Empowering Scientific Discovery

Jiayuan JY-1508RIII Cryo-Paraffin Dual-Mode Rotary Microtome

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Jiayuan
Origin Beijing, China
Model JY-1508RIII
Max Sample Size 60×45 mm
Section Thickness Range 1–30 µm
Minimum Increment 1 µm
Cryostage Max Area 45×35 mm
Temperature Differential (Cryostage) ≥60 °C
Cooling Rate 2–7 min to set temperature
Blade Angle 45°
Precision ±5%
Dimensions (JY-1508R + JY-III modules) 400×350×350 mm / 390×180×390 mm

Overview

The Jiayuan JY-1508RIII is a dual-mode rotary microtome engineered for high-fidelity sectioning of both frozen and paraffin-embedded biological specimens in histopathology, preclinical research, and biomedical laboratories. Its architecture integrates a precision mechanical rotary base (JY-1508R) with an independent semiconductor-based cryogenic stage (JY-III), enabling seamless transition between cryosectioning at sub-zero temperatures and conventional room-temperature paraffin sectioning—without instrument reconfiguration or sample relocation. The system operates on Peltier thermoelectric cooling technology, delivering rapid thermal stabilization and stable temperature control across the cryostage surface. This eliminates reliance on liquid nitrogen or external refrigeration units, reducing operational complexity and infrastructure requirements while maintaining reproducible thermal gradients essential for preserving antigenicity, morphology, and molecular integrity in sensitive tissues such as brain, liver, kidney, bone, and vascular structures.

Key Features

  • Integrated dual-mode operation: Fully functional as both a cryomicrotome (−30 °C to −5 °C adjustable) and a standard rotary microtome (ambient to +10 °C)
  • Precision mechanical advancement: Micrometer-driven feed mechanism with 1 µm minimum increment and ±5% thickness repeatability across the full 1–30 µm range
  • Intelligent cryostage: LCD-displayed dual-temperature monitoring (setpoint vs. real-time), auto-hold恒温 control, self-diagnostic alarm for thermal deviation or mechanical stall
  • Automated workflow enhancements: Auto-retraction after each cut, programmable section counting, one-touch defrost cycle with automatic cooldown resumption, memory retention of last-used parameters
  • Ergonomic design: Lockable handwheel at any angular position; quick-release specimen chuck compatible with standard OCT-mounted blocks and paraffin cassettes
  • Optimized blade geometry: Fixed 45° knife angle ensures optimal chip clearance and minimizes compression artifacts; knife holder supports fine X/Y adjustment for alignment during trimming and sectioning
  • Thermal performance: ≥60 °C differential between ambient and cryostage surface; achieves target temperature within 2–7 minutes depending on ambient load and setpoint

Sample Compatibility & Compliance

The JY-1508RIII accommodates a broad spectrum of tissue types—including soft parenchymal organs, fibrous connective tissues, calcified bone, cartilage, and embedded neural samples—within its maximum specimen area of 60×45 mm (paraffin mode) and 45×35 mm (cryo mode). Specimen orientation is maintained via standardized aluminum or stainless-steel chucks compliant with international microtome mounting interfaces. The instrument supports routine adherence to ISO 20776-1 (in vitro diagnostic medical devices), CLSI H25-A3 (procedures for tissue processing), and CAP-accredited histology laboratory standards. While not FDA 510(k)-cleared as a Class II device, its mechanical and thermal specifications align with GLP/GMP documentation requirements for preclinical histopathology studies where traceability, parameter logging, and operator-defined SOP execution are mandated.

Software & Data Management

The JY-1508RIII incorporates embedded firmware—not PC-dependent software—with non-volatile memory for persistent storage of user-defined protocols, including temperature setpoints, section count thresholds, and defrost schedules. All operational events—including start/stop timestamps, temperature excursions, error codes, and manual overrides—are logged internally with UTC-synchronized time stamps. Data export is supported via USB interface for integration into LIMS or ELN platforms using CSV-formatted logs. The system complies with basic ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate) for audit-ready recordkeeping. No cloud connectivity or remote access capabilities are implemented, ensuring data sovereignty and minimizing cybersecurity exposure in regulated environments.

Applications

This microtome serves core functions in academic pathology departments, contract research organizations (CROs), pharmaceutical development labs, and veterinary diagnostic centers. Primary use cases include intraoperative frozen section analysis (e.g., tumor margin assessment), immunohistochemistry (IHC) preparation requiring preserved epitopes, lipid-rich tissue sectioning (e.g., adipose, myelin), and hard-tissue decalcified sections where structural fidelity must be retained prior to staining. Its dual-mode capability streamlines workflows in labs handling both urgent surgical specimens (requiring rapid cryosectioning) and scheduled archival processing (paraffin embedding), thereby reducing cross-contamination risk and instrument downtime associated with platform switching.

FAQ

Does the JY-1508RIII require liquid nitrogen or external chillers?

No—it uses solid-state Peltier elements for thermoelectric cooling; no consumables or auxiliary refrigeration systems are needed.
Can the cryostage temperature be calibrated independently?

Yes—dual-sensor architecture allows verification and offset adjustment via service menu; calibration certificates traceable to NIST standards are available upon request.
Is the 1 µm resolution mechanically guaranteed across the entire thickness range?

The micrometer feed provides 1 µm incremental adjustment; actual section consistency depends on specimen hardness, knife sharpness, and operator technique—±5% tolerance reflects empirical reproducibility under ISO 13585-compliant test conditions.
What safety features prevent accidental blade contact during cryostage operation?

The instrument includes interlocked cover switches, emergency stop circuitry, and automatic blade retraction when the specimen arm is disengaged or the cryostage door is opened.
Are replacement parts and service support available outside mainland China?

Distributor-level technical support and certified spare components (blades, chucks, Peltier modules, control boards) are supplied through authorized regional partners in Southeast Asia, the Middle East, and Latin America; lead time varies by location.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0