | ~20 L |
| Maximum Operating Pressure | 3 MPa |
| Sample Capacity | 6 × 80 mL parallel high-pressure extraction vessels |
| Power Supply | 220 V AC, 50 Hz |
| Total Power Consumption | 1300 W |
| Dimensions (W×H×D) | 782 × 492 × 450 mm |
| Weight | 65 kg |
| Safety Compliance | Microwave leakage < 5 mW/cm² (exceeding GB 10436-2008), ISO 9001 certified |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | MKX-H1C1M |
| Temperature Range | 0–300 °C |
| Pressure Rating | Atmospheric (Ambient Pressure) |
| Microwave Output Power | 0–900 W (Linear, Continuous, Non-Pulsed) |
| Magnetron Frequency | 2450 MHz |
| Stirring Method | Mechanical + Magnetic Stirring |
| Reaction Volume Capacity | 20 L |
| Ultrasonic Frequency | 28 kHz (Adjustable Range: 15–40 kHz) |
| Ultrasonic Power Output | 1000 W |
| Microwave Cavity Dimensions | 250 × 285 × 275 mm (W × H × D) |
| Overall Dimensions (Excl. Stand) | ~670 × 460 × 450 mm (W × H × D) |
| Microwave Leakage Level | <5 mW/cm² (Compliant with GB 10436–2008) |
| Control Interface | Touchscreen PLC-based System with USB Data Export |
| Temperature Sensing | Infrared Sensor (0–300 °C, ±1 °C Accuracy) |
| Input Power | 1200 W (220 V ±10%, 50 Hz ±1%) |
| Cavity Material | 304 Stainless Steel with PTFE Coating |
| External Housing | Powder-Coated Carbon Steel |
| Safety Features | Interlocked Door Switch, Microwave Shielding Structure, Over-Temperature & Over-Current Protection |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MKX-T4A |
| Instrument Type | Box-Type Furnace |
| Maximum Temperature | 1400 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Microwave Power | 3200 W at 2450 MHz |
| Heating Rate to Max Temp | ≤40 min |
| Heating Method | Microwave Energy |
| Internal Cavity Dimensions | 1360 mm (W) × 1600 mm (H) × 800 mm (D) |
| Cavity Volume | ~8 L |
| Power Supply | 220 V AC / 50 Hz |
| Total Power Consumption | 5200 W |
| Net Weight | 80 kg |
Show next